{"id":17383,"date":"2022-06-27T14:03:39","date_gmt":"2022-06-27T14:03:39","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17383"},"modified":"2022-08-03T16:10:16","modified_gmt":"2022-08-03T16:10:16","slug":"water-pump-control-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/es\/water-pump-control-valve.html","title":{"rendered":"V\u00e1lvula de control de bomba de agua"},"content":{"rendered":"<p>La v\u00e1lvula de control de la bomba de agua es una v\u00e1lvula multifunci\u00f3n que utiliza el modo piloto para controlar el flujo. Es adecuado para tuber\u00edas con caudal y presi\u00f3n a controlar en tuber\u00edas de distribuci\u00f3n. Mantiene el flujo predeterminado sin cambios, limita el flujo excesivo a un valor predeterminado y reduce adecuadamente la alta presi\u00f3n aguas arriba. <\/p>\n\n\n\n<p>Incluso si la presi\u00f3n aguas arriba de la v\u00e1lvula principal cambia, no afectar\u00e1 el flujo aguas abajo de la v\u00e1lvula principal.<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>1. Cambie el principio de la v\u00e1lvula de control de la bomba de agua convencional de usar placa de orificio o maquinaria pura para reducir el \u00e1rea del dep\u00f3sito de drenaje y use v\u00e1lvulas piloto relacionadas para minimizar la p\u00e9rdida de energ\u00eda en el proceso de estrangulamiento.<\/li><li>2. La sensibilidad del control es alta, segura y confiable, la depuraci\u00f3n es simple y la vida \u00fatil es larga.<\/li><\/ul>\n\n\n\n<p>La v\u00e1lvula de control de la bomba de agua puede equilibrar autom\u00e1ticamente el flujo del sistema sin una fuente de alimentaci\u00f3n externa. El caudal se limita manteniendo la diferencia de presi\u00f3n entre la parte delantera y trasera de la placa de orificio (di\u00e1metro de orificio fijo), por lo que tambi\u00e9n se le puede llamar v\u00e1lvula de flujo constante.<\/p>\n\n\n\n<p>La v\u00e1lvula de control de la bomba de agua act\u00faa sobre el caudal, lo que puede bloquear el flujo de agua a trav\u00e9s de la v\u00e1lvula, en lugar de sobre el equilibrio de la resistencia. Puede resolver el problema de desequilibrio din\u00e1mico del sistema: para mantener el funcionamiento eficiente de un solo refrigerador, caldera, torre de enfriamiento e intercambiador de calor, es necesario controlar el caudal de estos dispositivos para que se fije en el valor nominal; Desde el final del sistema, para evitar la interacci\u00f3n del ajuste din\u00e1mico, tambi\u00e9n es necesario limitar el dispositivo final o rama. Control de flujo.<\/p>\n\n\n\n<p>En dise\u00f1o, el inconveniente de\u00a0<strong>v\u00e1lvula de control de la bomba de agua<\/strong>\u00a0es que la v\u00e1lvula tiene el requisito de error de funcionamiento m\u00ednimo. El producto general requiere una diferencia de presi\u00f3n de trabajo m\u00ednima de 20 KPa. Si se instala en el circuito m\u00e1s desventajoso, es necesario aumentar la altura de trabajo de la bomba de circulaci\u00f3n en 2 metros. Por lo tanto, se debe adoptar la instalaci\u00f3n proximal y alterar la instalaci\u00f3n distal. M\u00e9todo. Cuando la distancia entre el usuario y la fuente de calor es superior a 80% del radio de calentamiento, no se debe instalar la v\u00e1lvula de control de flujo.<\/p>","protected":false},"excerpt":{"rendered":"<p>La v\u00e1lvula de control de la bomba de agua es una v\u00e1lvula multifunci\u00f3n que utiliza el modo piloto para controlar el flujo. Es adecuado para tuber\u00edas con flujo... <a title=\"V\u00e1lvula de control de bomba de agua\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/es\/water-pump-control-valve.html\" aria-label=\"M\u00e1s en V\u00e1lvula de control de bomba de agua\">Leer m\u00e1s<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[168,153,5],"class_list":["post-17383","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-control","tag-flow","tag-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/es\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":168,"name":"control","slug":"control","term_group":0,"term_taxonomy_id":168,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":153,"name":"flow","slug":"flow","term_group":0,"term_taxonomy_id":153,"taxonomy":"post_tag","description":"","parent":0,"count":25,"filter":"raw"},{"term_id":5,"name":"valve","slug":"valve","term_group":0,"term_taxonomy_id":5,"taxonomy":"post_tag","description":"","parent":0,"count":116,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":168,"label":"control"},{"value":153,"label":"flow"},{"value":5,"label":"valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Water Pump Control Valve - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/es\/water-pump-control-valve.html\" \/>\n<meta property=\"og:locale\" content=\"es_ES\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Water Pump Control Valve - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Water pump control valve is a multi-function valve which uses pilot mode to control flow. It is suitable for pipes with flow ... Leer m\u00e1s\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/es\/water-pump-control-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T14:03:39+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-03T16:10:16+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tiempo de lectura\">\n\t<meta name=\"twitter:data2\" content=\"1 minuto\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"es\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/water-pump-control-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/water-pump-control-valve.html\",\"name\":\"Water Pump Control Valve - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-27T14:03:39+00:00\",\"dateModified\":\"2022-08-03T16:10:16+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/water-pump-control-valve.html#breadcrumb\"},\"inLanguage\":\"es\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/water-pump-control-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/water-pump-control-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/water-pump-control-valve.html\",\"url\":\"https:\/\/zecovalve.com\/water-pump-control-valve.html\",\"name\":\"Water Pump Control Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/17383","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/comments?post=17383"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/posts\/17383\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/media?parent=17383"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/categories?post=17383"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/es\/wp-json\/wp\/v2\/tags?post=17383"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}