{"id":16576,"date":"2022-06-22T05:29:17","date_gmt":"2022-06-22T05:29:17","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16576"},"modified":"2022-08-22T08:45:15","modified_gmt":"2022-08-22T08:45:15","slug":"difference-between-globe-valve-and-gate-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/es\/difference-between-globe-valve-and-gate-valve.html","title":{"rendered":"Diferencia entre v\u00e1lvula de globo y v\u00e1lvula de compuerta"},"content":{"rendered":"<p>La v\u00e1lvula de globo, la v\u00e1lvula de compuerta, la v\u00e1lvula de mariposa, la v\u00e1lvula de retenci\u00f3n y la v\u00e1lvula de bola son piezas de control indispensables en diversos sistemas de tuber\u00edas. Cada tipo de v\u00e1lvula es diferente en apariencia, estructura e incluso funci\u00f3n. Pero la v\u00e1lvula de globo y la v\u00e1lvula de compuerta son similares en apariencia y ambas tienen la funci\u00f3n de cortar la tuber\u00eda. Por lo que habr\u00e1 muchos amigos que al tener poco contacto con la v\u00e1lvula podr\u00e1n confundir la v\u00e1lvula de globo con la v\u00e1lvula de compuerta. De hecho, si lo observas con atenci\u00f3n, hay una gran diferencia entre la v\u00e1lvula de globo y la v\u00e1lvula de compuerta. Este art\u00edculo presentar\u00e1 el <a href=\"https:\/\/zecovalve.com\/es\/globe-valve-vs-gate-valve-difference-between-them-zeco.html\/\" data-internallinksmanager029f6b8e52c=\"11\" title=\"v\u00e1lvula de globo vs v\u00e1lvula de compuerta\" target=\"_blank\" rel=\"noopener\">diferencia entre v\u00e1lvula de globo y v\u00e1lvula de compuerta<\/a>.<\/p>\n\n\n\n\n\n<h2 class=\"wp-block-heading\">Diferencia estructural entre v\u00e1lvula de compuerta y v\u00e1lvula de globo<\/h2>\n\n\n\n<p>En caso de espacio de instalaci\u00f3n limitado, se deber\u00e1 prestar atenci\u00f3n a la selecci\u00f3n. El\u00a0<a href=\"https:\/\/zecovalve.com\/es\/products\/valvula-de-compuerta\/\">v\u00e1lvula de compuerta<\/a>\u00a0Se puede cerrar herm\u00e9ticamente con la superficie de sellado dependiendo de la presi\u00f3n media, para lograr el efecto de que no haya fugas. Si el n\u00facleo de la v\u00e1lvula est\u00e1 en contacto con la superficie de sellado del asiento de la v\u00e1lvula y hay fricci\u00f3n al abrir y cerrar, la superficie de sellado es f\u00e1cil de desgastar. Cuando la v\u00e1lvula de compuerta est\u00e1 cerrada, la diferencia de presi\u00f3n entre la parte delantera y trasera de la tuber\u00eda es grande, lo que hace que la superficie de sellado se desgaste m\u00e1s gravemente. La estructura de la v\u00e1lvula de compuerta ser\u00e1 m\u00e1s compleja que la de la v\u00e1lvula de globo. Desde la apariencia, bajo el mismo calibre, la v\u00e1lvula de compuerta es m\u00e1s alta que la v\u00e1lvula de globo y la v\u00e1lvula de globo es m\u00e1s larga que la v\u00e1lvula de compuerta. Adem\u00e1s, las v\u00e1lvulas de compuerta se dividen en v\u00e1stago abierto y v\u00e1stago oculto. La v\u00e1lvula de globo no se puede dividir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principio de funcionamiento de la v\u00e1lvula de globo y la v\u00e1lvula de compuerta.<\/h2>\n\n\n\n<p>Cuando el\u00a0<a href=\"https:\/\/zecovalve.com\/es\/products\/globe-valve-check-valve\/\">v\u00e1lvula de globo<\/a>\u00a0se abre y se cierra, es del tipo v\u00e1stago ascendente, lo que significa que al girar el volante girar\u00e1 y se levantar\u00e1 junto con el v\u00e1stago. La v\u00e1lvula de compuerta gira el volante de modo que el v\u00e1stago se mueve hacia arriba y hacia abajo, y la posici\u00f3n del volante permanece sin cambios. El caudal es diferente. Se requiere que la v\u00e1lvula de compuerta est\u00e9 completamente abierta o completamente cerrada, mientras que no se requiere la v\u00e1lvula de globo. La v\u00e1lvula de globo tiene direcciones de entrada y salida especificadas; la v\u00e1lvula de compuerta no tiene requisitos para las direcciones de entrada y salida. Adem\u00e1s, la v\u00e1lvula de compuerta solo tiene dos estados: completamente abierta o completamente cerrada. El recorrido de apertura y cierre de la puerta es muy grande y el tiempo de apertura y cierre es largo. La carrera de movimiento del plato de la v\u00e1lvula de globo es mucho m\u00e1s peque\u00f1a y el plato de la v\u00e1lvula de globo se puede detener en un lugar determinado durante el movimiento para regular el flujo. La v\u00e1lvula de compuerta solo se puede utilizar para truncamiento sin otras funciones.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Diferencia de rendimiento entre v\u00e1lvula de compuerta y v\u00e1lvula de globo<\/h2>\n\n\n\n<p>La v\u00e1lvula de globo se puede utilizar para corte y regulaci\u00f3n de flujo. La resistencia al flujo de la v\u00e1lvula de globo es relativamente grande y lleva tiempo abrirla y cerrarla. Sin embargo, la distancia entre el plato de v\u00e1lvula y la superficie de sellado es corta, por lo que la carrera de apertura y cierre es corta.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Instalaci\u00f3n y diferencia de direcci\u00f3n de flujo entre la v\u00e1lvula de compuerta y la v\u00e1lvula de globo<\/h2>\n\n\n\n<p>En t\u00e9rminos de direcci\u00f3n del flujo de la v\u00e1lvula de compuerta, el efecto es el mismo en ambas direcciones. No hay requisitos en cuanto a la direcci\u00f3n de entrada y salida para la instalaci\u00f3n, y el medio puede fluir en dos direcciones. La v\u00e1lvula de globo debe instalarse estrictamente de acuerdo con la direcci\u00f3n indicada por la flecha del cuerpo de la v\u00e1lvula. Existe una regulaci\u00f3n clara sobre la direcci\u00f3n de entrada y salida de la v\u00e1lvula de globo. Seg\u00fan la &quot;serializaci\u00f3n, universalizaci\u00f3n y estandarizaci\u00f3n&quot; de las v\u00e1lvulas de China, la direcci\u00f3n del flujo de la v\u00e1lvula de globo debe ser de arriba a abajo.<\/p>\n\n\n\n<p>Desde la perspectiva de la resistencia al flujo, cuando est\u00e1 completamente abierta, la resistencia al flujo de la v\u00e1lvula de compuerta es peque\u00f1a y la de la v\u00e1lvula de retenci\u00f3n de carga es grande. El coeficiente de resistencia al flujo de una v\u00e1lvula de compuerta ordinaria es de aproximadamente 0,08 ~ 0,12, la fuerza de apertura y cierre es peque\u00f1a y el medio puede fluir en dos direcciones.<\/p>\n\n\n\n<p>La v\u00e1lvula de corte es de entrada baja y salida alta. Por la apariencia, es obvio que la tuber\u00eda no est\u00e1 en la misma fase de la l\u00ednea horizontal. La ruta de flujo de la v\u00e1lvula de compuerta est\u00e1 en una l\u00ednea horizontal. La carrera de la v\u00e1lvula de compuerta es mayor que la de la v\u00e1lvula de globo. La resistencia al flujo de la v\u00e1lvula de globo com\u00fan es de 3 a 5 veces mayor que la de la v\u00e1lvula de compuerta. El elemento de v\u00e1lvula de la v\u00e1lvula de globo s\u00f3lo entra en contacto con la superficie de sellado cuando est\u00e1 completamente cerrado, por lo que el desgaste de la superficie de sellado es muy peque\u00f1o. La fuerza del flujo principal es grande y se necesita la v\u00e1lvula de globo del actuador, por lo que se debe prestar atenci\u00f3n al ajuste del mecanismo de control de torsi\u00f3n.<\/p>\n\n\n\n<p>Hay dos m\u00e9todos para instalar la v\u00e1lvula de globo: un m\u00e9todo es que el medio pueda ingresar desde la parte inferior del n\u00facleo de la v\u00e1lvula. El modelo de utilidad tiene las ventajas de que la empaquetadura no est\u00e1 bajo presi\u00f3n cuando la v\u00e1lvula est\u00e1 cerrada, la vida \u00fatil de la empaquetadura puede prolongarse y la empaquetadura puede reemplazarse cuando la tuber\u00eda frente a la v\u00e1lvula est\u00e1 bajo presi\u00f3n. La desventaja es que el par de accionamiento de la v\u00e1lvula es grande, que es aproximadamente 1 vez mayor que el flujo superior. La fuerza axial sobre el v\u00e1stago de la v\u00e1lvula es grande y el v\u00e1stago de la v\u00e1lvula es f\u00e1cil de doblar.<\/p>\n\n\n\n<p>Por lo tanto, este m\u00e9todo generalmente solo es aplicable a v\u00e1lvulas de globo de peque\u00f1o calibre (por debajo de DN50), y las v\u00e1lvulas de globo por encima de DN200 adoptan la forma en que el medio fluye desde arriba. (La v\u00e1lvula de globo el\u00e9ctrica generalmente adopta la forma en que el medio ingresa desde arriba). La desventaja de la entrada del medio desde arriba es opuesta a la de abajo.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-sealing-difference-between-gate-valve-and-globe-valve\">Diferencia de sellado entre v\u00e1lvula de compuerta y v\u00e1lvula de globo<\/h2>\n\n\n\n<p>La superficie de sellado de la v\u00e1lvula de globo es un peque\u00f1o lado trapezoidal del n\u00facleo de la v\u00e1lvula (depende espec\u00edficamente de la forma del n\u00facleo de la v\u00e1lvula). Una vez que el n\u00facleo de la v\u00e1lvula se cae, equivale a cerrar la v\u00e1lvula (si la diferencia de presi\u00f3n es grande, no se cerrar\u00e1 herm\u00e9ticamente, pero el efecto de verificaci\u00f3n es bueno). La v\u00e1lvula de compuerta est\u00e1 sellada por el costado del ariete del n\u00facleo de la v\u00e1lvula. Si el efecto de sellado no es tan bueno como el de la v\u00e1lvula de globo, la ca\u00edda del n\u00facleo de la v\u00e1lvula no ser\u00e1 equivalente a que la v\u00e1lvula se cierre como la v\u00e1lvula de globo.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Etiquetas relacionadas :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/\">V\u00e1lvula ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/gate-valve-problems.html\/\">Reparaci\u00f3n de v\u00e1lvulas de compuerta<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/difference-between-gate-valves-and-ball-valves.html\/\">V\u00e1lvula de compuerta frente a v\u00e1lvula de bola<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diferencia entre v\u00e1lvula de compuerta y v\u00e1lvula de mariposa<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/the-function-of-globe-valve-in-pipeline-system.html\/\">\u00bfQu\u00e9 son las v\u00e1lvulas de globo?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/advantages-and-disadvantages-of-globe-valves.html\/\">\u00bfQu\u00e9 es una v\u00e1lvula de globo?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">\u00bfQu\u00e9 es una v\u00e1lvula de compuerta?<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>La v\u00e1lvula de globo, la v\u00e1lvula de compuerta, la v\u00e1lvula de mariposa, la v\u00e1lvula de retenci\u00f3n y la v\u00e1lvula de bola son piezas de control indispensables en diversos sistemas de tuber\u00edas. Cada clase \u2026 <a title=\"Diferencia entre v\u00e1lvula de globo y v\u00e1lvula de compuerta\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/es\/difference-between-globe-valve-and-gate-valve.html\" aria-label=\"M\u00e1s en Diferencia entre v\u00e1lvula de globo y v\u00e1lvula de compuerta\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[1894,2323,3,1805],"class_list":["post-16576","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-advantages-and-disadvantages-of-globe-valves","tag-difference-between-globe-valve-and-gate-valve","tag-gate-valve","tag-globe-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/es\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":1894,"name":"Advantages and Disadvantages of Globe Valves","slug":"advantages-and-disadvantages-of-globe-valves","term_group":0,"term_taxonomy_id":1894,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_1f2967-98\"} \/-->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nA Globe valve is a linear motion valve and is primarily designed to stop, start and regulate flow. The disk of a Globe valve can be totally removed from the flow path or it can completely close the flow path.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET ADVANTAGES AND DISADVANTAGES OF GLOBE VALVES INFORMATION <\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-advantages-and-disadvantages-of-globe-valves\">Advantages and disadvantages of Globe valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>ADVANTAGES<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Good shutoff capability<\/li>\r\n \t<li>Moderate to good throttling capability<\/li>\r\n \t<li>Shorter stroke (compared to a gate valve)<\/li>\r\n \t<li>Available in tee, wye, and angle patterns, each offering unique capabilities<\/li>\r\n \t<li>Easy to machine or resurface the seats<\/li>\r\n \t<li>With the disc not attached to the stem, the valve can be used as a stop-check valve<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>DISADVANTAGES<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Higher pressure drop (compared to a gate valve)<\/li>\r\n \t<li>Requires greater force or a larger actuator to seat the valve (with pressure under the seat)<\/li>\r\n \t<li>Throttling flow under the seat and shutoff flow over the seat<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Flow direction of Globe Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nFor applications with low temperatures, Globe valves are normally installed so that the pressure is under the disc. This contributes to an easy operation and helps protect the packing.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nFor applications with high-temperature steam service, Globe valves are installed so that the pressure is above the disk. Otherwise, the stem will contract upon cooling and tend to lift the disk off the seat.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Typical Applications of Globe valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe following are some of the typical applications of Globe valves..\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Cooling water systems where flow needs to be regulated<\/li>\r\n \t<li>Fuel oil system where flow is regulated and leak tightness is of importance<\/li>\r\n \t<li>High-point vents and low-point drains when leak tightness and safety are major considerations<\/li>\r\n \t<li>Feedwater, chemical feed, condenser air extraction, and extraction drain systems<\/li>\r\n \t<li>Boiler vents and drains, main steam vents and drains, and heater drains<\/li>\r\n \t<li>Turbine seals and drains<\/li>\r\n \t<li>Turbine lube oil system and others<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->","parent":0,"count":6,"filter":"raw"},{"term_id":2323,"name":"difference between globe valve and gate valve","slug":"difference-between-globe-valve-and-gate-valve","term_group":0,"term_taxonomy_id":2323,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3,"name":"gate valve","slug":"gate-valve","term_group":0,"term_taxonomy_id":3,"taxonomy":"post_tag","description":"","parent":0,"count":41,"filter":"raw"},{"term_id":1805,"name":"globe valve","slug":"globe-valve","term_group":0,"term_taxonomy_id":1805,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":1894,"label":"Advantages and Disadvantages of Globe Valves"},{"value":2323,"label":"difference between globe valve and gate valve"},{"value":3,"label":"gate valve"},{"value":1805,"label":"globe valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Difference Between Globe Valve and Gate Valve - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/es\/difference-between-globe-valve-and-gate-valve.html\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Difference Between Globe Valve and Gate Valve - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Globe valve, gate valve, butterfly valve, check valve and ball valve are all indispensable control parts in various pipeline systems. Each kind ... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/es\/difference-between-globe-valve-and-gate-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-22T05:29:17+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-22T08:45:15+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"4 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html\",\"name\":\"Difference Between Globe Valve and Gate Valve - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-22T05:29:17+00:00\",\"dateModified\":\"2022-08-22T08:45:15+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html\",\"url\":\"https:\/\/zecovalve.com\/difference-between-globe-valve-and-gate-valve.html\",\"name\":\"Difference Between Globe Valve and Gate Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/16576","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/comments?post=16576"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/16576\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/media?parent=16576"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/categories?post=16576"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/tags?post=16576"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}