{"id":17061,"date":"2022-06-26T08:12:29","date_gmt":"2022-06-26T08:12:29","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17061"},"modified":"2022-08-13T11:25:44","modified_gmt":"2022-08-13T11:25:44","slug":"structural-composition-of-constant-pressure-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/structural-composition-of-constant-pressure-valve.html","title":{"rendered":"Konstantdruckventil \u2013 Druckregelventil"},"content":{"rendered":"<p>Konstantdruckregelventile sind f\u00fcr Anwendungen konzipiert, die einen stabilen Ausgangs- oder Eingangsdruck erfordern. Zu diesen Anwendungen geh\u00f6ren Pasteurisierung, Trennung, Abf\u00fcllsysteme, Filter, Filter und W\u00e4rmetauscher.<\/p>\n\n\n\n\n\n<h2 class=\"wp-block-heading\">Was ist ein <strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\"><a href=\"https:\/\/zecovalve.com\/de\/produktkategorie\/water-control-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">Konstantdruckventil<\/a><\/mark><\/strong>?<\/h2>\n\n\n\n<p>Konstantdruckventile regeln den Systemdruck auf der Abflussseite des Ventils, also zum Tank, zum Druckschalter und zu allen Verbrauchsstellen im Haus.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"330\" height=\"300\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/pressure-reducing-valve.jpg\" alt=\"Druckreduzierventil\" class=\"wp-image-16737\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/pressure-reducing-valve.jpg 330w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/pressure-reducing-valve-300x273.jpg 300w\" sizes=\"auto, (max-width: 330px) 100vw, 330px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Wie funktioniert ein Konstantdruckventil?<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Der Zwischendruck Pe zwischen dem Eingangsdruck (Prim\u00e4rdruck) P1 und dem Ausgangsdruck (Sekund\u00e4rdruck) P2 entsteht im Steuerventil und wird zur Oberseite des Hauptventils \u00fcbertragen, um eine entsprechende Hauptventil\u00f6ffnung aufrechtzuerhalten.<\/li><li>Wenn die Verbrauchsmenge auf der Auslassseite abnimmt und der Auslassdruck P2 \u00fcber den eingestellten Druck steigt, \u00f6ffnet sich das Pilotventil A und das Pilotventil B schlie\u00dft sich, um den Zwischendruck Pe anzuheben. Dies f\u00fchrt dazu, dass das Hauptventil eingeschr\u00e4nkt wird und der Auslassdruck auf den eingestellten Druck reduziert wird.<br>Umgekehrt, wenn die Verbrauchsmenge auf der Auslassseite zunimmt und der Auslassdruck P2 unter den eingestellten Druck f\u00e4llt, schlie\u00dft das Pilotventil A und das Pilotventil B \u00f6ffnet sich, um den Zwischendruck Pe zu senken. Dadurch \u00f6ffnet sich das Hauptventil und der Auslassdruck wird auf den eingestellten Druck erh\u00f6ht.<\/li><li>Mit demselben Mechanismus reagiert das Pilotventil auf Schwankungen des Eingangsdrucks, passt dadurch automatisch die \u00d6ffnung des Hauptventils entsprechend an und h\u00e4lt den Ausgangsdruck auf dem eingestellten Wert.<\/li><li>Im vollst\u00e4ndig geschlossenen Zustand ist das Pilotventil B durch den Ausgangsdruck vollst\u00e4ndig geschlossen und gleichzeitig wird der Eingangsdruck effektiv von der Oberseite des Hauptventils aufgenommen. Das Hauptventil ist daher fest geschlossen und die Eingangs- und Ausgangsseiten sind vollst\u00e4ndig abgesperrt.<\/li><li>Der eingestellte Druck kann mit der Schraubenfeder des Pilotventils fein eingestellt werden.<br>Wenn das Hauptventil, das Pilotventil A oder das Pilotventil B durch Fremdmaterial verstopft wird, \u00f6ffnet sich das verstopfte Ventil als Reaktion auf die durch die Verstopfung bedingte Druck\u00e4nderung und entfernt das Fremdmaterial automatisch.<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\">Struktureller Aufbau des Konstantdruckventils<\/h2>\n\n\n\n<p>Im Ventil befindet sich ein Membran- und Spulenkolbensystem. Das System reagiert sofort auf \u00c4nderungen des Produktdrucks und passt seine Position so an, dass der voreingestellte Druck unver\u00e4ndert bleibt. Das Ventil wird \u00fcber ein Druckregelventil f\u00fcr Druckgas und ein Druckmessger\u00e4t an der Produktionslinie betrieben. Das optimierte Hauptk\u00f6rperdesign verleiht CPM-2 die Vorteile von Produkten, zu denen eine extrem hohe Sauberkeit geh\u00f6rt. Da der Einlass 90 Grad vom Boden des Hauptk\u00f6rpers des Ventils entfernt ist, gibt es keine Ansammlung von Restfl\u00fcssigkeit. Ein spezielles Kolbendesign erm\u00f6glicht einen geringeren Fl\u00fcssigkeitsfluss und einen h\u00f6heren CIP-Fluss. Das Konstantdruckregelventil wird haupts\u00e4chlich verwendet, um den konstanten Probenwasserdruck im Wasserdampfprobenahmeger\u00e4t sicherzustellen. Es ist f\u00fcr das strombegrenzende Regelventil der Firma f\u00fcr die manuelle Probenahme geeignet. Es kann einen konstanten Probenwasserdruck und -strom erreichen, die Genauigkeit der Instrumentenmessung verbessern und die St\u00f6rungen durch Probenwasserdruck und Durchflussschwankungen bei der Instrumentenmessung beheben.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-working-process-of-constant-pressure-valves\">Arbeitsweise von Konstantdruckventilen<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>1. Das Ger\u00e4t zur Konstantdruckregelung kann den Ausgangsdruck durch Einstellen des Handrads zwischen 0,05 und 0,5 MPa einstellen. Wenn der Eingangsdruck stark schwankt, wird die \u00d6ffnung des Ventils im Ventil automatisch angepasst, um den Ausgangsdruck stabil zu halten.<\/li><li>2. Das Konstantdruckregelger\u00e4t verf\u00fcgt \u00fcber die Funktion eines \u00dcberdruckschutzes. Wenn der Ausgangsdruck den eingestellten Wert \u00fcberschreitet, schlie\u00dft das Ventil automatisch, um eine Besch\u00e4digung des Instruments zu verhindern.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Vorteile des Konstantdruckventils<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Kann in beiden Flie\u00dfrichtungen (Upstream und Downstream) eingesetzt werden<\/li><li>Pr\u00e4zise Ventilkegelsteuerung durch mehrlagigen Flachmembranaufbau (lange Lebensdauer)<\/li><li>Perfektionierte Reinigungsf\u00e4higkeit keine Totr\u00e4ume, keine Spalten voll ge\u00f6ffnetes Ventil f\u00fcr ausreichenden CIP-Durchsatz<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\">Hervorragende Druckregelung und vollst\u00e4ndige Fl\u00fcssigkeitsabsperrleistung<\/h3>\n\n\n\n<p>Da die \u00d6ffnungs- und Schlie\u00dfventilteile entlang einer einzigen Achse ausgerichtet sind, erm\u00f6glicht das Pilotventil unter allen Bedingungen eine ausgezeichnete Druckregelung.<\/p>\n\n\n\n<p>Der einzigartige Schlie\u00dfmechanismus sorgt f\u00fcr eine vollst\u00e4ndige Wasserabsperrung. Der eingestellte Ausgangsdruck bleibt auch im vollst\u00e4ndig geschlossenen Zustand erhalten, wodurch die Kosten f\u00fcr Rohre auf der Abflussseite des Ventils gesenkt werden k\u00f6nnen.<\/p>\n\n\n\n<p>Das Pilotventil verf\u00fcgt im Gegensatz zu einem Nadelventil \u00fcber keinen winzigen, festen Drosseldurchgang und ist daher verstopfungssicher.<br>Und selbst wenn es zu einer Verstopfung durch Fremdmaterial kommt, sorgt der integrierte Selbstreinigungsmechanismus daf\u00fcr, dass sich der verstopfte Ventilteil automatisch \u00f6ffnet, um das Fremdmaterial zu entfernen.<\/p>\n\n\n\n<p>Aufgrund der einfachen Konstruktion sind aufw\u00e4ndige Justierungen nicht erforderlich. Da das Ventil eine ausgezeichnete Haltbarkeit aufweist und praktisch wartungsfrei ist, werden durch den Einsatz dieses Ventils die Wartungskosten gesenkt.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Verwandte Tags:<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/\">ZECO-Ventil<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/what-is-an-axial-flow-silent-check-valve.html\/\">Was ist ein Axialr\u00fcckschlagventil<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/difference-between-gate-valves-and-ball-valves.html\/\">Schieberventil vs. Kugelhahn<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/introduction-of-epdm-nbr-butterfly-valve-seat-industrial-valve-information-news-zeco-valve.html\/\">NBR-Absperrklappe<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html\/\">Was sind automatische Regelventile?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/the-difference-between-globe-valve-and-ball-valve.html\/\">Durchgangsventil vs. Kugelhahn<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Konstantdruckregelventile sind f\u00fcr Anwendungen konzipiert, die einen stabilen Ausgangs- oder Eingangsdruck erfordern. Zu diesen Anwendungen geh\u00f6ren Pasteurisierung, Trennung, Abf\u00fcllsysteme, Filter usw. <a title=\"Konstantdruckventil \u2013 Druckregelventil\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/structural-composition-of-constant-pressure-valve.html\" aria-label=\"Mehr zu Konstantdruckventil \u2013 Druckregelventil\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":17014,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[2368],"tags":[3571,3570,3569,3567,3568,2543,2542],"class_list":["post-17061","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-control-valve","tag-constant-pressure-control-valve","tag-constant-pressure-expansion-valve","tag-constant-pressure-modulating-valve","tag-constant-pressure-valve","tag-constant-pressure-valves","tag-pressure-control-valve","tag-water-control-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/pressure-reducing-valve-1.jpg",330,300,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":2368,"name":"Control Valve","slug":"control-valve","term_group":0,"term_taxonomy_id":2368,"taxonomy":"category","description":"","parent":0,"count":12,"filter":"raw","cat_ID":2368,"category_count":12,"category_description":"","cat_name":"Control Valve","category_nicename":"control-valve","category_parent":0}],"tag_info":[{"term_id":3571,"name":"constant pressure control valve","slug":"constant-pressure-control-valve","term_group":0,"term_taxonomy_id":3571,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3570,"name":"constant pressure expansion valve","slug":"constant-pressure-expansion-valve","term_group":0,"term_taxonomy_id":3570,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3569,"name":"constant pressure modulating valve","slug":"constant-pressure-modulating-valve","term_group":0,"term_taxonomy_id":3569,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3567,"name":"constant pressure valve","slug":"constant-pressure-valve","term_group":0,"term_taxonomy_id":3567,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3568,"name":"constant pressure valves","slug":"constant-pressure-valves","term_group":0,"term_taxonomy_id":3568,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2543,"name":"Pressure Control Valve","slug":"pressure-control-valve","term_group":0,"term_taxonomy_id":2543,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2542,"name":"Water Control Valve","slug":"water-control-valve","term_group":0,"term_taxonomy_id":2542,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"}],"taxonomy_info":{"category":[{"value":2368,"label":"Control Valve"}],"post_tag":[{"value":3571,"label":"constant pressure control valve"},{"value":3570,"label":"constant pressure expansion valve"},{"value":3569,"label":"constant pressure modulating valve"},{"value":3567,"label":"constant pressure valve"},{"value":3568,"label":"constant pressure valves"},{"value":2543,"label":"Pressure Control Valve"},{"value":2542,"label":"Water Control Valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Constant Pressure Valve - Pressure Control Valve | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/structural-composition-of-constant-pressure-valve.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Constant Pressure Valve - Pressure Control Valve | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Constant pressure control valves are designed for applications requiring stable outlet or inlet pressure. These applications include pasteurization, separation, filling systems, filters, ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/structural-composition-of-constant-pressure-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-26T08:12:29+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-13T11:25:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/pressure-reducing-valve-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"330\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/pressure-reducing-valve-1.jpg\",\"width\":330,\"height\":300,\"caption\":\"Pressure Reducing Valve\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html\",\"name\":\"Constant Pressure Valve - Pressure Control Valve | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html#primaryimage\"},\"datePublished\":\"2022-06-26T08:12:29+00:00\",\"dateModified\":\"2022-08-13T11:25:44+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html\",\"url\":\"https:\/\/zecovalve.com\/structural-composition-of-constant-pressure-valve.html\",\"name\":\"Constant Pressure Valve &#8211; Pressure Control Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17061","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=17061"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17061\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media\/17014"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=17061"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=17061"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=17061"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}