<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>Druckminderventile – ZECO Ventil</title>
	<atom:link href="https://zecovalve.com/de/tag/pressure-reducing-valves/feed" rel="self" type="application/rss+xml" />
	<link>https://zecovalve.com/de</link>
	<description>Industriekugelhahn, Schieber und Kugelhahn Hersteller</description>
	<lastbuilddate>Sa., 10. September 2022 13:14:31 +0000</lastbuilddate>
	<language>de</language>
	<sy:updateperiod>
	stündlich	</sy:updateperiod>
	<sy:updatefrequency>
	1	</sy:updatefrequency>
	<generator>https://wordpress.org/?v=6.9.4</generator>

<image>
	<url>https://zecovalve.com/wp-content/uploads/2024/09/ZECO-100x100.jpg</url>
	<title>Druckminderventile – ZECO Ventil</title>
	<link>https://zecovalve.com/de</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>AUTOMATISCHES STEUERVENTIL – Druckminderventil / Überdruckventil</title>
		<link>https://zecovalve.com/de/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html</link>
		
		<dc:creator><![CDATA[Jerry]]></dc:creator>
		<pubdate>Mi, 05. Januar 2022 07:45:19 +0000</pubdate>
				<category><![CDATA[Control Valve]]></category>
		<category><![CDATA[Altitude Control Valve]]></category>
		<category><![CDATA[Altitude Control Valves]]></category>
		<category><![CDATA[Automatic Control Valve]]></category>
		<category><![CDATA[Automatic Control Valves]]></category>
		<category><![CDATA[Float Control Valve]]></category>
		<category><![CDATA[Pressure Reducing Valve]]></category>
		<category><![CDATA[Pressure Reducing Valve Wikipedia]]></category>
		<category><![CDATA[Pressure Reducing Valves]]></category>
		<category><![CDATA[pressure relief valve]]></category>
		<category><![CDATA[Pressure Relief Valves]]></category>
		<category><![CDATA[Pressure Safety Valve Market]]></category>
		<category><![CDATA[Shanghai Pressure Reducing Valve Factory]]></category>
		<category><![CDATA[Surge Anticipating Valve]]></category>
		<category><![CDATA[Valves used in Oertli Lane]]></category>
		<guid ispermalink="false">https://zecovalve.com/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html</guid>

					<description><![CDATA[<p>Regelventile sind ein entscheidender Bestandteil des effizienten und effektiven Betriebs eines Rohrleitungssystems. Was sind automatische Regelventile? ... <a title="AUTOMATISCHES STEUERVENTIL – Druckminderventil / Überdruckventil" class="read-more" href="https://zecovalve.com/de/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html" aria-label="Mehr zu AUTOMATISCHES REGELVENTIL – Druckminderventil / Druckbegrenzungsventil">Weiterlesen ...</a></p>
<p>The post <a rel="nofollow" href="https://zecovalve.com/de/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html">AUTOMATIC CONTROL VALVE &#8211; Pressure Reducing Valve / Pressure Relief Valve</a> appeared first on <a rel="nofollow" href="https://zecovalve.com/de">ZECO Valve</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p> Regelventile sind ein entscheidender Bestandteil des effizienten und effektiven Betriebs eines Rohrleitungssystems.</p>


<nav class="wp-block-kadence-tableofcontents kb-table-of-content-nav kb-table-of-content-id_20ac17-72" role="navigation" aria-label="Inhaltsverzeichnis"><div class="kb-table-of-content-wrap"><div class="kb-table-of-contents-title-wrap kb-toggle-icon-style-arrow"><span class="kb-table-of-contents-title">Inhaltsübersicht</span></div><ul class="kb-table-of-content-list kb-table-of-content-list-columns-1 kb-table-of-content-list-style-disc kb-table-of-content-link-style-underline"><li><a class="kb-table-of-contents__entry" href="#h-what-are-automatic-control-valves">Was sind automatische Regelventile?</a></li><li><a class="kb-table-of-contents__entry" href="#h-how-does-an-automatic-control-valve-work">Wie funktioniert ein automatisches Steuerventil?</a><ul class="kb-table-of-contents-list-sub"><li><a class="kb-table-of-contents__entry" href="#h-principle-of-automatic-control-valves-for-on-off-operation">Prinzip automatischer Regelventile für den Ein-/Aus-Betrieb</a><ul class="kb-table-of-contents-list-sub"><li><a class="kb-table-of-contents__entry" href="#h-valve-opening">Ventilöffnung</a></li><li><a class="kb-table-of-contents__entry" href="#h-valve-isolated-from-the-line">Von der Leitung isoliertes Ventil</a></li><li><a class="kb-table-of-contents__entry" href="#h-valve-closing">Ventil schließen</a></li></ul></li><li><a class="kb-table-of-contents__entry" href="#h-principle-of-automatic-control-valves-for-modulating-operation">Prinzip automatischer Regelventile für modulierenden Betrieb</a><ul class="kb-table-of-contents-list-sub"><li><a class="kb-table-of-contents__entry" href="#h-valve-opening-1">Ventilöffnung</a></li><li><a class="kb-table-of-contents__entry" href="#h-valve-modulating">Ventilmodulation</a></li><li><a class="kb-table-of-contents__entry" href="#h-valve-closing-1">Ventil schließen</a></li></ul></li></ul></li><li><a class="kb-table-of-contents__entry" href="#h-components-of-an-automatic-control-valve">Komponenten eines automatischen Regelventils</a></li><li><a class="kb-table-of-contents__entry" href="#h-applications-of-automatic-control-valves">Anwendungen von automatischen Regelventilen</a></li><li><a class="kb-table-of-contents__entry" href="#h-types-of-automatic-control-valves">Arten von automatischen Regelventilen</a><ul class="kb-table-of-contents-list-sub"><li><a class="kb-table-of-contents__entry" href="#h-pressure-reducing-valves">Druckminderventile</a></li><li><a class="kb-table-of-contents__entry" href="#h-pressure-relief-valves">Druckentlastungsventile</a></li><li><a class="kb-table-of-contents__entry" href="#h-altitude-control-valves">Höhenkontrollventile</a></li><li><a class="kb-table-of-contents__entry" href="#h-remote-float-control-valves">Ferngesteuerte Schwimmerventile</a></li><li><a class="kb-table-of-contents__entry" href="#h-surge-anticipating-valves">Überspannungsschutzventile</a></li><li><a class="kb-table-of-contents__entry" href="#h-solenoid-control-valves">Magnetventile</a></li><li><a class="kb-table-of-contents__entry" href="#h-flow-control-valves">Durchflussregelventile</a></li></ul></li><li><a class="kb-table-of-contents__entry" href="#h-advantages-of-automatic-control-valves">Vorteile automatischer Regelventile</a></li></ul></div></nav>


<h2 class="wp-block-heading" id="h-what-are-automatic-control-valves">Was sind <strong><mark style="background-color:var(--base)" class="has-inline-color has-contrast-2-color"><a href="https://zecovalve.com/de/produktkategorie/water-control-valve/" target="_blank" rel="noreferrer noopener">Automatische Regelventile</a></mark></strong>?</h2>



<p>Automatische Regelventile gemäß EN 1074-5: „verfügen über die integrierte Fähigkeit, die Funktion durch Energiezufuhr aus dem geförderten Wasser durch Anpassung der Position des Verschlusses zu steuern. Sie können direkt gesteuert werden, d. h. die Kraft wird (über eine Feder oder Membran) direkt auf den Verschluss ausgeübt. Sie können vorgesteuert werden, d. h. die Kraft wird über ein einstellbares Vorsteuerventil ausgeübt.“</p>



<h2 class="wp-block-heading" id="h-how-does-an-automatic-control-valve-work">Wie funktioniert ein automatisches Steuerventil?</h2>



<figure class="wp-block-image size-large"><img fetchpriority="high" decoding="async" width="1024" height="367" src="https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-1-1024x367.png" alt="" class="wp-image-16734" srcset="https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-1-1024x367.png 1024w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-1-300x108.png 300w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-1-768x275.png 768w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-1-600x215.png 600w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-1.png 1512w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<h3 class="wp-block-heading" id="h-principle-of-automatic-control-valves-for-on-off-operation">Prinzip automatischer Regelventile für den Ein-/Aus-Betrieb</h3>



<h4 class="wp-block-heading" id="h-valve-opening">Ventilöffnung</h4>



<p>Wenn der Druck in der Steuerkammer mit der Atmosphäre oder einer anderen Zone mit niedrigerem Druck in Verbindung gebracht wird, wirkt der Druck stromaufwärts auf den Verschluss und drückt ihn nach oben, wodurch die vollständige Öffnung des Ventils ermöglicht wird.</p>



<h4 class="wp-block-heading" id="h-valve-isolated-from-the-line">Von der Leitung isoliertes Ventil</h4>



<p>Sollte die Steuerkammer vom Leitungsdruck und dem Rest der Schaltung isoliert sein, bleibt das Ventil in derselben Position und erzeugt daher den Druckverlust, der diesem Öffnungsprozentsatz entspricht.</p>



<h4 class="wp-block-heading" id="h-valve-closing">Ventil schließen</h4>



<p>Wenn die Steuerkammer mit dem Vordruck in Verbindung gebracht wird, schließt das Ventil dank des Flächenunterschieds zwischen der oberen Abflachung mit der Membran, der größer ist als der darunterliegende Verschluss, vollständig.</p>



<figure class="wp-block-image size-large"><img decoding="async" width="1024" height="385" src="https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-2-1024x385.png" alt="" class="wp-image-16735" srcset="https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-2-1024x385.png 1024w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-2-300x113.png 300w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-2-768x288.png 768w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-2-600x225.png 600w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-principle-2.png 1507w" sizes="(max-width: 1024px) 100vw, 1024px" /></figure>



<h3 class="wp-block-heading" id="h-principle-of-automatic-control-valves-for-modulating-operation">Prinzip automatischer Regelventile für modulierenden Betrieb</h3>



<h4 class="wp-block-heading" id="h-valve-opening-1">Ventilöffnung</h4>



<p>Wenn das Hauptventil modulieren muss, ist zusätzlich zu einem Regler (F) im Kreislauf eine Drossel (R) zwischen dem vorgeschalteten Leitungsdruck und der Steuerkammer erforderlich. Sollte letzterer vollständig geöffnet werden, wird der Druck in der Steuerkammer mit dem nachgeschalteten Druck verbunden, wodurch das vollständige Öffnen des Hauptventils ermöglicht wird.</p>



<h4 class="wp-block-heading" id="h-valve-modulating">Ventilmodulation</h4>



<p>Wenn der Durchflussregler (F) gedrosselt wird, baut sich zwischen ihm und der Steuerkammer ein Druck auf, der das Ventil in eine Zwischenposition steuert. Dies wird durch den Druckunterschied erreicht, der durch die Drosselung (R) entsteht, und durch den Unterschied im Querschnitt zwischen der oberen Abflachung, die auf die Membran einwirkt, und dem Verschluss.</p>



<h4 class="wp-block-heading" id="h-valve-closing-1">Ventil schließen</h4>



<p>Sollte der Durchflussregler (F) vollständig geschlossen sein, wird der gesamte Druck in der vorgeschalteten Leitung in die Hauptsteuerkammer umgeleitet. Der bewegliche Block wird durch die auf die obere Membran ausgeübte Kraft bewegt und drückt das Verschlusselement flach auf den Sitz, wodurch der Durchfluss durch das Hauptventil unterbrochen wird.</p>



<h2 class="wp-block-heading" id="h-components-of-an-automatic-control-valve">Komponenten eines automatischen Regelventils</h2>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img decoding="async" width="735" height="862" src="https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve.png" alt="" class="wp-image-16736" srcset="https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve.png 735w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-256x300.png 256w, https://zecovalve.com/wp-content/uploads/2022/06/Zeco-Control-Valve-600x704.png 600w" sizes="(max-width: 735px) 100vw, 735px" /></figure>
</div>


<h2 class="wp-block-heading" id="h-applications-of-automatic-control-valves">Anwendungen von automatischen Regelventilen</h2>



<ul class="wp-block-list"><li>Wasseraufbereitungsanlagen</li><li>Mehrstöckige Gebäude</li><li>Wasserspeichertürme</li><li>Aufbereitungsanlagen für Wasser</li><li>HVAC-Systeme</li></ul>



<h2 class="wp-block-heading" id="h-types-of-automatic-control-valves">Arten von automatischen Regelventilen</h2>



<h3 class="wp-block-heading" id="h-pressure-reducing-valves"><strong><mark style="background-color:var(--base)" class="has-inline-color has-contrast-2-color"><a href="https://zecovalve.com/de/produkt/pressure-reducing-valve/" target="_blank" rel="noreferrer noopener">Druckminderventile</a></mark></strong></h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/pressure-reducing-valve.jpg" alt="" class="wp-image-16737" srcset="https://zecovalve.com/wp-content/uploads/2022/06/pressure-reducing-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/pressure-reducing-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption><a href="https://zecovalve.com/de/water-pressure-reducing-valve-manufacturer-zeco-valve.html/" data-internallinksmanager029f6b8e52c="8" title="Druckreduzierventil" target="_blank" rel="noopener">Druckreduzierventil</a></figcaption></figure>
</div>


<p>Druckminderventile können einen höheren Eingangsdruck unabhängig von Druckschwankungen bei Bedarf und Versorgung auf einen konstanten Ausgangsdruck reduzieren und ermöglichen die Lieferung von Wasser mit sicherem Druck und in ausreichender Menge für den Kundenbedarf.</p>



<h3 class="wp-block-heading" id="h-pressure-relief-valves"><strong><a href="https://zecovalve.com/de/produkt/pressure-relief-valve/" target="_blank" rel="noreferrer noopener">Druckentlastungsventile</a></strong></h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/pressure-relief-valve.jpg" alt="" class="wp-image-16738" srcset="https://zecovalve.com/wp-content/uploads/2022/06/pressure-relief-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/pressure-relief-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption>Druckbegrenzungsventil</figcaption></figure>
</div>


<p>Ein Überdruckventil kann überschüssigen Druck ablassen und gleichzeitig einen Mindestdruck stromaufwärts aufrechterhalten und verhindern, dass die Nachfrage stromabwärts die Versorgung einer stromaufwärts gelegenen Zone beeinträchtigt.</p>



<h3 class="wp-block-heading" id="h-altitude-control-valves"><strong><a href="https://zecovalve.com/de/produkt/altitude-control-valve/" target="_blank" rel="noreferrer noopener">Höhenkontrollventile</a></strong></h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/altitude-control-valve.jpg" alt="" class="wp-image-16739" srcset="https://zecovalve.com/wp-content/uploads/2022/06/altitude-control-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/altitude-control-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption>Höhenregelventil</figcaption></figure>
</div>


<p>Das Höhenregelventil ist so konzipiert, dass es sich öffnet und den Durchfluss in ein Reservoir oder einen erhöhten Lagertank (Tankfüllung) ermöglicht, und sich tropffrei schließt, wenn ein hoher Wasserstand erreicht wird. Es regelt den Wasserstand durch Fernmessung des statischen Tankkopfdrucks über eine vor Ort installierte Sensorleitung, öffnet sich, wenn der Wasserstand unter dem einstellbaren Sollwert liegt, und schließt tropffrei, wenn der Pegel über dem einstellbaren Sollwert liegt.</p>



<h3 class="wp-block-heading" id="h-remote-float-control-valves"><strong><a href="https://zecovalve.com/de/produkt/modulating-float-valve/" target="_blank" rel="noreferrer noopener">Ferngesteuerte Schwimmerventile</a></strong></h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/modulating-float-valve.jpg" alt="" class="wp-image-16740" srcset="https://zecovalve.com/wp-content/uploads/2022/06/modulating-float-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/modulating-float-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption>Ferngesteuertes Schwimmersteuerventil</figcaption></figure>
</div>


<p>Das ferngesteuerte Schwimmersteuerventil ist so konzipiert, dass es tropffrei schließt, wenn der Wasserstand den einstellbaren Hochpegelsollwert erreicht, und sich vollständig öffnet, wenn der Wasserstand unter dem einstellbaren Niedrigpegelsollwert liegt, um die Zirkulation im Tank zu erhöhen. Hohe und niedrige Pegelstände sind separat einstellbar, indem Anschlagmanschetten an den Schwimmerstangen an den gewünschten Öffnungs- und Schließsollwerten positioniert werden. Falls gewünscht, kann die Ein-/Aus-Funktion des Ventils umgekehrt werden, indem die Hydraulikanschlüsse des Ein-/Aus-Schwimmerpiloten geändert werden. Der Schwimmerpilot kann entweder am Ventil oder ferngesteuert montiert sein.</p>



<h3 class="wp-block-heading" id="h-surge-anticipating-valves"><strong><a href="https://zecovalve.com/de/produkt/surge-anticipating-valve/" target="_blank" rel="noreferrer noopener">Überspannungsschutzventile</a></strong></h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/surge-anticipating-valve.jpg" alt="" class="wp-image-16741" srcset="https://zecovalve.com/wp-content/uploads/2022/06/surge-anticipating-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/surge-anticipating-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption>Überspannungsschutzventil</figcaption></figure>
</div>


<p>Das Überspannungsschutzventil ist ein Offline-Ventil mit hydraulischer Membranbetätigung. Das Ventil erkennt den Leitungsdruck und öffnet sich als Reaktion auf den Druckabfall, der durch einen plötzlichen Pumpenstopp verursacht wird. Das vorgeöffnete Ventil leitet die zurückkehrende Hochdruckwelle ab und beseitigt den Überdruck. Das Überspannungsschutzventil schließt sanft und tropffrei, sobald die Entlastungsfunktion dies zulässt, und verhindert gleichzeitig einen Schließdruckstoß. Das Ventil entlastet auch übermäßigen Systemdruck.</p>



<h3 class="wp-block-heading" id="h-solenoid-control-valves">Magnetventile</h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/solenoid-control-valve.jpg" alt="" class="wp-image-16742" srcset="https://zecovalve.com/wp-content/uploads/2022/06/solenoid-control-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/solenoid-control-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption>Magnetsteuerventil</figcaption></figure>
</div>


<p>Wassermagnetventile sind die am häufigsten eingesetzten Steuerelemente in der Fluidik. Ihre Aufgaben sind das Absperren, Freigeben, Dosieren, Verteilen oder Mischen von Fluiden. Sie finden sich in vielen Anwendungsbereichen wieder. Magnetventile bieten schnelles und sicheres Schalten, hohe Zuverlässigkeit, lange Lebensdauer, gute Medienverträglichkeit der eingesetzten Werkstoffe, geringe Steuerleistung und kompakte Bauweise.</p>



<h3 class="wp-block-heading" id="h-flow-control-valves"><strong><a href="https://zecovalve.com/de/produkt/solenoid-control-valve/" target="_blank" rel="noreferrer noopener">Durchflussregelventile</a></strong></h3>


<div class="wp-block-image">
<figure class="aligncenter size-full"><img loading="lazy" decoding="async" width="330" height="300" src="https://zecovalve.com/wp-content/uploads/2022/06/flow-control-valve.jpg" alt="" class="wp-image-16743" srcset="https://zecovalve.com/wp-content/uploads/2022/06/flow-control-valve.jpg 330w, https://zecovalve.com/wp-content/uploads/2022/06/flow-control-valve-300x273.jpg 300w" sizes="auto, (max-width: 330px) 100vw, 330px" /><figcaption>Durchflussregelventil</figcaption></figure>
</div>


<p>Das Durchflussregelventil verhindert einen übermäßigen Durchfluss, indem es den Durchfluss auf eine voreingestellte Maximalrate begrenzt, unabhängig vom sich ändernden Leitungsdruck. Es handelt sich um hydraulisch betriebene, vorgesteuerte Membranventile. Die Vorsteuerung reagiert auf den Differenzdruck, der über einer nachgeschalteten Blende erzeugt wird. Eine genaue Steuerung ist gewährleistet, da sehr kleine Änderungen des steuernden Differenzdrucks eine sofortige Korrekturmaßnahme des Hauptventils bewirken. Die Durchflussratenanpassung erfolgt durch Drehen einer Einstellschraube an der Vorsteuerung.</p>



<h2 class="wp-block-heading" id="h-advantages-of-automatic-control-valves">Vorteile automatischer Regelventile</h2>



<ul class="wp-block-list"><li>Durchgehendes radiales Stromliniendesign, geringer Flüssigkeitswiderstand, großer Durchfluss und starke Antikavitationsfähigkeit.</li><li>Der Dichtungsring verfügt über eine fortschrittliche sternförmige Dichtungsringstruktur.</li><li>Abnehmbarer Ventilsitz aus Edelstahl 304, Korrosionsbeständigkeit, Erosionsbeständigkeit, gute Dichtleistung.</li><li>Die Membran besteht aus nylonverstärktem Gummi mit dreidimensionalem Netz, guter Elastizität, hoher Druckbeständigkeit und langer Lebensdauer.</li><li>Zum Erreichen unterschiedlicher Funktionen stehen unterschiedliche Pilotventile zur Verfügung.</li><li>Druckbewertung: 10 bar, 16 bar, 25 bar; CL150, CL300</li><li>Endanschlüsse: Standardflanschenden gemäß EN1092, ASME B16.5 und andere auf Anfrage.</li></ul>



<!-- Andy:h-related-tags -->
<h2 id="h-related-tags">Verwandte Tags:</h2>
<!-- /Andy:h-related-tags -->



<div class="re_main">
<a href="https://zecovalve.com/de/">ZECO-Ventil</a>

</div>



<div class="re_main">
<a href="https://zecovalve.com/de/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html">Was sind automatische Regelventile?</a>

</div>



<div class="re_main">
<a href="https://zecovalve.com/de/introduction-of-epdm-nbr-butterfly-valve-seat-industrial-valve-information-news-zeco-valve.html/">NBR-Absperrklappe</a>

</div>



<div class="re_main">
<a href="https://zecovalve.com/de/what-is-an-axial-flow-silent-check-valve.html/">Was ist ein Axialrückschlagventil</a>

</div>




<div class="re_main">
<a href="https://zecovalve.com/de/produkt/manual-gate-valve/">Hersteller von manuell betätigten Absperrschiebern</a>

</div>



<div class="re_main">
<a href="https://zecovalve.com/de/tag/shanghai-pressure-reducing-valve-factory/">Shanghai Druckminderventilfabrik</a>

</div>



<p></p>



<p>Zehn Artikel davor und danach</p>



<p><a href="https://zecovalve.com/de/select-control-valves-i-zeco-valve-industrial-valve-manufacturer.html/">REGELVENTILE AUSWÄHLEN I – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/vertical-or-horizontal-inline-pump-design-which-to-select-zeco-valve-industrial-valve-manufacturer.html/">VERTIKALE ODER HORIZONTAL INLINE-PUMPENAUSFÜHRUNG – WELCHE SOLL MAN WÄHLEN – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/how-you-can-select-control-valves-ii-zeco-valve-industrial-valve-manufacturer.html/">SO WÄHLEN SIE REGELVENTILE II – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/use-and-maintenance-of-ball-valves-used-for-gas-pipes-zeco-valve-api-approved-valve-manufacturer.html/">Verwendung und Wartung von Kugelhähnen für Gasleitungen – Zeco Valve | API-zugelassener Ventilhersteller</a></p>



<p><a href="https://zecovalve.com/de/how-you-can-select-end-suction-pumps-zeco-valve-industrial-valve-manufacturer.html/">SO WÄHLEN SIE EINE END-SUGHUMPE – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/good-reputation-for-split-case-pumps-zeco-valve-industrial-valve-manufacturer.html/">GUTER RUF FÜR SPLIT-CASE-PUMPEN – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/let-us-discuss-air-operated-diaphragm-pumps-zeco-valve-industrial-valve-manufacturer.html/">LASSEN SIE UNS ÜBER LUFTBETRIEBENE MEMBRANPUMPEN DISKUTIEREN – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/history-of-safety-valves-on-hands-fired-boilers-zeco-valve-industrial-valve-manufacturer.html/">GESCHICHTE DER SICHERHEITSVENTILE AN HANDBEHEIZTEN KESSELN – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/a-brief-history-of-metering-pumps-zeco-valve-industrial-valve-manufacturer.html/">EINE KURZE GESCHICHTE DER DOSIERPUMPEN – Zeco Valve | Hersteller von Industrieventilen</a></p>



<p><a href="https://zecovalve.com/de/the-foundation-from-the-pressure-relief-valve-zeco-valve-industrial-valve-manufacturer.html/">DIE GRUNDLAGE DES DRUCKENTLASTUNGSVENTILS – Zeco Valve | Hersteller von Industrieventilen</a></p><p>The post <a rel="nofollow" href="https://zecovalve.com/de/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html">AUTOMATIC CONTROL VALVE &#8211; Pressure Reducing Valve / Pressure Relief Valve</a> appeared first on <a rel="nofollow" href="https://zecovalve.com/de">ZECO Valve</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>