{"id":16402,"date":"2022-06-21T04:50:01","date_gmt":"2022-06-21T04:50:01","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16402"},"modified":"2022-08-16T13:02:41","modified_gmt":"2022-08-16T13:02:41","slug":"advantages-disadvantages-and-application-scope-of-ball-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/es\/advantages-disadvantages-and-application-scope-of-ball-valve.html","title":{"rendered":"Ventajas Desventajas y \u00e1mbito de aplicaci\u00f3n de la v\u00e1lvula de bola"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"h-i-advantages-and-disadvantages-of-ball-valve\">I. Ventajas y desventajas de la v\u00e1lvula de bola.<\/h2>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-advantages-of-ball-valve\">1. Ventajas de la v\u00e1lvula de bola:<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>\u2460 Tiene la resistencia al flujo m\u00e1s baja (en realidad 0);<\/li><li>\u2461 Puede usarse de manera confiable en l\u00edquidos corrosivos de punto de ebullici\u00f3n medio y bajo porque no se puede atascar durante la operaci\u00f3n (cuando no hay lubricante);<\/li><li>\u2462 En un amplio rango de presi\u00f3n y temperatura, puede lograr un sellado completo;<\/li><li>\u2463 Puede realizar una apertura y cierre r\u00e1pidos, y el tiempo de apertura y cierre de algunas estructuras es de solo 0,05 ~ 0,1 s, para garantizar que se pueda utilizar en el sistema de automatizaci\u00f3n del banco de pruebas. Cuando la v\u00e1lvula se abre y cierra r\u00e1pidamente, no hay impacto durante la operaci\u00f3n;<\/li><li>\u2464 La parte de cierre esf\u00e9rica se puede colocar autom\u00e1ticamente en la posici\u00f3n l\u00edmite;<\/li><li>\u2465 El medio de trabajo deber\u00e1 estar sellado de forma fiable por ambos lados;<\/li><li>\u2466 Cuando la v\u00e1lvula est\u00e1 completamente abierta y cerrada, la superficie de sellado de la bola y el asiento de la v\u00e1lvula est\u00e1n aislados del medio, por lo que el medio que pasa a trav\u00e9s de la v\u00e1lvula a alta velocidad no provocar\u00e1 la erosi\u00f3n de la superficie de sellado;<\/li><li>\u2467 Tiene una estructura compacta y un peso liviano, por lo que puede considerarse como la estructura de v\u00e1lvula m\u00e1s razonable para sistemas de medio de baja temperatura;<\/li><li>\u2468 El cuerpo de la v\u00e1lvula es sim\u00e9trico, especialmente la estructura del cuerpo de la v\u00e1lvula soldada, que puede soportar bien la tensi\u00f3n de la tuber\u00eda;<\/li><li>\u2469 La v\u00e1lvula de bola con cuerpo de v\u00e1lvula completamente soldado se puede enterrar directamente en el suelo, de modo que las partes internas de la v\u00e1lvula no se corroan y la vida \u00fatil m\u00e1xima puede alcanzar los 30 a\u00f1os. Es la v\u00e1lvula m\u00e1s ideal para oleoductos y gasoductos.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-disadvantages-of-ball-valve\">2. Desventajas de la v\u00e1lvula de bola:<\/h3>\n\n\n\n<ul class=\"wp-block-list\"><li>\u2460 Debido a que el material del anillo de sellado principal del asiento de la v\u00e1lvula es politetrafluoroetileno, es inerte a casi todas las sustancias qu\u00edmicas y tiene las caracter\u00edsticas integrales de un coeficiente de fricci\u00f3n peque\u00f1o, un rendimiento estable, no envejece f\u00e1cilmente, una amplia gama de aplicaciones de temperatura y un excelente rendimiento de sellado. . Pero las caracter\u00edsticas f\u00edsicas del PTFE, incluido el alto coeficiente de expansi\u00f3n, la sensibilidad al flujo en fr\u00edo y la mala conductividad t\u00e9rmica, requieren que el dise\u00f1o del sello del asiento de la v\u00e1lvula se base en estas caracter\u00edsticas. Por lo tanto, cuando el material de sellado se endurece, se da\u00f1ar\u00e1 la fiabilidad del sello. Adem\u00e1s, el grado de resistencia a la temperatura del politetrafluoroetileno es bajo y solo se puede utilizar en condiciones inferiores a 180 \u2103. M\u00e1s all\u00e1 de esta temperatura, el material sellante envejecer\u00e1. Teniendo en cuenta el uso a largo plazo, generalmente no se utiliza a 120 \u2103.<\/li><li>\u2461 Su rendimiento de regulaci\u00f3n es peor que el de la v\u00e1lvula de compuerta, especialmente la v\u00e1lvula neum\u00e1tica (o v\u00e1lvula el\u00e9ctrica).<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-ii-application-scope-of-ball-valve\">II. \u00c1mbito de aplicaci\u00f3n de la v\u00e1lvula de bola:<\/h2>\n\n\n\n<p>Debido a la&nbsp;<a href=\"https:\/\/zecovalve.com\/es\/working-principle-and-structure-characteristics-of-ball-valve.html\/\">principio de funcionamiento de la v\u00e1lvula de bola<\/a>, es ampliamente utilizado en refinaci\u00f3n de petr\u00f3leo, oleoductos de larga distancia, industria qu\u00edmica, fabricaci\u00f3n de papel, industria farmac\u00e9utica, conservaci\u00f3n de agua, energ\u00eda el\u00e9ctrica, administraci\u00f3n municipal, acero y otras industrias.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Etiquetas relacionadas :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/\">V\u00e1lvula ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/gate-valve-problems.html\/\">Reparaci\u00f3n de v\u00e1lvulas de compuerta<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/difference-between-gate-valves-and-ball-valves.html\/\">V\u00e1lvula de compuerta frente a v\u00e1lvula de bola<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/introduction-of-epdm-nbr-butterfly-valve-seat-industrial-valve-information-news-zeco-valve.html\/\">V\u00e1lvula de mariposa de NBR<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/what-is-an-axial-flow-silent-check-valve.html\/\">Qu\u00e9 es una v\u00e1lvula antirretorno axial<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/producto\/manual-gate-valve\/\">v\u00e1lvula de compuerta de accionamiento manual Fabricantes<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/the-function-of-globe-valve-in-pipeline-system.html\/\">\u00bfQu\u00e9 son las v\u00e1lvulas de globo?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diferencia entre v\u00e1lvula de compuerta y v\u00e1lvula de mariposa<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">\u00bfQu\u00e9 es una v\u00e1lvula de compuerta?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/tag\/shanghai-pressure-reducing-valve-factory\/\">F\u00e1brica de v\u00e1lvulas reductoras de presi\u00f3n de Shanghai<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>I. Ventajas y desventajas de la v\u00e1lvula de bola 1. Ventajas de la v\u00e1lvula de bola: \u2460 Tiene la resistencia al flujo m\u00e1s baja (en realidad 0); \u2461\u2026 <a title=\"Ventajas Desventajas y \u00e1mbito de aplicaci\u00f3n de la v\u00e1lvula de bola\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/es\/advantages-disadvantages-and-application-scope-of-ball-valve.html\" aria-label=\"M\u00e1s en Ventajas Desventajas y \u00c1mbito de Aplicaci\u00f3n de la V\u00e1lvula de Bola\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2232,2075,2076,1841],"class_list":["post-16402","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-advantages-and-disadvantages-of-ball-valve","tag-advantages-of-ball-valve","tag-disadvantages-of-ball-valve","tag-how-to-open-a-stuck-ball-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/es\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2232,"name":"advantages and disadvantages of ball valve","slug":"advantages-and-disadvantages-of-ball-valve","term_group":0,"term_taxonomy_id":2232,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2075,"name":"advantages of ball valve","slug":"advantages-of-ball-valve","term_group":0,"term_taxonomy_id":2075,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"},{"term_id":2076,"name":"disadvantages of ball valve","slug":"disadvantages-of-ball-valve","term_group":0,"term_taxonomy_id":2076,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":1841,"name":"How to Open a Stuck Ball Valve","slug":"how-to-open-a-stuck-ball-valve","term_group":0,"term_taxonomy_id":1841,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_5caaaa-64\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"https:\/\/zecovalve.com\/contact\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>HOW TO OPEN A STUCK BALL VALVE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-what-causes-stuck-ball-valve\">What Causes Stuck <strong><mark class=\"has-inline-color has-contrast-2-color\" style=\"background-color: var(--base)\"><a href=\"https:\/\/zecovalve.com\/product-category\/ball-valve\" target=\"_blank\" rel=\"noreferrer noopener\">Ball Valve<\/a><\/mark><\/strong>?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nOne of the most common types of ball valve failures involves a buildup of dirt and sediment within the valve, making it difficult to open and close. The use of solvent cement glue can also clog up the ball, causing it to stick to the inside of the valve and resist turning. If this happens, you\u2019ll want to take the valve apart and clean out any grime you see.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nAnother frequent ball valve failure occurs when the elastic used to seal the valve (often in the form of an O-ring) gets worn down over time due to liquid or gas getting pushed through it. Since this is a natural symptom of use, you\u2019ll want to swap out the elastic when you notice cracks or leakage. Turning down the intensity of liquid flowing through the valve can also help extend the lifespan of the O-ring.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nAs the elastic starts to go, so too does the inner packing of the valve stem. Any scratching or damage to the valve stem requires someone to either replace the stem or the whole valve before the whole thing falls apart.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nMake sure to look for leak points at the nuts holding the bolts in as well. This indicates that the nuts are too loose or that the end connector needs realignment. Damage to O-rings around the nuts can also prove a culprit of these leaks.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>How to Open A Stuck Ball Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nBall valves are commonly used valves for main water and various branch shutoffs. This valve functions as an ON\/OFF valve which means that the valve should be either completely open allowing full flow, or completely closed, stopping the entire water flow. Occasionally, it may be necessary to loosen a ball valve because it is stuck or tight, thereby creating an obstruction to fluid flow. If a ball valve won\u2019t open, perform the following steps to rectify the issue:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li>Manual operation<\/li>\r\n \t<li>Turn off the main water supply.<\/li>\r\n \t<li>Then, loosen the valve by opening and closing it multiple times by turning its handle.<\/li>\r\n \t<li>Gently hammer the valve body multiple times on the valve body to break and free up the particles that are trapped between the ball and the valve body.<\/li>\r\n \t<li>Gently wiggle and rock the valve handle to help service the ball element and force it to move. Also, try to remove the valve handle and turn the valve a few times using a plier to help it move freely, and place the handle back on the valve using its screw. If these steps don\u2019t work, move on to step 2.<\/li>\r\n<\/ol>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:block {\"ref\":15781} \/-->\r\n\r\n<!-- wp:block {\"ref\":15788} \/-->\r\n\r\n<!-- wp:block {\"ref\":20648} \/-->\r\n\r\n<!-- wp:block {\"ref\":20644} \/-->\r\n\r\n<!-- wp:block {\"ref\":20646} \/-->\r\n\r\n<!-- wp:block {\"ref\":20641} \/-->\r\n\r\n<!-- wp:block {\"ref\":16760} \/-->\r\n\r\n<!-- wp:block {\"ref\":16233} \/-->\r\n\r\n<!-- wp:block {\"ref\":15809} \/-->\r\n\r\n<!-- wp:block {\"ref\":15797} \/-->","parent":0,"count":7,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2232,"label":"advantages and disadvantages of ball valve"},{"value":2075,"label":"advantages of ball valve"},{"value":2076,"label":"disadvantages of ball valve"},{"value":1841,"label":"How to Open a Stuck Ball Valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Advantages Disadvantages and Application Scope of Ball Valve - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/es\/advantages-disadvantages-and-application-scope-of-ball-valve.html\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Advantages Disadvantages and Application Scope of Ball Valve - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"I. Advantages and disadvantages of ball valve 1. Advantages of Ball Valve: \u2460 It has the lowest flow resistance (actually 0); \u2461 ... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/es\/advantages-disadvantages-and-application-scope-of-ball-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-21T04:50:01+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-16T13:02:41+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"2 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html\",\"name\":\"Advantages Disadvantages and Application Scope of Ball Valve - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-21T04:50:01+00:00\",\"dateModified\":\"2022-08-16T13:02:41+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html\",\"url\":\"https:\/\/zecovalve.com\/advantages-disadvantages-and-application-scope-of-ball-valve.html\",\"name\":\"Advantages Disadvantages and Application Scope of Ball Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/16402","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/comments?post=16402"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/16402\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/media?parent=16402"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/categories?post=16402"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/tags?post=16402"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}