{"id":17213,"date":"2022-06-27T09:32:46","date_gmt":"2022-06-27T09:32:46","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17213"},"modified":"2022-10-18T14:03:42","modified_gmt":"2022-10-18T14:03:42","slug":"attentions-for-installation-of-auto-balancing-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/es\/attentions-for-installation-of-auto-balancing-valve.html","title":{"rendered":"Atenciones para la instalaci\u00f3n de v\u00e1lvulas de equilibrio autom\u00e1tico"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"h-1-installation-location-of-auto-balancing-valve\">1. Ubicaci\u00f3n de instalaci\u00f3n de <strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\"><a href=\"https:\/\/zecovalve.com\/es\/categoria-de-productos\/balancing-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">V\u00e1lvula de equilibrio autom\u00e1tico<\/a><\/mark><\/strong><\/h2>\n\n\n\n<p>La v\u00e1lvula de autoequilibrio se puede instalar en la tuber\u00eda de suministro de agua o en la tuber\u00eda de retorno de agua (solo una en cada circuito). Para el lado del circuito primario de la estaci\u00f3n t\u00e9rmica, para facilitar la depuraci\u00f3n del equilibrio, se recomienda instalar la v\u00e1lvula de equilibrio en la tuber\u00eda de retorno de agua con una temperatura del agua m\u00e1s baja. La v\u00e1lvula de equilibrio en la tuber\u00eda principal debe instalarse despu\u00e9s de la bomba de la tuber\u00eda principal de suministro de agua (aguas abajo de la bomba) para evitar la cavitaci\u00f3n de la bomba debido a la baja presi\u00f3n antes de la bomba (detr\u00e1s de la v\u00e1lvula).<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"600\" height=\"450\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/balancing-valve-installation.png\" alt=\"\" class=\"wp-image-26652\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/balancing-valve-installation.png 600w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/balancing-valve-installation-300x225.png 300w\" sizes=\"auto, (max-width: 600px) 100vw, 600px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-install-on-straight-pipe-as-far-as-possible\">2. Instale en un tubo recto en la medida de lo posible.<\/h2>\n\n\n\n<p>Debido a que la v\u00e1lvula de equilibrio tiene la funci\u00f3n de medir el flujo, para estabilizar el flujo a trav\u00e9s de la v\u00e1lvula y garantizar la precisi\u00f3n de la medici\u00f3n, la v\u00e1lvula de equilibrio debe instalarse en la secci\u00f3n de tuber\u00eda recta en la medida de lo posible cuando las condiciones lo permitan.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-pay-attention-to-the-balance-between-the-new-system-and-the-original-system\">3. Preste atenci\u00f3n al equilibrio entre el nuevo sistema y el sistema original.<\/h2>\n\n\n\n<p>Cuando se conecta un nuevo sistema con una v\u00e1lvula de equilibrio a la red de tuber\u00edas de calefacci\u00f3n (refrigeraci\u00f3n) original, se debe prestar atenci\u00f3n al equilibrio de la distribuci\u00f3n del agua entre el nuevo sistema y el sistema original, para evitar la resistencia al agua del nuevo sistema. (o el sistema reformado) con una v\u00e1lvula de equilibrio m\u00e1s alta que la del sistema original y no logra alcanzar el flujo de agua requerido.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-4-no-need-to-install-stop-valves\">4. No es necesario instalar <strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\"><a href=\"https:\/\/zecovalve.com\/es\/producto\/resilient-seated-gate-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">V\u00e1lvulas de cierre<\/a><\/mark><\/strong><\/h2>\n\n\n\n<p>Al inspeccionar un circuito, la v\u00e1lvula de equilibrio del circuito se puede cerrar. En este momento, la v\u00e1lvula de equilibrio desempe\u00f1a el papel de una v\u00e1lvula de corte para cortar el flujo de agua. Despu\u00e9s de la inspecci\u00f3n, la v\u00e1lvula de equilibrio puede volver a su posici\u00f3n bloqueada original. Por lo tanto, cuando se instala la v\u00e1lvula de equilibrio, no es necesario volver a instalar la v\u00e1lvula de cierre.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-5-when-adding-or-canceling-loops-the-system-should-be-readjusted\">5. Al agregar (o cancelar) bucles, se debe reajustar el sistema.<\/h2>\n\n\n\n<p>Al agregar (o cancelar) bucles en el sistema de red de tuber\u00edas, excepto agregar (o cerrar) las v\u00e1lvulas de equilibrio correspondientes, en principio se deben reajustar las v\u00e1lvulas de equilibrio completamente nuevas y las v\u00e1lvulas de equilibrio en los bucles del sistema original (v\u00e1lvulas de equilibrio derivadas en el sistema original). no es necesario reajustar el bucle).<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">6. Puesta en servicio<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Es aconsejable lavar el sistema hasta dejarlo limpio. Mantenga la v\u00e1lvula completamente abierta al lavar.<\/li><li>Si se requiere una prueba de presi\u00f3n del sistema, la presi\u00f3n m\u00e1xima permitida PS podr\u00e1 superarse hasta un m\u00e1ximo de 24 bar. Las pruebas de presi\u00f3n deben realizarse a temperatura ambiente y con la v\u00e1lvula completamente abierta.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">7. Medici\u00f3n: presi\u00f3n y caudal<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>\u00a1Preste mucha atenci\u00f3n durante la medici\u00f3n, en caso de medios calientes!<\/li><li>Los tapones de prueba de presi\u00f3n son autosellantes. Desenrosque el tap\u00f3n del tap\u00f3n de prueba de presi\u00f3n e inserte la sonda.<\/li><li>Atornille la tuerca anular de la sonda al tap\u00f3n de prueba de presi\u00f3n.<\/li><li>Recomendamos colocar una v\u00e1lvula de aislamiento aguas arriba de la sonda.<\/li><li>Despu\u00e9s de medir, desenrosque y extraiga la sonda. Vuelva a enroscar la tapa del tap\u00f3n.<\/li><li>Abra la v\u00e1lvula completamente (rotaci\u00f3n completa en sentido antihorario).<\/li><li>Atornille el man\u00f3metro conectado a los tapones de presi\u00f3n.<\/li><li>Gire el volante en el sentido de las agujas del reloj observando la conexi\u00f3n del man\u00f3metro. El indicador del man\u00f3metro es estable siempre que el caudal no cambie.<\/li><li>Deje de girar tan pronto como se mueva el indicador del man\u00f3metro (la presi\u00f3n diferencial aumenta).<\/li><li>Tome nota de la lectura de presi\u00f3n diferencial en el man\u00f3metro.<\/li><li>Calcule el caudal.<\/li><\/ul>\n\n\n\n<p>Para KVS detallados y coeficientes de flujo de v\u00e1lvulas de autoequilibrio, comun\u00edquese con <strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\"><a href=\"https:\/\/zecovalve.com\/es\/categoria-de-productos\/balancing-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">V\u00e1lvula ZECO<\/a><\/mark><\/strong>.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Etiquetas relacionadas :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/\">V\u00e1lvula ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/what-is-an-axial-flow-silent-check-valve.html\/\">Qu\u00e9 es una v\u00e1lvula antirretorno axial<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/categoria-de-productos\/balancing-valve\/\">V\u00e1lvula de equilibrado - V\u00e1lvula HVAC<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/es\/history-of-automatic-control-valve-zeco-valve-industrial-valve-manufacturer.html\/\">\u00bfQu\u00e9 son las v\u00e1lvulas autom\u00e1ticas de control?<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Ubicaci\u00f3n de instalaci\u00f3n de la v\u00e1lvula de equilibrio autom\u00e1tico La v\u00e1lvula de equilibrio autom\u00e1tico se puede instalar en la tuber\u00eda de suministro de agua o en... <a title=\"Atenciones para la instalaci\u00f3n de v\u00e1lvulas de equilibrio autom\u00e1tico\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/es\/attentions-for-installation-of-auto-balancing-valve.html\" aria-label=\"M\u00e1s en Atenci\u00f3n para la instalaci\u00f3n de v\u00e1lvulas de autoequilibrio\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":2,"featured_media":26652,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[2447],"tags":[3466,3465,2448,3464,2530,2560,2449],"class_list":["post-17213","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-balancing-valve","tag-auto-manual-balancing-valves","tag-auto-balancing-valves","tag-balancing-valve","tag-balancing-valve-installation","tag-balancing-valves","tag-dpcv","tag-static-balancing-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/balancing-valve-installation.png",600,450,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/es\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":2447,"name":"Balancing Valve","slug":"balancing-valve","term_group":0,"term_taxonomy_id":2447,"taxonomy":"category","description":"","parent":0,"count":21,"filter":"raw","cat_ID":2447,"category_count":21,"category_description":"","cat_name":"Balancing Valve","category_nicename":"balancing-valve","category_parent":0}],"tag_info":[{"term_id":3466,"name":"auto &amp; manual balancing valves","slug":"auto-manual-balancing-valves","term_group":0,"term_taxonomy_id":3466,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3465,"name":"auto balancing valves","slug":"auto-balancing-valves","term_group":0,"term_taxonomy_id":3465,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2448,"name":"Balancing valve","slug":"balancing-valve","term_group":0,"term_taxonomy_id":2448,"taxonomy":"post_tag","description":"","parent":0,"count":15,"filter":"raw"},{"term_id":3464,"name":"balancing valve installation","slug":"balancing-valve-installation","term_group":0,"term_taxonomy_id":3464,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2530,"name":"balancing valves","slug":"balancing-valves","term_group":0,"term_taxonomy_id":2530,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":2560,"name":"DPCV","slug":"dpcv","term_group":0,"term_taxonomy_id":2560,"taxonomy":"post_tag","description":"<!-- wp:paragraph -->\r\n\r\nTo meet the growing use of variable speed pumps for HVAC applications, ZECO Fluid Systems has launched a range of Differential Pressure Control Valves (DPCV) specifically aimed at optimizing system performance.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nExtremely efficient, the DPCV is set to a maximum differential pressure which ensures flow cannot exceed the desired rate. It, therefore, helps reduce energy consumption, and the risk of noise and simplifies the commissioning process.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_53a72f-f5\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET DCPV VALVE PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-what-is-dcpv\">What is DCPV?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDifferential Pressure Control Valves - also commonly called DPCVs - are installed in heating or cooling systems to control sub-circuit pressure to a set or given maximum.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nZECO\u2019s DPCV range includes three different types. A type with pre-set \u0394pC (differential pressure across the circuit), a type with adjustable \u0394pC, and finally a type being a combined dynamic balancing valve and adjustable DPCV. They offer a flexible range meeting any system demand.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>What is Differential Pressure Control?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nA differential pressure controller consists of a valve and a pressure actuator. Differential pressure controllers in the primary system are mainly used to keep a constant and lower differential pressure across a motorized control valve or a total system\/substation.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Specifications of DPCV<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Nominal diameter: DN25 \u2013 DN50<\/li>\r\n \t<li>Media temperature : -10\u00b0C to 120\u00b0C<\/li>\r\n \t<li>Pressure range: 16 bars- 25 bars<\/li>\r\n \t<li>Permissible medium\/application: Chilled\/hot water, Glycol solution, Cooling water<\/li>\r\n \t<li>Connection: Threaded BSP<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:image {\"align\":\"center\",\"id\":27252,\"width\":384,\"height\":512,\"sizeSlug\":\"large\",\"linkDestination\":\"none\"} -->\r\n<figure class=\"wp-block-image aligncenter size-large is-resized\"><img class=\"wp-image-27252\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/10\/DPCV-768x1024.jpg\" alt=\"DPCV\" width=\"384\" height=\"512\" \/><figcaption>DPCV<\/figcaption><\/figure>\r\n<!-- \/wp:image -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Nominal diameter: DN65 \u2013 DN250<\/li>\r\n \t<li>Media temperature : -10\u00b0C to 120\u00b0C<\/li>\r\n \t<li>Pressure range: 16 bars -25 bars<\/li>\r\n \t<li>Permissible medium\/application: Chilled\/hot water, Glycol solution, Cooling water<\/li>\r\n \t<li>Connection: RF<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:image {\"align\":\"center\",\"id\":17033,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\r\n<figure class=\"wp-block-image aligncenter size-full\"><img class=\"wp-image-17033\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/differential-pressure-control-valve.jpg\" alt=\"Differential Pressure Control Valve\" \/><\/figure>\r\n<!-- \/wp:image -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Why choose a DPCV?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nWith a DPCV installed in Your system, You will achieve reduced energy consumption, avoid the risk of annoying noise and have a simple commissioning process.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>How does a DPCV Work?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nA DPCV includes a diaphragm, a spring, and a capillary tube connecting the partner valve in the supply pipe and the DPCV valve in the return pipe to control the circuit pressure loss.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe differential pressure control valve (DPCV) is a special kind of control valve whose action is related to a measured pressure difference. In practice, the DPCV is used in several applications as will be further explained basically, its goal is to maintain a constant pressure difference across a certain part of the hydraulic network. Inside the DPCV, two cavities are separated by means of a membrane. One cavity is internally connected to the upstream side of the DPCV while the other one is connected to a remote location by means of a small capillary pipe. This way, the differential pressure across the membrane equals the pressure difference between the upstream measuring point and the DPCV. The resulting spindle travel depends on the force balance between the membrane and the spring.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\n\u2022 \u0394P Control\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe DPCV diaphragm will regulate to control \u0394pC (differential pressure across the circuit) depending on pressure impulse from the supply side and direct pressure from the return side. The spring force will equal the \u0394pC.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nIn all ZECO DPCVs, the diaphragm will be a rolling diaphragm which will result in a very compact valve design. Depending on the ZECO Differential Pressure Control Valve selected, \u0394pC may be fixed or externally adjustable.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":12,"filter":"raw"},{"term_id":2449,"name":"Static balancing valve","slug":"static-balancing-valve","term_group":0,"term_taxonomy_id":2449,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"}],"taxonomy_info":{"category":[{"value":2447,"label":"Balancing Valve"}],"post_tag":[{"value":3466,"label":"auto &amp; manual balancing valves"},{"value":3465,"label":"auto balancing valves"},{"value":2448,"label":"Balancing valve"},{"value":3464,"label":"balancing valve installation"},{"value":2530,"label":"balancing valves"},{"value":2560,"label":"DPCV"},{"value":2449,"label":"Static balancing valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Attentions for Auto Balancing Valve Installation | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/es\/attentions-for-installation-of-auto-balancing-valve.html\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Attentions for Auto Balancing Valve Installation | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"1. Installation location of Auto Balancing Valve The auto balancing valve can be installed in the water supply pipeline or in the ... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/es\/attentions-for-installation-of-auto-balancing-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T09:32:46+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-10-18T14:03:42+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/balancing-valve-installation.png\" \/>\n\t<meta property=\"og:image:width\" content=\"600\" \/>\n\t<meta property=\"og:image:height\" content=\"450\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"2 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/balancing-valve-installation.png\",\"width\":600,\"height\":450},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html\",\"name\":\"Attentions for Auto Balancing Valve Installation | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html#primaryimage\"},\"datePublished\":\"2022-06-27T09:32:46+00:00\",\"dateModified\":\"2022-10-18T14:03:42+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html\",\"url\":\"https:\/\/zecovalve.com\/attentions-for-installation-of-auto-balancing-valve.html\",\"name\":\"Attentions for Auto Balancing Valve Installation\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/17213","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/comments?post=17213"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/17213\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/media\/26652"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/media?parent=17213"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/categories?post=17213"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/tags?post=17213"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}