{"id":17245,"date":"2022-06-27T12:27:08","date_gmt":"2022-06-27T12:27:08","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17245"},"modified":"2022-06-27T12:27:09","modified_gmt":"2022-06-27T12:27:09","slug":"classification-of-thermostatic-balancing-valves","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/classification-of-thermostatic-balancing-valves.html","title":{"rendered":"Klassifizierung von thermostatischen Ausgleichsventilen"},"content":{"rendered":"<p>Das Konstanttemperaturventil l\u00f6st die Probleme des Druckungleichgewichts zwischen hei\u00dfem und kaltem Wasser w\u00e4hrend des Badevorgangs sowie Druck-, Temperatur- und Wassertemperatur\u00e4nderungen. Es erm\u00f6glicht eine k\u00fcnstliche Temperatureinstellung f\u00fcr Heizanlagen, um Energie zu sparen.<\/p>\n\n\n\n\n\n<h2 class=\"wp-block-heading\">Prinzip des thermostatischen Strangregulierventils: <\/h2>\n\n\n\n<p>Am Auslass ist ein hochempfindliches Memory-Legierungsmodul angebracht. Die Temperaturerfassung des Memory-Legierungsmoduls \u00e4ndert die Durchflussrate von hei\u00dfem und kaltem Wasser durch Ausdehnung und Kontraktion, um die austretende Wassertemperatur zu erreichen. Durch die Steuerung des Einlassflusses von W\u00e4rmetauscher, Klimaanlage oder anderen W\u00e4rme-, K\u00fchlger\u00e4ten und prim\u00e4ren W\u00e4rme- (K\u00e4lte-)Medien kann die Auslasstemperatur des Ger\u00e4ts gesteuert werden. Wenn sich die Last \u00e4ndert, kann die Durchflussrate durch \u00c4ndern des \u00d6ffnungsgrads des Ventils angepasst werden, um die Auswirkungen von Lastschwankungen zu eliminieren und die Temperatur auf den eingestellten Wert zur\u00fcckzusetzen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-constant-temperature-valves-include-bath-constant-temperature-faucets-and-radiator-constant-temperature-valves\">Zu den Ventilen mit konstanter Temperatur geh\u00f6ren Badewannen-Wasserh\u00e4hne mit konstanter Temperatur und Heizk\u00f6rperventile mit konstanter Temperatur.<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-bath-thermostat-faucet\">Thermostat-Badarmatur<\/h3>\n\n\n\n<p>Als neuer Ventiltyp ersetzt das Konstanttemperaturventil das herk\u00f6mmliche Kalt- und Warmwasserregelventil und l\u00f6st die Probleme von Wassertemperatur und -w\u00e4rme, die aufgrund der schnellen Druck- und Temperatur\u00e4nderungen beim Baden schwer einzustellen sind. Bei der Verwendung muss nur der Schalter ge\u00f6ffnet werden, damit das Wasser mit konstanter Temperatur abflie\u00dfen kann. Dr\u00fccken Sie beim Einstellen der Temperatur den roten Sicherheitsknopf. Passen Sie die Temperatureinstellung langsam gegen den Uhrzeigersinn an, um Unannehmlichkeiten durch einen zu schnellen Temperaturanstieg zu vermeiden.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-radiator-thermostat\">Heizk\u00f6rperthermostat<\/h3>\n\n\n\n<p>Es wird haupts\u00e4chlich zur automatischen Steuerung des W\u00e4rmehaushalts von Warmwasserheizsystemen und -ger\u00e4ten verwendet. L\u00f6st das Problem des thermischen und hydraulischen Ungleichgewichts im Heizsystem, das durch unterschiedliche Rohrl\u00e4ngen zwischen Geb\u00e4uden, unterschiedliche Gr\u00f6\u00dfen der W\u00e4rmeableitungsfl\u00e4che, unterschiedlichen Widerstand durch unterschiedliche Rohrstrukturen, unterschiedliche Druckunterschiede und unterschiedliche W\u00e4rmeableitungsmengen verursacht wird.<\/p>","protected":false},"excerpt":{"rendered":"<p>Das Konstanttemperaturventil l\u00f6st die Probleme des Druckungleichgewichts zwischen hei\u00dfem und kaltem Wasser w\u00e4hrend des Badevorgangs und bei Druck- und Temperatur\u00e4nderungen \u2026 <a title=\"Klassifizierung von thermostatischen Ausgleichsventilen\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/classification-of-thermostatic-balancing-valves.html\" aria-label=\"Mehr zu Klassifizierung von thermostatischen Strangregulierventilen\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[263,211,34],"class_list":["post-17245","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-heat","tag-temperature","tag-water","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":263,"name":"heat","slug":"heat","term_group":0,"term_taxonomy_id":263,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":211,"name":"temperature","slug":"temperature","term_group":0,"term_taxonomy_id":211,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":34,"name":"water","slug":"water","term_group":0,"term_taxonomy_id":34,"taxonomy":"post_tag","description":"","parent":0,"count":19,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":263,"label":"heat"},{"value":211,"label":"temperature"},{"value":34,"label":"water"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Classification of Thermostatic Balancing Valves - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/classification-of-thermostatic-balancing-valves.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Classification of Thermostatic Balancing Valves - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"The constant temperature valve solves the problems of pressure unbalance between hot and cold water during bathing process and pressure change, temperature ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/classification-of-thermostatic-balancing-valves.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T12:27:08+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-27T12:27:09+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"1\u00a0Minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html\",\"name\":\"Classification of Thermostatic Balancing Valves - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-27T12:27:08+00:00\",\"dateModified\":\"2022-06-27T12:27:09+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html\",\"url\":\"https:\/\/zecovalve.com\/classification-of-thermostatic-balancing-valves.html\",\"name\":\"Classification of Thermostatic Balancing Valves\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17245","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=17245"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17245\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=17245"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=17245"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=17245"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}