{"id":17317,"date":"2022-06-27T13:23:19","date_gmt":"2022-06-27T13:23:19","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17317"},"modified":"2022-08-03T16:11:59","modified_gmt":"2022-08-03T16:11:59","slug":"zeco-valve-test-system","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/es\/zeco-valve-test-system.html","title":{"rendered":"Sistema de prueba de v\u00e1lvulas Zeco"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"h-1-valve-flow-characteristic-test\">1. Prueba de caracter\u00edstica de flujo de v\u00e1lvula<\/h2>\n\n\n\n<p>Instale la v\u00e1lvula de prueba en la posici\u00f3n correspondiente de la tuber\u00eda de acuerdo con su tama\u00f1o, inicie el convertidor de frecuencia para hacer que su frecuencia aumente de acuerdo con la velocidad especificada, la velocidad de la bomba aumenta, la diferencia de presi\u00f3n en ambos lados de la v\u00e1lvula cambia en consecuencia y obtenga al mismo tiempo el valor de caudal correspondiente. Cuando la diferencia de presi\u00f3n entre los dos lados de la v\u00e1lvula alcanza su diferencia de presi\u00f3n m\u00e1xima o la frecuencia de funcionamiento alcanza los 50 HZ, el convertidor de frecuencia se desacelera y se detiene autom\u00e1ticamente. Se registraron los datos del sensor de flujo y del sensor de presi\u00f3n diferencial y se dibuj\u00f3 la curva caracter\u00edstica de flujo de presi\u00f3n diferencial para completar el experimento. HIGO. 1 muestra los resultados de la prueba de la curva caracter\u00edstica de flujo de la v\u00e1lvula de equilibrio de flujo.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"300\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png\" alt=\"\" class=\"wp-image-17318\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3-300x225.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<p>Figura 1: curva diferencial de presi\u00f3n-flujo de la v\u00e1lvula de equilibrio de flujo<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-valve-opening-characteristic-test\">2 \u3001 Prueba de caracter\u00edstica de apertura de v\u00e1lvula<\/h2>\n\n\n\n<p>Instale el regulador con actuador en la tuber\u00eda, ajuste la apertura de la v\u00e1lvula para ajustar el flujo y controle la diferencia de presi\u00f3n entre los dos extremos de la v\u00e1lvula a 100 kPa para obtener la curva caracter\u00edstica de flujo abierto. Ver figura 2.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"300\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-4.png\" alt=\"\" class=\"wp-image-17319\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-4.png 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-4-300x225.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<p>Figura 2: Curva de flujo abierto<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-valve-flow-coefficient-valve-resistance-coefficient-test\">3. Coeficiente de flujo de la v\u00e1lvula, prueba del coeficiente de resistencia de la v\u00e1lvula.<\/h2>\n\n\n\n<p>La diferencia de presi\u00f3n entre los dos extremos de la v\u00e1lvula de agua se controla a 100 kPa y en este momento se mide el caudal de la v\u00e1lvula. El coeficiente de flujo se puede obtener usando la f\u00f3rmula (1) y el coeficiente de resistencia se puede calcular mediante la f\u00f3rmula (2), donde V es el caudal de la tuber\u00eda de la v\u00e1lvula, calculado mediante la f\u00f3rmula (3), y D es el di\u00e1metro nominal. de la v\u00e1lvula. Despu\u00e9s de que el procedimiento anterior ingresa a la opci\u00f3n de prueba, la computadora genera autom\u00e1ticamente el informe.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-4-pressure-regulating-test-of-pressure-reducing-valve-and-pressure-differential-valve\">4 \u3001 Prueba de regulaci\u00f3n de presi\u00f3n de la v\u00e1lvula reductora de presi\u00f3n y la v\u00e1lvula diferencial de presi\u00f3n<\/h2>\n\n\n\n<p>El banco de pruebas se puede utilizar para probar la presi\u00f3n de salida y el flujo y la curva de presi\u00f3n de entrada del <a href=\"https:\/\/zecovalve.com\/es\/water-pressure-reducing-valve-manufacturer-zeco-valve.html\/\" data-internallinksmanager029f6b8e52c=\"8\" title=\"V\u00e1lvula reductora de presi\u00f3n\" target=\"_blank\" rel=\"noopener\">v\u00e1lvula reductora de presi\u00f3n<\/a>;La diferencia de presi\u00f3n entre los dos extremos de la v\u00e1lvula de control de presi\u00f3n diferencial y la curva de variaci\u00f3n del flujo y la presi\u00f3n de entrada se pueden medir utilizando la mesa experimental.<\/p>","protected":false},"excerpt":{"rendered":"<p>1. Prueba de caracter\u00edsticas de flujo de la v\u00e1lvula Instale la v\u00e1lvula de prueba en la posici\u00f3n correspondiente de la tuber\u00eda de acuerdo con su tama\u00f1o, inicie la frecuencia... <a title=\"Sistema de prueba de v\u00e1lvulas Zeco\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/es\/zeco-valve-test-system.html\" aria-label=\"M\u00e1s en Sistema de prueba de v\u00e1lvulas Zeco\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[153,40,5],"class_list":["post-17317","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-flow","tag-pressure","tag-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/es\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":153,"name":"flow","slug":"flow","term_group":0,"term_taxonomy_id":153,"taxonomy":"post_tag","description":"","parent":0,"count":26,"filter":"raw"},{"term_id":40,"name":"pressure","slug":"pressure","term_group":0,"term_taxonomy_id":40,"taxonomy":"post_tag","description":"","parent":0,"count":6,"filter":"raw"},{"term_id":5,"name":"valve","slug":"valve","term_group":0,"term_taxonomy_id":5,"taxonomy":"post_tag","description":"","parent":0,"count":118,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":153,"label":"flow"},{"value":40,"label":"pressure"},{"value":5,"label":"valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Zeco Valve Test System - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/es\/zeco-valve-test-system.html\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Zeco Valve Test System - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"1\u3001Valve Flow Characteristic Test Install the test valve in the corresponding position of the pipeline according to its size, start the frequency ... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/es\/zeco-valve-test-system.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T13:23:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-03T16:11:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"1 minuto\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#primaryimage\",\"inLanguage\":\"es\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png\",\"width\":400,\"height\":300},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\",\"name\":\"Zeco Valve Test System - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#primaryimage\"},\"datePublished\":\"2022-06-27T13:23:19+00:00\",\"dateModified\":\"2022-08-03T16:11:59+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\",\"url\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\",\"name\":\"Zeco Valve Test System\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/17317","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/comments?post=17317"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/17317\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/media?parent=17317"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/categories?post=17317"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/tags?post=17317"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}