{"id":17498,"date":"2022-06-27T15:43:00","date_gmt":"2022-06-27T15:43:00","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17498"},"modified":"2022-09-21T00:56:31","modified_gmt":"2022-09-21T00:56:31","slug":"working-principle-of-constant-pressure-control-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/working-principle-of-constant-pressure-control-valve.html","title":{"rendered":"Funktionsprinzip des Konstantdruckregelventils"},"content":{"rendered":"<h2 class=\"wp-block-heading\"><strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\"><a href=\"https:\/\/zecovalve.com\/de\/produktkategorie\/water-control-valve\/\">Konstantdruckventil<\/a><\/mark><\/strong><\/h2>\n\n\n\n<p>Da die \u00d6ffnungs- und Schlie\u00dfventilteile entlang einer einzigen Achse ausgerichtet sind, erm\u00f6glicht das Pilotventil unter allen Bedingungen eine ausgezeichnete Druckregelung.<\/p>\n\n\n\n<p>Der einzigartige Schlie\u00dfmechanismus sorgt f\u00fcr eine vollst\u00e4ndige Wasserabsperrung. Der eingestellte Ausgangsdruck bleibt auch im vollst\u00e4ndig geschlossenen Zustand erhalten, wodurch die Kosten f\u00fcr Rohre auf der Abflussseite des Ventils gesenkt werden k\u00f6nnen.<\/p>\n\n\n\n<p>Das Pilotventil verf\u00fcgt im Gegensatz zu einem Nadelventil \u00fcber keinen winzigen, festen Drosseldurchgang und ist daher verstopfungssicher.<br>Und selbst wenn es zu einer Verstopfung durch Fremdmaterial kommt, sorgt der integrierte Selbstreinigungsmechanismus daf\u00fcr, dass sich der verstopfte Ventilteil automatisch \u00f6ffnet, um das Fremdmaterial zu entfernen.<\/p>\n\n\n\n<p>Aufgrund der einfachen Konstruktion sind aufw\u00e4ndige Justierungen nicht erforderlich. Da das Ventil eine ausgezeichnete Haltbarkeit aufweist und praktisch wartungsfrei ist, werden durch den Einsatz dieses Ventils die Wartungskosten gesenkt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Spezifikationen des Konstantdruckregelventils<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Eingangsdruck (Prim\u00e4rdruck)<br>Max. 1 MPa (f\u00fcr JIS 10K-Standard)<\/li><li>Ausgangsdruck (Sekund\u00e4rdruck)<br>50 kPa oder mehr<\/li><li>Pilotventiltyp<br>2. Druck ist max. 0,7 MPa: PLV (Membrantyp)<br>2. Druck ist h\u00f6her als 0,7 MPa: PLV-H (Kolbentyp)<\/li><li>Einstellbereich des Drucks festlegen<br>+\/- 70 kPa<\/li><li>Betriebsdifferenzdruck<br>50 kPa oder mehr<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Hersteller von Konstantdruckregelventilen<\/h2>\n\n\n\n<p>Pumpensteuerventil mit konstantem Druck \u201eCity Like Pressure\u201c, das schnelle Pumpenzyklen reduziert und einen voreingestellten Betriebsdruck aufrechterh\u00e4lt. Es bietet bew\u00e4hrten Pumpenzyklusschutz f\u00fcr Wasserbrunnensysteme, Bew\u00e4sserungs- und Druckerh\u00f6hungssysteme und wurde entwickelt, um schnelle Pumpenzyklen zu stoppen, Strom zu sparen und Wasserschl\u00e4ge zu vermeiden, w\u00e4hrend es unabh\u00e4ngig vom Wasserdurchfluss einen konstanten Druck bietet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Komponenten von Konstantdruckregelventilen<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Einstellung des konstanten Drucks: In der Mitte des Teils befindet sich ein Loch. Der hohe Druck in der Flasche wird durch das Loch in die Kammer mit konstantem Druck eingespritzt. Der konstante Druck kann durch Einstellen des Abstands zwischen dem Teil und der Dichtung mit konstantem Druck gesteuert werden.<\/li><li>Konstantdruckdichtung: Die Funktion besteht darin, das mittlere Loch der Konstantdruck-Einstellschraube zu blockieren. Der hohe Druck in der Flasche str\u00f6mt durch das mittlere Loch der Konstantdruck-Einstellschraube, flie\u00dft durch den Spalt zwischen dem Ventilk\u00f6rper und dem Konstantdruckventilkern und gelangt in das mittlere Loch des Kerns. Schlie\u00dflich erreicht er die Luftkammer. Wenn der Druck allm\u00e4hlich ansteigt, wird der Konstantdruckventilkern in Richtung der Konstantdruck-Einstellschraube gedr\u00fcckt. Wenn der Druck einen bestimmten Wert erreicht, wird die mit dem Ventilkern verbundene Konstantdruckdichtung fest blockiert. Halten Sie die Konstantdruck-Einstellschraube fest, um das Ziel des konstanten Drucks zu erreichen.<\/li><li>Einwegventilkugel: Diese Kugel dient beim Entl\u00fcften als Stopper und verhindert, dass hoher Druck in der Flasche in die Gaskammer gelangt. \u00d6ffnen Sie sie beim F\u00fcllen, um externes Hochdruckgas in den Zylinder zu lassen<\/li><li>Abluftloch: Dieses Loch dient dazu, den \u201eatmenden\u201c Gasstrom zu unterbinden, der durch die schnelle Bewegung des Federteils des Konstantdruckventilkerns verursacht wird.<\/li><li>Begrenzungskarte: um zu verhindern, dass der Konstantdruckventilkern in die Luftkammer f\u00e4llt.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-working-principle-of-constant-pressure-control-valve\">Funktionsprinzip des Konstantdruckregelventils<\/h2>\n\n\n\n<p>Die obere Auslassstange wird in die Kammer gedr\u00fcckt \u2013 obere Ventilstange \u00f6ffnet sich \u2013 Dichtungsdichtung verl\u00e4sst den Ventilk\u00f6rper \u2013 Entl\u00fcftungsluft wird abgelassen \u2013 Kammerdruck sinkt \u2013 Kern f\u00fcr konstanten Druck bewegt sich unter Federwirkung in die Kammer \u2013 Dichtungsdichtung f\u00fcr konstanten Druck verl\u00e4sst den Regelbolzen f\u00fcr konstanten Druck \u2013 hoher Druck im Zylinder tritt in die Kammer ein \u2013 obere Ventilstange \u00f6ffnet sich \u2013 Schlie\u00dfung der Kammer \u2013 Druck steigt \u2013 Ventilkern f\u00fcr konstanten Druck dr\u00fcckt allm\u00e4hlich bis zum Regelbolzen f\u00fcr konstanten Druck \u2013 Druck erreicht den Wert von * Dichtung f\u00fcr konstanten Druck blockiert das mittlere Loch des Einstellbolzens f\u00fcr konstanten Druck \u2026 Vollst\u00e4ndiger konstanter Druck.<\/p>","protected":false},"excerpt":{"rendered":"<p>Konstantdruckventil Da sowohl die \u00d6ffnungs- als auch die Schlie\u00dfventilteile entlang einer einzigen Achse ausgerichtet sind, bietet das Pilotventil eine ausgezeichnete Druckleistung \u2026 <a title=\"Funktionsprinzip des Konstantdruckregelventils\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/working-principle-of-constant-pressure-control-valve.html\" aria-label=\"Mehr zu Funktionsprinzip eines Konstantdruckregelventils\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":16945,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[3571,3567,3568,3915],"class_list":["post-17498","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-constant-pressure-control-valve","tag-constant-pressure-valve","tag-constant-pressure-valves","tag-pressure-control-valve-working-principles","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/water-control-valve.jpg",600,400,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":3571,"name":"constant pressure control valve","slug":"constant-pressure-control-valve","term_group":0,"term_taxonomy_id":3571,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3567,"name":"constant pressure valve","slug":"constant-pressure-valve","term_group":0,"term_taxonomy_id":3567,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3568,"name":"constant pressure valves","slug":"constant-pressure-valves","term_group":0,"term_taxonomy_id":3568,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3915,"name":"pressure control valve working principles","slug":"pressure-control-valve-working-principles","term_group":0,"term_taxonomy_id":3915,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":3571,"label":"constant pressure control valve"},{"value":3567,"label":"constant pressure valve"},{"value":3568,"label":"constant pressure valves"},{"value":3915,"label":"pressure control valve working principles"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Working Principle of Constant Pressure Control Valve | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/working-principle-of-constant-pressure-control-valve.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Working Principle of Constant Pressure Control Valve | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Constant Pressure Valve With both opening and closing valve parts being aligned along a single axis, the pilot valve performs excellent pressure ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/working-principle-of-constant-pressure-control-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T15:43:00+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-21T00:56:31+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/water-control-valve.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"400\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"2\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/water-control-valve.jpg\",\"width\":600,\"height\":400},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html\",\"name\":\"Working Principle of Constant Pressure Control Valve | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html#primaryimage\"},\"datePublished\":\"2022-06-27T15:43:00+00:00\",\"dateModified\":\"2022-09-21T00:56:31+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html\",\"url\":\"https:\/\/zecovalve.com\/working-principle-of-constant-pressure-control-valve.html\",\"name\":\"Working Principle of Constant Pressure Control Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17498","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=17498"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/17498\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media\/16945"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=17498"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=17498"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=17498"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}