{"id":16681,"date":"2022-06-22T15:04:23","date_gmt":"2022-06-22T15:04:23","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16681"},"modified":"2022-06-22T15:04:24","modified_gmt":"2022-06-22T15:04:24","slug":"the-structure-and-principle-of-the-electric-gate-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/the-structure-and-principle-of-the-electric-gate-valve.html","title":{"rendered":"Aufbau und Prinzip des elektrischen Absperrschiebers"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"h-the-structure-of-gate-valves\">Der Aufbau von Schieberventilen<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der Schieber ist ein Schieber mit vertikaler Bewegungsbahn entlang des zentralen Pfads des Schieberverschlusses. Er besteht im Allgemeinen aus dem Schieberk\u00f6rper, dem Ventilsitz, dem Schaft, dem Keil, der Haube und dem Dichtungsring und kann durch Konfiguration von \u00dcbertragungsvorrichtungen in eine Vielzahl von elektrischen und pneumatischen Schiebern umgewandelt werden. Da er in der Rohrleitung nur vollst\u00e4ndig ein- und ausgeschaltet werden kann, kann er niemals als Regler oder Drossel verwendet werden.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-the-principle-of-gate-valves\">Das Prinzip der Schieberventile<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Der Schieberkeil befindet sich zusammen mit der Spindel in linearer Bewegung. Die Drehbewegung, die durch die obere Mutter und die F\u00fchrungsnut, die sich entlang der Trapezgewindespindel der Hubstange drehen, erreicht wird, wird in eine lineare Bewegung umgewandelt, wodurch das Betriebsdrehmoment in den Betriebsschub umgewandelt wird.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-the-switch-off-of-gate-valves\">Das Abschalten von Schiebern<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Die Dichtfl\u00e4che kann sich durch den Mediendruck selbst abdichten, d. h. der Mediendruck dr\u00fcckt die Dichtfl\u00e4che auf die andere Seite des Schiebers, um die Abdichtung zu erreichen. Dies wird auch als Selbstabdichtung bezeichnet. Die meisten Schieberventile sind zwangsdichtend, d. h. der \u00e4u\u00dfere Druck dr\u00fcckt den Keil auf den Sitz, um die Abdichtung sicherzustellen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-the-switch-on-of-gate-valves\">Das Einschalten von Schiebern<\/h2>\n\n\n\n<p class=\"wp-block-paragraph\">Wenn das Tor auf eine H\u00f6he angehoben wird, die 1:1 des Ventildurchmessers entspricht, ist der Fl\u00fcssigkeitskanal vollst\u00e4ndig ge\u00f6ffnet. Es ist jedoch unm\u00f6glich, dies w\u00e4hrend des Betriebs zu \u00fcberwachen. Im tats\u00e4chlichen Gebrauch dient die Spitze des Schafts als Symbol f\u00fcr eine vollst\u00e4ndige \u00d6ffnung, d. h. die feste Position bedeutet, dass es vollst\u00e4ndig ge\u00f6ffnet ist. Um die temperaturbedingte Blockierung zu ber\u00fccksichtigen, wird eine Drehung zur Spitze mit einer anschlie\u00dfenden 1\/2-1-Rundung als vollst\u00e4ndig ge\u00f6ffnete Position angesehen. Daher wird durch die Position des Torkeils (d. h. Hub) bestimmt, ob es sich um eine vollst\u00e4ndige \u00d6ffnung handelt.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Verwandte Tags:<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/\">ZECO-Ventil<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/difference-between-gate-valves-and-ball-valves.html\/\">Schieberventil vs. Kugelhahn<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/difference-between-gate-valve-and-butterfly-valve.html\/\">Unterschied zwischen Absperrschieber und Absperrklappe<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/gate-valve-problems.html\/\">Reparatur von Absperrschiebern<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/advantages-and-disadvantages-of-globe-valves.html\/\">Was ist ein Durchgangsventil?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/produkt\/manual-gate-valve\/\">Hersteller von manuell bet\u00e4tigten Absperrschiebern<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">Was ist ein Absperrschieber?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/tag\/shanghai-pressure-reducing-valve-factory\/\">Shanghai Druckminderventilfabrik<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Die Struktur von Schieberventilen Ein Schieberventil ist ein Schieber mit einer vertikalen Bewegungsspur entlang des zentralen Pfads von \u2026 <a title=\"Aufbau und Prinzip des elektrischen Absperrschiebers\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/the-structure-and-principle-of-the-electric-gate-valve.html\" aria-label=\"Mehr zu Aufbau und Prinzip des elektrischen Schieberventils\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1928],"tags":[2194,3,2402,2401],"class_list":["post-16681","post","type-post","status-publish","format-standard","hentry","category-gate-valve","tag-electric-gate-valve","tag-gate-valve","tag-principle-of-gate-valves","tag-structure-of-gate-valves","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1928,"name":"Gate Valve","slug":"gate-valve","term_group":0,"term_taxonomy_id":1928,"taxonomy":"category","description":"","parent":0,"count":49,"filter":"raw","cat_ID":1928,"category_count":49,"category_description":"","cat_name":"Gate Valve","category_nicename":"gate-valve","category_parent":0}],"tag_info":[{"term_id":2194,"name":"electric gate valve","slug":"electric-gate-valve","term_group":0,"term_taxonomy_id":2194,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":3,"name":"gate valve","slug":"gate-valve","term_group":0,"term_taxonomy_id":3,"taxonomy":"post_tag","description":"","parent":0,"count":41,"filter":"raw"},{"term_id":2402,"name":"principle of gate valves","slug":"principle-of-gate-valves","term_group":0,"term_taxonomy_id":2402,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2401,"name":"structure of gate valves","slug":"structure-of-gate-valves","term_group":0,"term_taxonomy_id":2401,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1928,"label":"Gate Valve"}],"post_tag":[{"value":2194,"label":"electric gate valve"},{"value":3,"label":"gate valve"},{"value":2402,"label":"principle of gate valves"},{"value":2401,"label":"structure of gate valves"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>The Structure and Principle of the Electric Gate Valve - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/the-structure-and-principle-of-the-electric-gate-valve.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"The Structure and Principle of the Electric Gate Valve - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"The Structure of Gate Valves The gate valve refers to the gate with the vertical motion trail along the central path of ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/the-structure-and-principle-of-the-electric-gate-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-22T15:04:23+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-22T15:04:24+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html\",\"name\":\"The Structure and Principle of the Electric Gate Valve - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-22T15:04:23+00:00\",\"dateModified\":\"2022-06-22T15:04:24+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html\",\"url\":\"https:\/\/zecovalve.com\/the-structure-and-principle-of-the-electric-gate-valve.html\",\"name\":\"The Structure and Principle of the Electric Gate Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/16681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=16681"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/16681\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=16681"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=16681"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=16681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}