{"id":17274,"date":"2022-06-27T12:44:51","date_gmt":"2022-06-27T12:44:51","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17274"},"modified":"2022-08-03T15:38:32","modified_gmt":"2022-08-03T15:38:32","slug":"backwater-temperature-regulation-method-for-hot-water-heating-syste","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html","title":{"rendered":"R\u00fcckstautemperatur-Regelungsverfahren f\u00fcr Warmwasserheizsysteme"},"content":{"rendered":"<p>Als eine der prim\u00e4ren Regelungsmethoden f\u00fcr Warmwasserheizsysteme eignet sich die R\u00fccklauftemperaturregelung f\u00fcr Warmwasserheizsysteme f\u00fcr Rohrleitungsnetze ohne Regelventile. Wenn am Benutzereingang des Rohrleitungsnetzes kein Ausgleichsventil installiert ist oder wenn die Druckmesser an beiden Enden des normalen Regelventils am Eingang nicht vollst\u00e4ndig sind oder wenn der Eingang des Rohrleitungsnetzes nur \u00fcber das normale Ventil verf\u00fcgt, kann die R\u00fccklauftemperaturregelung zur Anpassung verwendet werden.<\/p>\n\n\n\n\n\n<p>Chinesischer Name: R\u00fcckstautemperatur-Regelungsverfahren f\u00fcr Warmwasserheizsysteme<\/p>\n\n\n\n<p>Ausl\u00e4ndischer Name: Die R\u00fccklauftemperaturregelung eines Warmwasserheizsystems<\/p>\n\n\n\n<p>Zweck: Den Betriebsdurchfluss von W\u00e4rmeverbrauchern auf die ideale Durchflussmenge einstellen.<\/p>\n\n\n\n<p>Fachgebiet: Heizungsregelung<\/p>\n\n\n\n<p>Besonderheit: Geeignet f\u00fcr Rohrleitungsnetze ohne Regelventil<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-regulation-theory\">Regulierungstheorie<\/h2>\n\n\n\n<p>Wenn das Heizsystem stabil l\u00e4uft und die Verluste im Rohrleitungsnetz nicht ber\u00fccksichtigt werden, sollte die vom Heizmedium an die W\u00e4rmeableitungsger\u00e4te im Haus gelieferte W\u00e4rme der W\u00e4rmeableitung der W\u00e4rmeableitungsger\u00e4te und der W\u00e4rmelast des Heizungsnutzers entsprechen. Die vom Rohrleitungsnetz an die W\u00e4rmeableitungsger\u00e4te im Haus gelieferte W\u00e4rme ist gleich dem Produkt aus Durchflussrate, Temperaturdifferenz zwischen Vor- und R\u00fccklaufwasser und spezifischer W\u00e4rme des Warmwassers. Wenn die tats\u00e4chliche Durchflussrate gr\u00f6\u00dfer ist als die Auslegungsdurchflussrate, verringert sich die Temperaturdifferenz zwischen Vor- und R\u00fccklaufwasser und die R\u00fccklaufwassertemperatur ist h\u00f6her als der angegebene Wert. Wenn die tats\u00e4chliche Durchflussrate geringer ist als die Auslegungsdurchflussrate, erh\u00f6ht sich die Temperaturdifferenz zwischen Vor- und R\u00fccklaufwasser und die R\u00fccklaufwassertemperatur ist niedriger als der stabile Wert.<\/p>\n\n\n\n<p>Solange also die R\u00fccklaufwassertemperatur jedes Verbrauchers gleich ist (wenn die Wasserversorgungstemperatur gleich ist) oder der Temperaturunterschied zwischen dem Vorlauf- und dem R\u00fccklaufwasser gleich ist (die Isolierwirkung der Rohrleitung ist schlecht, die Wasserversorgungstemperatur ist leicht unterschiedlich), k\u00f6nnen die W\u00e4rmeverbraucher die W\u00e4rme erhalten, die der W\u00e4rmelast entspricht, und das Ziel einer gleichm\u00e4\u00dfigen Regelung erreichen.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Diese Methode ist die einfachste, primitivste und zeitaufw\u00e4ndigste. <\/h2>\n\n\n\n<p>Es kann in jedem Heizsystem verwendet werden. Es erfordert keine Ventile, Druckmesser und Thermometer. Es wird lediglich ein Infrarotthermometer oder ein digitales Oberfl\u00e4chenthermometer ben\u00f6tigt.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">(1) Bestimmung der Regeltemperatur<\/h3>\n\n\n\n<p>Wenn die W\u00e4rmezufuhr der W\u00e4rmequelle gr\u00f6\u00dfer oder gleich der W\u00e4rmelast des Benutzers ist und der Durchfluss der Umw\u00e4lzpumpe h\u00f6her als der Auslegungsdurchfluss ist, sollte die R\u00fccklaufwassertemperatur des Benutzers unter Ber\u00fccksichtigung des Energiesparbetriebs der Umw\u00e4lzpumpe auf die R\u00fccklaufwassertemperatur entsprechend der Temperaturregelkurve angepasst werden. Wenn die W\u00e4rmezufuhr der W\u00e4rmequelle gr\u00f6\u00dfer oder gleich der W\u00e4rmelast des Benutzers ist und der Durchfluss der Umw\u00e4lzpumpe geringer als der Auslegungsdurchfluss ist, sollte die Durchschnittstemperatur von Vor- und R\u00fccklaufwasser auf die Durchschnittstemperatur von Vor- und R\u00fccklaufwasser entsprechend der Temperaturregelkurve angepasst werden. Wenn die W\u00e4rmezufuhr der W\u00e4rmequelle geringer als die W\u00e4rmelast des Benutzers ist, sollte die R\u00fccklaufwassertemperatur des Benutzers auf einen Wert angepasst werden, der etwas niedriger als die gesamte R\u00fccklaufwassertemperatur ist.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">(2) Regulierungsprozess<\/h3>\n\n\n\n<p>Aufgrund der gro\u00dfen thermischen Tr\u00e4gheit des Heizsystems \u00e4ndert sich die Temperatur nach dem Band deutlich. Nach dem Einstellen der Durchflussrate des Systems kann die Temperatur des Systems die \u00c4nderung der Durchflussrate nicht rechtzeitig widerspiegeln, sodass die Einstellung der Ventil\u00f6ffnung ein gewisses Ma\u00df an Erfahrung erfordert. Die Messtemperatur sollte von allen Benutzern nach einer gewissen Zeit angepasst werden. Die Intervallzeit h\u00e4ngt von der Gr\u00f6\u00dfe des Systems ab. Wenn die Gesamtr\u00fcckstautemperatur bei einem bestimmten Wert stabil ist, kann die n\u00e4chste Anpassungsrunde durchgef\u00fchrt werden.<\/p>\n\n\n\n<p>Zun\u00e4chst wird die R\u00fcckstautemperatur jedes Benutzers aufgezeichnet und mit der Gesamtr\u00fcckstautemperatur verglichen. Je h\u00f6her die Temperatur, desto kleiner schlie\u00dft das Ventil. Bei gleichem R\u00fcckstautemperaturunterschied zwischen den Benutzern gilt: Je gr\u00f6\u00dfer der Rohrdurchmesser, desto st\u00e4rker ist es geschlossen. In der ersten Anpassungsrunde sollte das proximale Endbenutzerventil \u00fcberm\u00e4\u00dfig schlie\u00dfen. Notieren Sie die Anzahl der Ventilschlie\u00dfzyklen f\u00fcr jeden Benutzer.<\/p>\n\n\n\n<p>Nachdem die erste Anpassungsrunde abgeschlossen ist, wird die R\u00fccklaufwassertemperatur des Benutzers aufgezeichnet, nachdem die Gesamtr\u00fccklaufwassertemperatur stabil und unver\u00e4ndert ist, und mit der Temperatur vor der Anpassung verglichen. Anschlie\u00dfend wird sie mit der Gesamtr\u00fccklaufwassertemperatur f\u00fcr die zweite Anpassungsrunde verglichen. Das Intervall zwischen der ersten und zweiten Runde sollte mehr als doppelt so lang sein wie die Zeit, die der am weitesten entfernte Benutzer ben\u00f6tigt, um nach der ersten Anpassung Wasser zur W\u00e4rmequelle zur\u00fcckzugeben. Sch\u00e4tzungen werden anhand der Durchflussrate des Netzwerks und der l\u00e4ngsten Benutzerrohrl\u00e4nge usw. vorgenommen.<\/p>","protected":false},"excerpt":{"rendered":"<p>Als eine der prim\u00e4ren Regelungsmethoden eines Warmwasserheizungssystems ist die R\u00fccklauftemperaturregelungsmethode der Warmwasserheizung \u2026 <a title=\"R\u00fcckstautemperatur-Regelungsverfahren f\u00fcr Warmwasserheizsysteme\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\" aria-label=\"Mehr zu R\u00fcckstautemperatur-Regelungsverfahren f\u00fcr Warmwasser-Heizungssysteme\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[290,211,34],"class_list":["post-17274","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-return","tag-temperature","tag-water","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":290,"name":"return","slug":"return","term_group":0,"term_taxonomy_id":290,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":211,"name":"temperature","slug":"temperature","term_group":0,"term_taxonomy_id":211,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":34,"name":"water","slug":"water","term_group":0,"term_taxonomy_id":34,"taxonomy":"post_tag","description":"","parent":0,"count":19,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":290,"label":"return"},{"value":211,"label":"temperature"},{"value":34,"label":"water"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Backwater Temperature Regulation Method for Hot Water Heating Syste - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Backwater Temperature Regulation Method for Hot Water Heating Syste - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"As one of the primary regulation methods of hot water heating system, the return water temperature regulation method of hot water heating ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T12:44:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-03T15:38:32+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"3\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\",\"name\":\"Backwater Temperature Regulation Method for Hot Water Heating Syste - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-27T12:44:51+00:00\",\"dateModified\":\"2022-08-03T15:38:32+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\",\"url\":\"https:\/\/zecovalve.com\/backwater-temperature-regulation-method-for-hot-water-heating-syste.html\",\"name\":\"Backwater Temperature Regulation Method for Hot Water Heating Syste\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17274","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=17274"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17274\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=17274"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=17274"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=17274"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}