{"id":15586,"date":"2022-01-20T08:26:39","date_gmt":"2022-01-20T08:26:39","guid":{"rendered":"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html"},"modified":"2022-08-08T14:11:39","modified_gmt":"2022-08-08T14:11:39","slug":"climate-targets-api-approved-valve-manufacturer","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/climate-targets-api-approved-valve-manufacturer.html","title":{"rendered":"ZECO DBB Ventil \u2013 INTEC Duoball Ventil | Doppelblock- und Entl\u00fcftungsventil"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Was ist ein DBB-Ventil?<\/h2>\n\n\n\n<p>In den USA gibt es zwei Stellen, die DBB definieren: API und OSHA. Laut API ist ein DBB-Ventil ein \u201eEinzelventil mit zwei Sitzfl\u00e4chen, das in geschlossener Stellung eine Abdichtung gegen Druck von beiden Enden des Ventils bietet und \u00fcber eine M\u00f6glichkeit verf\u00fcgt, den Hohlraum zwischen den Sitzfl\u00e4chen zu entl\u00fcften.\u201c API weist in dieser Definition auch darauf hin, dass dieses Ventil keine positive doppelte Isolierung bietet, wenn nur eine Seite unter Druck steht.<\/p>\n\n\n\n<p>Im Gegensatz dazu beschreibt OSHA DBB als \u201edas Schlie\u00dfen einer Leitung, eines Kanals oder Rohrs durch Schlie\u00dfen und Verriegeln oder Markieren von zwei Inline-Ventilen und durch \u00d6ffnen und Verriegeln oder Markieren eines Ablass- oder Entl\u00fcftungsventils in der Leitung zwischen den beiden geschlossenen Ventilen.\u201c<\/p>\n\n\n\n<p>Die DBB-Definition von API erreicht nicht denselben Grad an Isolation wie die von OSHA. API erlaubt DBB-Ventile als ein einzelnes Ventil mit zwei unidirektionalen Sitzen, w\u00e4hrend der OSHA-Standard nur mit zwei separaten Ventilen und einer Methode zum Druckentlasten dazwischen erreicht werden kann. Es gibt einige Ventile, die ein Doppelventildesign verwenden. Durch die Kombination zweier Ventile in einem K\u00f6rper reduziert ein Doppelventildesign das Gewicht und potenzielle Leckagepfade und erf\u00fcllt gleichzeitig die OSHA-Anforderungen f\u00fcr Doppelblockierung und -entl\u00fcftung.<\/p>\n\n\n\n<p>Ventilverb\u00e4nde folgen normalerweise entweder der Definition von API oder OSHA, manche haben jedoch ein eigenes Handbuch mit eigenen Definitionen f\u00fcr Fachbegriffe erstellt. Die British Valve and Actuator Association (BVAA) definiert beispielsweise DBB als \u201eeinen Verteiler, der ein oder mehrere Absperrventile, normalerweise Kugelh\u00e4hne, und ein oder mehrere Entl\u00fcftungs-\/Entl\u00fcftungsventile, normalerweise ein Nadelventil, in einer Baugruppe zur Verbindung mit anderen Komponenten (z. B. Druckmessumformern, Druckmessern und Schaltern) kombiniert.\u201c<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Wie funktioniert das DBB-Ventil?<\/h2>\n\n\n\n<p>Zwei Blockventile sorgen f\u00fcr die Isolierung von den vor- und nachgelagerten Str\u00f6mungen. Als Blockventile werden normalerweise eine Reihe von Schieber-, Kugel-, Nadel- oder Durchgangsventilen verwendet, die R\u00fccken an R\u00fccken angeordnet sind. Im mittleren Hohlraum der beiden Blockventile befindet sich ein drittes Ventil, das als Entl\u00fcftungsventil bezeichnet wird.<\/p>\n\n\n\n<p>Die gleiche Doppelblock- und Entl\u00fcftungsanordnung kann mit drei separaten Ventilen erreicht werden. Das Doppelblock- und Entl\u00fcftungsventil mit einer einzigen Einheit spart jedoch enorm viel Platz, Gewicht, Installationszeit und Kosten. Auch aus Sicht des Betriebs und der Wartung sind Doppelblock- und Entl\u00fcftungsventile mit einer einzigen Einheit besser, da potenzielle Leckagepfade in einer einzigen Einheit erheblich reduziert sind. Der Druckabfall wird ebenfalls minimiert.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Merkmale des DBB-Ventils<\/h2>\n\n\n\n<p>Durch die strategische Integration von DBBs in ein Prozesssystem erh\u00f6hen Sie die Systemintegrit\u00e4t und verk\u00fcrzen die Wartungszeiten. Die wichtigsten Vorteile eines DBB-Ventils sind:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Erh\u00f6ht die Sicherheit und beschleunigt die Durchf\u00fchrung von Wartungs- und Reparaturvorg\u00e4ngen.<\/li><li>DBB-Ventile sind dicht verschlossen, um jegliche Leckagen zu verhindern.<\/li><li>DBB-Ventile sind best\u00e4ndig gegen Vibrationen und Druckschwankungen und verf\u00fcgen \u00fcber antistatische und ausblassichere Funktionen.<\/li><li>Zur Unterst\u00fctzung von DBB-Ventilen ist keine Verwendung von Halterungen erforderlich, da sie als Einzeleinheit konzipiert sind und mit den Prozessrohren verschraubt oder verschraubt werden k\u00f6nnen.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Unterschiede zwischen DIB und DBB<\/h2>\n\n\n\n<p>Bei einem DBB-Ventil gibt es normalerweise zwei unidirektionale, selbstentlastende Ventilsitze. Diese Ventilsitze sind nicht auf einen externen Mechanismus zur Druckentlastung angewiesen. Im Gegensatz dazu verwendet ein DIB-Ventil einen oder zwei bidirektionale Ventilsitze. Das Ventil bietet eine doppelte Druckisolierung an beiden Enden des Ventils, kann jedoch den Druck in der K\u00f6rperh\u00f6hle hinter den Ventilsitzen nicht entlasten. DIB-Ventile erfordern ein externes Entlastungssystem, um den Druckaufbau abzubauen.<\/p>\n\n\n\n<p>Beide Ventile k\u00f6nnen sowohl in stromaufw\u00e4rts als auch in stromabw\u00e4rts gerichteter Richtung eine Isolierung bieten, selbst bei hohem Druck oder hohen Temperaturen. Die Isolierung ist in F\u00e4llen wichtig, in denen ein Leck durch ein Ventil schwerwiegende Folgen haben k\u00f6nnte. Sobald die Fl\u00fcssigkeit isoliert ist, kann der Entl\u00fcftungsmechanismus den Bereich zwischen den beiden Ventilen oder den beiden Sitzfl\u00e4chen entleeren. Dies ist wichtig f\u00fcr Wartungs- und Integrit\u00e4tspr\u00fcfungssituationen, in denen Leckagen \u00fcberwacht werden k\u00f6nnen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Was ist ein INTEC Duo-Kugelhahn?<\/h2>\n\n\n\n<p>Gerade in zunehmend sicherheitskritischen Anwendungen sind Ventile mit \u201eDouble Block and Bleed\u201c-Funktion gefragt. Erf\u00fcllt wird diese Anforderung durch Kugelh\u00e4hne mit beidseitig kugelgelagerten und federbelasteten Kugelsitzen (Double Block) und einem Entl\u00fcftungs- bzw. Entleerungsanschluss (Bleed) im sogenannten Totraum.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Der Duoball-Kugelhahn verf\u00fcgt \u00fcber eine Doppelsperre und eine unabh\u00e4ngige Absperrung.<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Im Vergleich zu Standard-Kugelh\u00e4hnen kann die Sicherheit um den Faktor 4 erh\u00f6ht werden.<\/li><li>Die Konstruktion basiert auf der Integration zweier Kugelh\u00e4hne in einem K\u00f6rper.<\/li><li>Wie alle Kugelh\u00e4hne der INTEC-Serie ist der Duoball-Hahn mit schwimmender oder zapfengelagerter Kugel sowie in weich- oder metallisch dichtender Ausf\u00fchrung erh\u00e4ltlich.<\/li><li>Alle Kugelsitzsysteme erf\u00fcllen selbstverst\u00e4ndlich die Leckrate A nach EN 12266 und sind absolut gasdicht.<\/li><li>Durch die doppelte Isolierung und Entl\u00fcftungsfunktion ist jeder Duoball-Hahn beidseitig dicht.<\/li><li>Dar\u00fcber hinaus ist der Duoball Hahn auch in der genormten Baul\u00e4nge nach EN 588 R1 erh\u00e4ltlich und bietet neben der Erh\u00f6hung der Sicherheit eine kompakte und kosteng\u00fcnstige Alternative zur Verwendung mehrerer Standardarmaturen.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-intec-duoball-valves-and-co2-gas-carbon-dioxide-gas\">INTEC Duoball-Ventile und CO2-Gas (Kohlendioxidgas).<\/h2>\n\n\n\n<p>F\u00fcr Industrieunternehmen besteht die Anforderung, zur Einhaltung der Klimaziele das CO2 zu isolieren, zu transportieren, sicher zu lagern oder weiterzuverarbeiten.<sub>2<\/sub> erzeugtes Gas (Kohlendioxidgas).<\/p>\n\n\n\n<p>Der CO<sub>2 <\/sub>Die Abscheidung und Speicherung wird als Carbon Capture and Storage (CCS) und die Nutzung als Carbon Capture and Utilization (CCU) bezeichnet. Hierzu werden die Kugelh\u00e4hne Typ Duoball Nennweite DN32 mit einem Kugelhahn als Entl\u00fcftungsventil eingesetzt, um den Druck des definierten kleinstm\u00f6glichen Spalts der doppelten und unabh\u00e4ngigen Absperrung im Anschluss zu entlasten.<\/p>\n\n\n\n<p>Dadurch wird ein erheblicher Beitrag zu den Gesamtbetriebskosten durch optimierte OPEX und CAPEX erzielt.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Verwandte Tags:<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/\">ZECO-Ventil<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/produktkategorie\/ball-valve\/\">Kugelhahnhersteller \u2013 Verschiedene Kugelhahntypen<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/what-is-the-difference-between-floating-ball-valve-and-trunnion-mounted-ball-valve.html\/\">Unterschied zwischen schwimmendem Kugelhahn und Zapfenkugelhahn<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/the-difference-between-globe-valve-and-ball-valve.html\/\">Durchgangsventil vs. Kugelhahn<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/difference-between-gate-valves-and-ball-valves.html\/\">Schieberventil vs. Kugelhahn<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/thermoplastic-materials-as-valve-seat.html\/\">Thermoplastische Materialien als Kugelhahnsitz und Absperrklappensitz<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/the-difference-between-globe-valve-and-ball-valve.html\/\">Durchgangsventil vs. Kugelhahn<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/produkt\/12-inch-gate-valve\/\">12-Zoll-Schieberventillieferant<\/a>\n\n<\/div>\n\n\n\n<p>Zehn Artikel davor und danach<\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/spring-closing-unit-api-approved-valve-manufacturer.html\/\">Federschlie\u00dfeinheit | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/repair-api-approved-valve-manufacturer.html\/\">Reparatur | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/space-saving-installation-api-approved-valve-manufacturer.html\/\">Platzsparende Installation | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/realized-and-lived-sustainability-api-approved-valve-manufacturer.html\/\">Realisierte und gelebte Nachhaltigkeit | API zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/tert-butylamine-tba-api-approved-valve-manufacturer.html\/\">tert-Butylamin (tBA) | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/diol-plant-api-approved-valve-manufacturer.html\/\">Diolanlage | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/polymer-melt-api-approved-valve-manufacturer.html\/\">Polymerschmelze | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/high-pressure-ball-valves-api-approved-valve-manufacturer.html\/\">Hochdruck-Kugelh\u00e4hne | API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/covid-19-update-api-approved-valve-manufacturer.html\/\">API-zugelassener Ventilhersteller<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/de\/intec-duoball-valve-api-approved-valve-manufacturer.html\/\">INTEC Duoball Ventil | API zugelassener Ventilhersteller<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Was ist ein DBB-Ventil? In den USA gibt es zwei Stellen, die DBB definieren: API und OSHA. Laut API ist ein DBB \u2026 <a title=\"ZECO DBB Ventil \u2013 INTEC Duoball Ventil | Doppelblock- und Entl\u00fcftungsventil\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/climate-targets-api-approved-valve-manufacturer.html\" aria-label=\"Mehr zu ZECO DBB Ventil \u2013 INTEC Duoball Ventil | Doppelblock- und Entl\u00fcftungsventil\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2142,3276,2141,3278,3277],"class_list":["post-15586","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-dbb-valve","tag-dbb-valves","tag-double-block-and-bleed-valve","tag-intec-duoball","tag-intec-duoball-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2142,"name":"DBB valve","slug":"dbb-valve","term_group":0,"term_taxonomy_id":2142,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"},{"term_id":3276,"name":"dbb valves","slug":"dbb-valves","term_group":0,"term_taxonomy_id":3276,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2141,"name":"double block and bleed valve","slug":"double-block-and-bleed-valve","term_group":0,"term_taxonomy_id":2141,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":3278,"name":"intec duoball","slug":"intec-duoball","term_group":0,"term_taxonomy_id":3278,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3277,"name":"INTEC Duoball Valve","slug":"intec-duoball-valve","term_group":0,"term_taxonomy_id":3277,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_3a9674-b3\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET INTEC DUOBALL VALVE PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-intec-duoball-valve\">INTEC Duoball Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe Duo ball valve, developed by KLINGER Sch\u00f6neberg, has a double shut-off of the pipeline and makes it possible to increase the safety of a system significantly. The Duo ball valve is available in the same length as a standard valve and provides a compact and economical alternative to several valves.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe Duo Ball Valve (DBV) is designed for applications with extremely high safety requirements. The DBV consists of two ball valves, which are equipped on request with two independent barriers. Therefore, the safety factor could be increased 4 times compared to a standard ball valve. Due to the double isolation and bleed function each ball valve is tight on both the upstream and downstream sides.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Features of INTEC Duoball Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul><!-- wp:list-item -->\r\n \t<li>Compared to standard ball valves, the safety can be increased by a factor of 4.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>The design is based on the integration of two ball valves in one body.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Like all ball valves of the INTEC series, the Duoball valve is available with a floating ball or trunnion mounted ball as well as soft or metal seated execution<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>All ball seat systems naturally fulfill the leakage rate A according to EN 12266 and are absolutely gas-tight.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Due to the double insulation and venting function, every duoball valve is bi-directionally tight.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>What is DBB Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nA double block and bleed valve are like having three valves in one.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nAPI 6D defines a double block and bleed valve as a \"single valve with two seating surfaces that, in the closed position, provides a seal against pressure from both ends of the valve with a means of venting\/bleeding the cavity between the seating surfaces.\"\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThere are a couple of different styles of double block and bleed valves. One style has two independently seating valves inside, with a bleed or drains valve. This configuration is referred to as a double isolation and bleed (DIB). The DIB valve can isolate either side of the valve (bi-directionally) to vent or bleed the cavity and isolate piping.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThis trunnion style ball valve from ZECO provides a double block and bleed in a single valve. This style can isolate piping on both sides of the valve (uni-directionally) to vent\/bleed the valve cavity between the seats.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nUsing a single double block and bleed valve system versus 3 separate valves saves installation time, weight on the piping system, and space. It also cuts down the number of leak paths to the atmosphere, reducing the risk of hazards when transferring liquids dangerous to humans or the environment.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Features and Benefits of DBB Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDouble Block and Bleed valves have been developed to substitute the process of bolting the individual valves together to provide dual insulation.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThis new model provides excellent savings in weight, space, and installation time, particularly for insulation in the instrument or instrument cage. These weight savings will amount to up to 60% and tests have shown that a time savings of 70% on installation is also possible. The biggest benefits must be seen, however, in reducing the leakage pathways into the environment, thus reducing the possibility of possible dangers.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDual isolation is an essential requirement when maintenance is performed downstream of the first isolation valve. Cavity venting is given by either a ball or a globe vent valve such that the compressed pressure between the two isolation valves is vented safely.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThese valves have also grown to incorporate the role of chemical injection and sampling points. In-built control valves are also incorporated into these valves.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":4,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2142,"label":"DBB valve"},{"value":3276,"label":"dbb valves"},{"value":2141,"label":"double block and bleed valve"},{"value":3278,"label":"intec duoball"},{"value":3277,"label":"INTEC Duoball Valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>ZECO DBB Valve - INTEC Duoball valve | Double Block and Bleed Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/climate-targets-api-approved-valve-manufacturer.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ZECO DBB Valve - INTEC Duoball valve | Double Block and Bleed Valve\" \/>\n<meta property=\"og:description\" content=\"What is DBB Valve? There are two entities in the United States that define DBB\u2014API and OSHA. According to API, a DBB ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/climate-targets-api-approved-valve-manufacturer.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-01-20T08:26:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-08T14:11:39+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"4\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html\",\"name\":\"ZECO DBB Valve - INTEC Duoball valve | Double Block and Bleed Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-01-20T08:26:39+00:00\",\"dateModified\":\"2022-08-08T14:11:39+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html\",\"url\":\"https:\/\/zecovalve.com\/climate-targets-api-approved-valve-manufacturer.html\",\"name\":\"ZECO DBB Valve &#8211; INTEC Duoball valve | Double Block and Bleed Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/15586","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=15586"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/15586\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=15586"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=15586"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=15586"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}