{"id":2165,"date":"2021-12-28T10:05:18","date_gmt":"2021-12-28T10:05:18","guid":{"rendered":"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html"},"modified":"2022-11-01T02:58:23","modified_gmt":"2022-11-01T02:58:23","slug":"natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/de\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html","title":{"rendered":"Naturzugk\u00fchlturm und mechanischer Zugk\u00fchlturm"},"content":{"rendered":"<p>In vielen Industrieanlagen m\u00fcssen verschiedene Ger\u00e4te sowie viele in Prozesssystemen verwendete Fl\u00fcssigkeiten gek\u00fchlt werden. Diese K\u00fchlung erfolgt meist mit Wasser. Da K\u00fchlwasser jedoch W\u00e4rme absorbiert, verliert es seine K\u00fchlwirkung. Das Wasser muss k\u00fchl gehalten werden.<\/p>\n\n\n\n<p>Das Ablassen von hei\u00dfem Wasser in Teiche oder Becken kann sch\u00e4dlich f\u00fcr die Umwelt sein. Au\u00dferdem ist es kostspielig, das abgelassene Wasser zu ersetzen. Die effizientere Methode besteht darin, das hei\u00dfe Wasser abzuk\u00fchlen und wiederzuverwenden.<\/p>\n\n\n\n<p>Das hierf\u00fcr am h\u00e4ufigsten verwendete Ger\u00e4t ist der K\u00fchlturm. K\u00fchlt\u00fcrme sind Teil eines K\u00fchlwassersystems in einer gewerblichen oder industriellen Anlage.<\/p>\n\n\n\n\n\n<p>Im W\u00e4rmetauscher wird die W\u00e4rme einer Prozessfl\u00fcssigkeit auf das K\u00fchlwasser \u00fcbertragen. Nachdem das Wasser die W\u00e4rme aus der Prozessfl\u00fcssigkeit aufgenommen hat, flie\u00dft es vom W\u00e4rmetauscher zur Spitze des K\u00fchlturms. Das Wasser f\u00e4llt dann durch den Turm und wird der Luft ausgesetzt, die es wiederum abk\u00fchlt. Das abgek\u00fchlte Wasser sammelt sich am Boden des Turms und wird zur Wiederverwendung durch das System zur\u00fcckgepumpt. K\u00fchlt\u00fcrme k\u00fchlen Wasser, indem sie es der Luft aussetzen, wodurch ein Teil des Wassers verdunstet. Verdunstung ist ein Prozess, bei dem die im Wasser enthaltene W\u00e4rme dazu f\u00fchrt, dass ein Teil des Wassers zu Dampf wird. Wenn das Wasser zu Dampf wird, wird die W\u00e4rme entfernt, was zu gek\u00fchltem Wasser f\u00fchrt. In einem K\u00fchlturm wird die im Wasser enthaltene W\u00e4rme im Dampf aus dem Turm entfernt, wenn das Wasser verdunstet.<\/p>\n\n\n\n<p>W\u00e4rmeleitung und Konvektion spielen in einem K\u00fchlturm eine wichtige Rolle. Im Turm kommt das Wasser in direkten Kontakt mit der Luft. Dabei wird ein Teil der W\u00e4rme im Wasser durch W\u00e4rmeleitung und Konvektion direkt an die Luft abgegeben.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Welche Arten von K\u00fchlturmventilen gibt es?<\/h2>\n\n\n\n<p>Alle K\u00fchlt\u00fcrme funktionieren grunds\u00e4tzlich nach dem gleichen Prinzip. Allerdings kann man sie konstruktionsm\u00e4\u00dfig in zwei Typen unterteilen: Naturzugt\u00fcrme und Saugzugt\u00fcrme. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-what-is-a-natural-draft-cooling-tower\">Was ist ein Naturzugk\u00fchlturm?<\/h2>\n\n\n\n<p>Ein Naturzugk\u00fchlturm ist ein offener W\u00e4rmetauscher mit direktem Kontakt, bei dem hei\u00dfes Wasser aus dem System oder Kondensator durch direkten Kontakt mit Frischluft gek\u00fchlt wird. K\u00fchlt\u00fcrme nutzen das Prinzip der Wasserverdunstung gegen den Luftstrom. Hei\u00dfes Wasser wird aus den D\u00fcsen gespr\u00fcht, um die W\u00e4rme\u00fcbertragungsfl\u00e4che zu vergr\u00f6\u00dfern. Temperatur und Luftfeuchtigkeit steigen nach der W\u00e4rme\u00fcbertragung durch direkten Kontakt zwischen hei\u00dfem Wasser und Frischluft. Die warme und feuchte Luft, die weniger dicht ist, gelangt nach oben in den Turm, und kaltes Wasser sammelt sich unten im Turm. Aufgrund des Dichteunterschieds zwischen der hei\u00dfen Luft im Schornstein und der atmosph\u00e4rischen Luft au\u00dferhalb des K\u00fchlturms wird Frischluft vom Boden des K\u00fchlturms zugef\u00fchrt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prinzip des Naturzugk\u00fchlturms<\/h2>\n\n\n\n<p>Bei Naturzugk\u00fchlturmsystemen wird der Luftstrom durch den Kamineffekt der eigentlichen K\u00fchlturmstruktur erreicht, der den nat\u00fcrlichen Druckunterschied ausnutzt. Warme und feuchte Luft hat eine geringere Dichte, wodurch sie aus dem K\u00fchlturm in die Atmosph\u00e4re aufsteigt und dichtere Frischluft ansaugt. Der Unterschied zwischen der warmen Luft im Turm und der k\u00fchleren Luft drau\u00dfen erzeugt den perfekten Luftstrom. Damit ein ausreichender Luftstrom entsteht, wird die H\u00f6he des K\u00fchlturms mithilfe einer bestimmten mathematischen Formel berechnet, um sicherzustellen, dass sie fast so gro\u00df ist wie der Dichteunterschied. Das bedeutet, dass K\u00fchlt\u00fcrme mit diesem System in der Regel gro\u00df sind: etwa 200 Meter hoch und 150 Meter breit. In den T\u00fcrmen flie\u00dft auch eine betr\u00e4chtliche Menge Wasser. Die H\u00fclle selbst besteht normalerweise aus Beton und hat eine hyperbolische Form. Der Naturzugk\u00fchlturm ist die bevorzugte Wahl f\u00fcr k\u00fchles und feuchtes Klima und f\u00fcr schwere Winterlasten.<\/p>\n\n\n\n<p>Hei\u00dfes Wasser, das im Naturzugk\u00fchlturm gek\u00fchlt werden muss, wird \u00fcber den Hei\u00dfwassereinlass eingepumpt. Der Einlass ist mit D\u00fcsen verbunden, die das Wasser \u00fcber das F\u00fcllmaterial spr\u00fchen, wodurch eine gro\u00dfe Oberfl\u00e4che f\u00fcr die W\u00e4rme\u00fcbertragung entsteht. Am Boden des Turms ist die Struktur offen, um Frischluft anzusaugen, die dann nach oben str\u00f6mt und eine direkte W\u00e4rme\u00fcbertragung zwischen dem warmen Wasser und der Luft erm\u00f6glicht. Das hei\u00dfe Wasser gibt W\u00e4rme ab, nachdem es in direkten Kontakt mit der Frischluft gekommen ist, und ein Teil des hei\u00dfen Wassers verdunstet. Kaltes Wasser wird am Boden des Turms gesammelt.<\/p>\n\n\n\n<p>Die warme und feuchte Luft wird von der Spitze des Turms in die Atmosph\u00e4re abgeleitet.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vorteile von Naturzugk\u00fchlt\u00fcrmen<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Da kein elektrischer L\u00fcfter eingebaut ist, wird Energie gespart.<\/li><li>Keine Korrosionsprobleme<\/li><li>Der Wartungsaufwand ist gering<\/li><li>Keine Luftr\u00fcckf\u00fchrung durch hohen Kaminauslass<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Nachteile Naturzugk\u00fchlt\u00fcrme<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Riesiger Wasserdurchfluss erforderlich.<\/li><li>Diese ben\u00f6tigen eine gro\u00dfe Fl\u00e4che.<\/li><li>Seine Leistung h\u00e4ngt von Windgeschwindigkeit und -richtung ab.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Was ist ein K\u00fchlturm mit mechanischem Zug?<\/h2>\n\n\n\n<p>Saugzugk\u00fchlt\u00fcrme sind eine Art mechanischer Zugturm mit einem oder mehreren Ventilatoren. Diese Ventilatoren befinden sich oben auf dem Turm und ziehen Luft nach oben gegen den nach unten flie\u00dfenden Wasserstrom. Das Wasser wird um die Holzf\u00fcllung oder -verkleidung herumgeleitet. Bei diesen Modellen befindet sich das k\u00fchlste Wasser unten und kommt dort mit der trockensten Luft in Kontakt, da der Luftstrom dem Wasserstrom entgegengerichtet ist.<\/p>\n\n\n\n<p>Da das w\u00e4rmste Wasser in der N\u00e4he der Turmspitze mit feuchter Luft in Kontakt kommt, ergibt sich eine unglaublich effiziente W\u00e4rme\u00fcbertragung. Induzierte T\u00fcrme sind entweder rund oder quadratisch und verteilen das Wasser \u00fcber ein Sprinkler- oder statisches Abzweigsystem. Einstr\u00f6mendes Wasser wird mit einem Spr\u00fchverteilerkopf in den gesamten Turm eingespritzt. Der Spr\u00fchstrahl wird nach unten gerichtet, um den Kontakt von Wasser und Luft zu maximieren. Dieser Prozess wird durch die K\u00fchlwasserf\u00fcllung maximiert, die aus Holz, Metall, PVC oder anderen Materialien besteht. Im Allgemeinen bieten Modelle mit induziertem Luftzug die effektivste L\u00f6sung f\u00fcr die K\u00fchlanforderungen jeder Branche.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Prinzip des K\u00fchlturms mit mechanischem Zug<\/h2>\n\n\n\n<p>Das flie\u00dfende Konditionierungswasser wird mit einem Spr\u00fchdispersionskopf in einem Saugzugk\u00fchlturm durch die gesamte K\u00fchlstation gespr\u00fcht. Das Wasser flie\u00dft vertikal durch Leitbleche, um die Zeit, in der das Wasser in Kontakt mit der Luft ist, zu maximieren.<\/p>\n\n\n\n<p>Die K\u00fchlwasserf\u00fcllung, bestehend aus PVC, Holz, Metall oder einem anderen Element, maximiert die W\u00e4rme\u00fcbertragungskontaktfl\u00e4che.<\/p>\n\n\n\n<p>Durch richtig konstruierte \u201eK\u00f6rperplatten\u201c gelangt Luft in das Innere des K\u00fchlturms. Gro\u00dfe Ventilatoren ziehen Luft durch den abgeschirmten Bereich und k\u00fchlen das Wasser ab. Um zu verhindern, dass Wassertropfen im abstr\u00f6menden Luftstrom h\u00e4ngen bleiben, werden spezielle Vorrichtungen, sogenannte Tropfenabscheider, eingesetzt.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Vorteile eines K\u00fchlturms mit mechanischem Zug<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Geringe Aufnahmekapazit\u00e4t.<\/li><li>H\u00f6herer Ger\u00e4uschpegel als bei Druckbel\u00fcftung.<\/li><li>Antrieb durch feuchten Luftstrom.<\/li><li>Ben\u00f6tigt wenig Platz f\u00fcr die Installation.<\/li><\/ul>\n\n\n\n<p>In einem mechanischen Zugturm wird der Luftstrom durch einen oder mehrere Ventilatoren erzeugt. Ein Saugzugk\u00fchlturm verwendet die Ventilatoren oben auf dem Turm, um einen Bereich mit niedrigem Druck zu erzeugen. Dadurch str\u00f6mt die Luft von den Seiten des Turms nach oben. In diesem Fall tritt Wasser durch Einlassrohre ein und wird in Rinnen verteilt. D\u00fcsen leiten das Wasser aus den Rinnen auf die F\u00fcllk\u00f6rper im Inneren des Turms. Die F\u00fcllk\u00f6rper bremsen das Wasser, w\u00e4hrend es durch den Turm f\u00e4llt, und zerlegen es au\u00dferdem in kleine Tr\u00f6pfchen. Beide dieser Aktionen erm\u00f6glichen eine bessere W\u00e4rme\u00fcbertragung. W\u00e4hrend das Wasser durch den Turm \u00fcber die F\u00fcllk\u00f6rperschichten nach unten flie\u00dft, saugt ein Ventilator die Luft durch eine Reihe von Lamellen um die F\u00fcllk\u00f6rper herum und dann durch einen Tropfenabscheider ein. Der Tropfenabscheider f\u00e4ngt Wassertr\u00f6pfchen auf, die mit der Luft, die den Turm verl\u00e4sst, mitgerissen werden k\u00f6nnten. Das Wasser ist abgek\u00fchlt, wenn es das Auffangbecken erreicht. Das kalte Wasser wird dann durch die Auslassleitung aus dem Turm gezogen und zur Wiederverwendung in die Anlagenausr\u00fcstung zur\u00fcckgef\u00fchrt.<\/p>\n\n\n\n<p>Ein anderer Typ eines mechanischen Zugturms ist der Druckzugk\u00fchlturm. Der Hauptunterschied zwischen einem Saugzug- und einem Druckzugturm besteht darin, dass ein Druckzugturm keinen Bereich mit niedrigem Druck erzeugt, der Luft durch den Turm zieht. Stattdessen dr\u00fccken oder pumpen Ventilatoren die Luft durch den Turm nach oben. Druckzugt\u00fcrme haben keine Lamellen an den Seiten, sondern Ventilatoren mit Sieben, die den Luftstrom in den Turm leiten. W\u00e4hrend das K\u00fchlwasser von der Turmspitze herabf\u00e4llt, dr\u00fccken die Ventilatoren die Luft durch den Turm nach oben und der W\u00e4rme\u00fcbertragungsprozess findet statt.<\/p>\n\n\n\n<p>Einige Komponenten sind bei den meisten T\u00fcrmen gleich. Viele T\u00fcrme sind beispielsweise in Zellen unterteilt. Jede Zelle enth\u00e4lt alle Komponenten eines einzelnen Turms, au\u00dfer dass sie sich ein gemeinsames Auffangbecken teilen. Um die K\u00fchlung besser kontrollieren zu k\u00f6nnen, kann jede Zelle eines Turms unabh\u00e4ngig in Betrieb genommen oder au\u00dfer Betrieb genommen werden. Andere gemeinsame Komponenten sind Abschl\u00e4mm- und Erg\u00e4nzungsleitungen. Wenn das Wasser im Turm verdunstet, steigt die Konzentration der Verunreinigungen an und kann Probleme verursachen. Um die Konzentration der Verunreinigungen zu kontrollieren, wird regelm\u00e4\u00dfig Wasser aus dem Auffangbecken durch die Abschl\u00e4mmleitung abgelassen. Dieses Wasser wird dann durch die Erg\u00e4nzungsleitung durch sauberes Wasser ersetzt. Der Durchfluss durch die Erg\u00e4nzungsleitung wird durch ein Steuerventil kontrolliert, das normalerweise einen Schwimmer hat, der den Pegel im Auffangbecken misst. Wenn sich der Pegel \u00e4ndert, \u00e4ndert der Schwimmer seine Position und sendet ein Signal an das Steuerventil, das den Wasserdurchfluss im System reguliert.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Verwandte Tags:<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/\">ZECO-Ventil<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/gate-valve-problems.html\/\">Reparatur von Absperrschiebern<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/advantages-and-disadvantages-of-globe-valves.html\/\">Was ist ein Durchgangsventil?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/the-function-of-globe-valve-in-pipeline-system.html\/\">Was sind Absperrventile?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/produkt\/manual-gate-valve\/\">Hersteller von manuell bet\u00e4tigten Absperrschiebern<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/what-is-an-axial-flow-silent-check-valve.html\/\">Was ist ein Axialr\u00fcckschlagventil<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/difference-between-gate-valve-and-butterfly-valve.html\/\">Unterschied zwischen Absperrschieber und Absperrklappe<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">Was ist ein Absperrschieber?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/de\/tag\/shanghai-pressure-reducing-valve-factory\/\">Shanghai Druckminderventilfabrik<\/a>\n\n<\/div>\n\n\n<p><\/p>\n<p>Zehn Artikel davor und danach<\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/hello-world.html\/\">Hallo Welt!<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/gate-valve-vs-butterfly-valve-comprehensive-compare-guide.html\/\">Umfassender Vergleichsleitfaden f\u00fcr Schieberventil und Absperrklappe<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/how-to-measure-butterfly-valves.html\/\">So messen Sie Absperrklappen<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/what-is-a-double-offset-butterfly-valve.html\/\">Was ist ein Doppel-Offset-Absperrventil<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/how-to-fix-a-leaking-butterfly-valve.html\/\">Wie repariert man ein undichtes Absperrventil?<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/pressure-reducing-valves-for-steam-opimization-zeco-valve-blog.html\/\">Druckminderventile zur Dampfoptimierung | Zeco Valve Blog<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/weld-in-place-ball-valves-a-unique-design-approach-zeco-valve-blog.html\/\">Einschwei\u00dfbare Kugelh\u00e4hne \u2013 Ein einzigartiger Designansatz | Zeco Valve Blog<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/a-fluid-velocity-tutorial-zeco-valve-blog.html\/\">Ein Tutorial zur Fl\u00fcssigkeitsgeschwindigkeit | Zeco Valve Blog<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/hydrostatic-tank-level-measurement-zeco-valve-blog.html\/\">Hydrostatische Tankf\u00fcllstandsmessung | Zeco Valve Blog<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/de\/resilient-seated-and-high-performance-butterfly-valves-zeco-valve-blog.html\/\">Absperrklappen mit elastischem Sitz und hoher Leistung | Zeco Valve Blog<\/a><\/p>\n<p><!-- \/wam:article --><\/p>","protected":false},"excerpt":{"rendered":"<p>In vielen Industrieanlagen m\u00fcssen verschiedene Ger\u00e4te sowie viele in Prozesssystemen verwendete Fl\u00fcssigkeiten gek\u00fchlt werden. Dies \u2026 <a title=\"Naturzugk\u00fchlturm und mechanischer Zugk\u00fchlturm\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/de\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\" aria-label=\"Mehr zu Naturzugk\u00fchlturm &amp; Mechanischer Zugk\u00fchlturm\">Weiterlesen ...<\/a><\/p>","protected":false},"author":2,"featured_media":26718,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2383,2150,2749,2382,2384,2381],"class_list":["post-2165","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-cooling-tower-types","tag-cooling-tower-valves","tag-cooling-tower-valves-suppliers","tag-induced-draft-cooling-tower","tag-mechanical-draft-cooling-tower","tag-natural-draft-cooling-tower","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/deltacooling-product.jpg",690,540,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/de\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2383,"name":"cooling tower types","slug":"cooling-tower-types","term_group":0,"term_taxonomy_id":2383,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2150,"name":"Cooling Tower Valves","slug":"cooling-tower-valves","term_group":0,"term_taxonomy_id":2150,"taxonomy":"post_tag","description":"<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET COOLING TOWER VALVES PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_24532c-4c\"} \/-->\r\n\r\n<!-- wp:heading -->\r\n<h2>What are Cooling Towers?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCooling towers are a critical need for any industrial and manufacturing operation. Their role in extracting heat and delivering it to the atmosphere through evaporative cooling leverages the principle of heat rejection. The essential element of a cooling tower is water that is delivered through a piping system. These steady flow devices cool the water by evaporation with direct contact with the air. Evaporatively cooled equipment like cooling towers typically utilizes a multi-cell configuration. While these systems offer improved efficiency, operational flexibility, and advanced controls, they can only perform as well as their hardware is designed and built. One of the most important components of a cooling tower is its valves.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-cooling-tower-valves\">Cooling Tower Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCooling tower valves are devices designed to control, regulate, distribute, and allow, or disallow the passage of water through certain parts of the cooling tower\u2019s system. The different valves throughout a cooling tower system play an important role in their performance and the overall operation of your facility. The types of valves needed will depend on the flow capacity and the size of the piping in the cooling tower. Temperature and pressure are also critical considerations when it comes to valve selection.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Choosing Cooling Tower Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nRegarding cooling systems, the valves that are selected typically are going to be flow control valves and isolation (shutoff and bypass) valves. There are important questions to consider before picking the valve for the cooling system.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe first thing to consider is the flow capacity. When considering the size required by the cooling application, it is easy to narrow down the valve that should be chosen. An important thing to remember in valve selection is the pipe size.\r\nWhat flow capacity is needed for the cooling system?\r\nWhat size piping will be used?\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nTemperature and pressure are the next critical pieces to look at when determining the control valves to use for a cooling system. The valve pressure\/temperature rating must be within the system design parameters. The first factor that should be considered is the maximum pressure that the cooling system is going to have to hold to determine the valve rating. Along with pressure comes the capacity of the system. Consider the following three options when examining the pressure level and relative capacity of the cooling system:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Small-diameter pipe (0.5 to 2\u201d): globe control valve<\/li>\r\n \t<li>Mid-diameter pipe (3 to 6\u201d): segmented ball valve<\/li>\r\n \t<li>Large-diameter pipe (8\u201d and above): high performance butterfly valve (HPBV)<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDifferent types of isolation valves also are considered based on pressure and related capacity:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Small-diameter pipe: two piece ball valve or three piece ball valve<\/li>\r\n \t<li>Mid-diameter pipe: 3 piece ball valve or flanged ball valve<\/li>\r\n \t<li>Large-diameter pipe: butterfly valve<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe capacity of the system as it relates to the diameter of the piping is an important aspect to consider when putting the cooling system together.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":4,"filter":"raw"},{"term_id":2749,"name":"Cooling Tower Valves Suppliers","slug":"cooling-tower-valves-suppliers","term_group":0,"term_taxonomy_id":2749,"taxonomy":"post_tag","description":"<!-- wp:paragraph -->\r\n\r\nCooling towers are a critical need for any industrial and manufacturing operation. Their role in extracting heat and delivering it to the atmosphere through evaporative cooling leverages the principle of heat rejection. The essential element of a cooling tower is water that is delivered through a piping system. These steady flow devices cool the water by evaporation with direct contact with the air. Evaporatively cooled equipment like cooling towers typically utilizes a multi-cell configuration. While these systems offer improved efficiency, operational flexibility, and advanced controls, they can only perform as well as their hardware is designed and built. One of the most important components of a cooling tower is its valves. This is why ZECO offers cooling tower valves to optimize the performance of your cooling towers, reduce downtime, and eliminate maintenance.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_7bd7e9-a7\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET COOLING TOWER VALVES PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-what-is-cooling-tower-valve\">What is Cooling Tower Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCooling tower valves are devices designed to control, regulate, distribute, and allow, or disallow the passage of water through certain parts of the cooling tower\u2019s system. The different valves throughout a cooling tower system play an important role in their performance and the overall operation of your facility. The types of valves needed will depend on the flow capacity and the size of the piping in the cooling tower. Temperature and pressure are also critical considerations when it comes to valve selection.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Features of Cooling Tower Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nZECO flow control valves have a simple &amp; reliable design and are available in the capacity range of 300 to 2200 m3\/h and size ranges of 150 to 300 NB. They are built specifically for cooling tower use and ensure low head losses. They are made of heavy-duty cast iron bodies and have a stainless steel valve stem. We also coat our control valves with a layer of the protective coating that resists corrosion.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Simple and reliable design<\/li>\r\n \t<li>Low head loss<\/li>\r\n \t<li>Heavy-duty cast iron body and stainless steel valve stem<\/li>\r\n \t<li>Available in the capacity range from 300 to 2200 CMH<\/li>\r\n \t<li>Size range 150 NB to 500 NB<\/li>\r\n \t<li>Special protective coatings available for corrosive atmosphere<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cooling Tower Valves Suppliers<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>Magnatrol Valve Corp.<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nManufacturer of two-way bronze &amp; stainless steel solenoid valves designed for standard applications in sizes from 3\/8 in. to 3 in. for pressures up to 500 PSIG. Also manufacturer of two-way solenoid valves in sizes from 1\/4 in. to 2 in. for pressures up to 15,000 PSIG. Rotary Style valves designed to handle dirty &amp; viscous liquids, constructed of stainless steel, Monel, Hastelloy C &amp; Titanium available 1\/2 in. to 6 in. Fire link valves &amp; latching valves are also available.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>DFT Inc.<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nManufacturer of custom and standard cooling tower distribution valves. Various types include wafer check, flanged, sanitary, and restrictor valves. Available in various sizes. Suitable for liquid, gas, or steam applications. Building maintenance, chemical processing, food, beverage, pharmaceutical, gas transmission, mining, petroleum refining, power generation, pulp and paper, and textiles industries served. Meets ASME and ANSI standards.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>ZECO Valve<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDistributor of steam specialty and fluid control devices. Products available include valves, pressure and temperature regulators, desuperheaters, noise reduction devices, steam separators and filters, condensate pump systems, steam traps, strainers, actuators, pneumatic controllers, pipe couplings, suction diffusers, condensate drains, steam filters, mufflers, pilots, noise suppressors, pressure transmitters, and unions. Steam traps, clean steam products, and cryogenic valves are also available.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":7,"filter":"raw"},{"term_id":2382,"name":"induced draft cooling tower","slug":"induced-draft-cooling-tower","term_group":0,"term_taxonomy_id":2382,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2384,"name":"mechanical draft cooling tower","slug":"mechanical-draft-cooling-tower","term_group":0,"term_taxonomy_id":2384,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2381,"name":"natural draft cooling tower","slug":"natural-draft-cooling-tower","term_group":0,"term_taxonomy_id":2381,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2383,"label":"cooling tower types"},{"value":2150,"label":"Cooling Tower Valves"},{"value":2749,"label":"Cooling Tower Valves Suppliers"},{"value":2382,"label":"induced draft cooling tower"},{"value":2384,"label":"mechanical draft cooling tower"},{"value":2381,"label":"natural draft cooling tower"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Natural Draft Cooling Tower &amp; Mechanical Draft Cooling Tower | ZECO<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/de\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\" \/>\n<meta property=\"og:locale\" content=\"de_DE\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Natural Draft Cooling Tower &amp; Mechanical Draft Cooling Tower | ZECO\" \/>\n<meta property=\"og:description\" content=\"In many industrial facilities, various pieces of equipment, as well as many fluids used in process systems need to be cooled.&nbsp; This ... Weiterlesen ...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/de\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-28T10:05:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-01T02:58:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/deltacooling-product.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"690\" \/>\n\t<meta property=\"og:image:height\" content=\"540\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Verfasst von\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Gesch\u00e4tzte Lesezeit\">\n\t<meta name=\"twitter:data2\" content=\"7\u00a0Minuten\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"de\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#primaryimage\",\"inLanguage\":\"de\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/deltacooling-product.jpg\",\"width\":690,\"height\":540},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\",\"name\":\"Natural Draft Cooling Tower & Mechanical Draft Cooling Tower | ZECO\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#primaryimage\"},\"datePublished\":\"2021-12-28T10:05:18+00:00\",\"dateModified\":\"2022-11-01T02:58:23+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#breadcrumb\"},\"inLanguage\":\"de\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\",\"url\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\",\"name\":\"Natural Draft Cooling Tower &#038; Mechanical Draft Cooling Tower\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/2165","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/comments?post=2165"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/posts\/2165\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media\/26718"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/media?parent=2165"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/categories?post=2165"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/de\/wp-json\/wp\/v2\/tags?post=2165"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}