{"id":14170,"date":"2022-01-08T10:49:43","date_gmt":"2022-01-08T10:49:43","guid":{"rendered":"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html"},"modified":"2022-11-05T09:10:10","modified_gmt":"2022-11-05T09:10:10","slug":"difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/fr\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html","title":{"rendered":"Qu&#039;est-ce qu&#039;une vanne \u00e0 double blocage et purge ? DBB contre DIB"},"content":{"rendered":"<p>Le double blocage et purge (DBB) consiste \u00e0 fermer une section de tuyau des deux c\u00f4t\u00e9s de la vanne plut\u00f4t qu&#039;une seule. Cela signifie que vous fermez les vannes \u00e0 bille pour bloquer les c\u00f4t\u00e9s amont et aval de votre zone de travail, puis que vous purgez toute pression restant dans la tuyauterie et la vanne.<\/p>\n\n\n\n\n\n<h2 class=\"wp-block-heading\"><strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\"><a href=\"https:\/\/zecovalve.com\/fr\/categorie-de-produits\/ball-valve\/\">Vanne de blocage et de purge double (vannes DBB)<\/a><\/mark><\/strong><\/h2>\n\n\n\n<p>Ces vannes remplacent les techniques traditionnelles utilis\u00e9es par les ing\u00e9nieurs de pipelines pour g\u00e9n\u00e9rer une configuration \u00e0 double blocage et purge dans le pipeline. Deux vannes de sectionnement et une vanne de purge constituent une unit\u00e9 ou un collecteur \u00e0 installer pour une isolation positive. Utilis\u00e9es pour le service de processus critiques, les vannes DBB sont destin\u00e9es aux syst\u00e8mes haute pression ou aux processus de fluides toxiques\/dangereux. Les applications qui utilisent les vannes DBB incluent la vidange des instruments, la connexion d&#039;injection chimique, l&#039;isolation du joint chimique et l&#039;isolation de la jauge. Les vannes DBB effectuent le travail de trois vannes s\u00e9par\u00e9es (2 isolations et 1 vidange) et n\u00e9cessitent moins d&#039;espace et moins de poids.<\/p>\n\n\n\n<p>La vanne \u00e0 double blocage et purge ou un DBBV peut effectuer les t\u00e2ches de 3 vannes s\u00e9par\u00e9es (2 isolations s\u00e9par\u00e9es et 1 vanne de vidange) qui, en plus d&#039;\u00eatre extr\u00eamement peu encombrantes, peuvent \u00e9galement \u00e9conomiser du poids et du temps en raison des pratiques d&#039;installation et de maintenance n\u00e9cessitant beaucoup moins de travail. et l&#039;op\u00e9rateur peut localiser et faire fonctionner les 3 vannes en un seul endroit.<\/p>\n\n\n\n<p>Les vannes \u00e0 double blocage et purge fonctionnent sur le principe selon lequel l&#039;isolation peut \u00eatre obtenue \u00e0 la fois du d\u00e9bit\/pression du proc\u00e9d\u00e9 en amont et en aval.<\/p>\n\n\n\n<p>Une fois l&#039;isolation r\u00e9alis\u00e9e dans une ou plusieurs des principales vannes d&#039;isolation du proc\u00e9d\u00e9, la cavit\u00e9 cr\u00e9\u00e9e entre ces isolations peut \u00eatre vidang\u00e9e. Ceci est utile pour les situations de d\u00e9viation de d\u00e9bit, d&#039;\u00e9chantillonnage ou d&#039;injection, ainsi que pour les situations de maintenance et\/ou de contr\u00f4le d&#039;int\u00e9grit\u00e9 o\u00f9 les fuites du si\u00e8ge peuvent \u00eatre surveill\u00e9es via la troisi\u00e8me vanne de \u00ab purge \u00bb.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"454\" height=\"334\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/valve_dbb.jpg\" alt=\"\" class=\"wp-image-16223\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/valve_dbb.jpg 454w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/valve_dbb-300x221.jpg 300w\" sizes=\"auto, (max-width: 454px) 100vw, 454px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Pourquoi utiliser une vanne \u00e0 double blocage et purge ?<\/h2>\n\n\n\n<p>Les vannes \u00e0 double blocage et de purge ont \u00e9volu\u00e9 pour remplacer le processus de boulonnage des vannes individuelles pour fournir une double isolation.<\/p>\n\n\n\n<p>Ce nouvel ensemble permet de r\u00e9aliser d&#039;importantes \u00e9conomies en termes de poids, d&#039;espace et de temps d&#039;installation, notamment en mati\u00e8re d&#039;isolation des instruments ou des cages d&#039;instruments. Ces \u00e9conomies peuvent atteindre le poids du 60% et des \u00e9tudes ont montr\u00e9 qu&#039;un gain de temps d&#039;installation du 70% est \u00e9galement possible. Toutefois, les \u00e9conomies les plus importantes r\u00e9sident dans la r\u00e9duction des chemins de fuite vers l&#039;atmosph\u00e8re, r\u00e9duisant ainsi le risque de dangers potentiels que cela implique.<\/p>\n\n\n\n<p>La double isolation est une exigence n\u00e9cessaire lorsque la maintenance a lieu en aval de la premi\u00e8re vanne d&#039;isolation. La ventilation de la cavit\u00e9 est assur\u00e9e par une vanne de ventilation \u00e0 bille ou \u00e0 globe afin que la pression emprisonn\u00e9e entre les deux vannes d&#039;isolement soit \u00e9vacu\u00e9e en toute s\u00e9curit\u00e9.<\/p>\n\n\n\n<p>Ces vannes ont \u00e9galement \u00e9volu\u00e9 pour englober la fonction d&#039;injection de produits chimiques (\u00e0 l&#039;aide d&#039;une plume appropri\u00e9e) et de points d&#039;\u00e9chantillonnage. Des clapets anti-retour int\u00e9gr\u00e9s sont souvent int\u00e9gr\u00e9s \u00e0 ces vannes.<\/p>\n\n\n\n<p>Toutes les vannes DBB sont fabriqu\u00e9es selon la derni\u00e8re r\u00e9vision EEMUA 182.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"601\" height=\"495\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/valve_dbb_system.gif\" alt=\"\" class=\"wp-image-16225\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Pourquoi utiliser une vanne \u00e0 double isolation et purge ?<\/h2>\n\n\n\n<p>Les vannes \u00e0 double isolation et purge, comme leur nom l&#039;indique, sont la solution id\u00e9ale lorsqu&#039;une isolation absolue est n\u00e9cessaire. Par exemple, dans des situations telles que\u00a0:<\/p>\n\n\n\n<p>Une section du processus est en cours de maintenance et un fluide \u00e0 pression\/temp\u00e9rature extr\u00eamement \u00e9lev\u00e9e se trouve dans le flux en amont.<\/p>\n\n\n\n<p>Dans les industries agroalimentaires o\u00f9 une fermeture est requise, tout type de contamination entre les flux amont et aval doit \u00eatre \u00e9vit\u00e9.<\/p>\n\n\n\n<p>Il y a un probl\u00e8me \u00e0 r\u00e9soudre ici. Le corps de la vanne ne peut pas se lib\u00e9rer de l&#039;accumulation de pression car aucune fonction de purge n&#039;est utilis\u00e9e dans les si\u00e8ges. Le si\u00e8ge en amont risque d&#039;\u00eatre endommag\u00e9 ou de fuir, et la pression s&#039;accumule dans le corps de la vanne. Ainsi, une m\u00e9thode de purge alternative, int\u00e9gr\u00e9e au corps de la vanne, est n\u00e9cessaire pour \u00e9viter une nouvelle accumulation de pression et des dommages potentiels au corps de la vanne.<\/p>\n\n\n\n<p>Lorsque la s\u00e9curit\u00e9 est n\u00e9cessaire lors de l&#039;arr\u00eat du processus, que ce soit pour des raisons de s\u00e9curit\u00e9 ou de contamination du produit, une vanne DIB peut \u00eatre la solution la plus efficace. C&#039;est pourquoi les DIB sont souvent utilis\u00e9s dans les applications agroalimentaires et les applications volatiles comme le p\u00e9trole, le gaz et la vapeur.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principales caract\u00e9ristiques du double bloc et de la vanne de purge<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Test de s\u00e9curit\u00e9 incendie approuv\u00e9\u00a0<ul><li>Les vannes Double Block &amp; Bleed sont con\u00e7ues conform\u00e9ment aux normes API 607 et API SPEC 6FA. Joint double corps<\/li><li>Toutes les vannes Double Block &amp; Bleed sont \u00e9quip\u00e9es de deux joints de corps. Le premier joint de corps est en mat\u00e9riau souple et le second en graphite (si cela n&#039;est pas requis autrement), cette combinaison assure les meilleures caract\u00e9ristiques d&#039;\u00e9tanch\u00e9it\u00e9 quel que soit le service corrosif tout en offrant une conception ignifuge.<\/li><\/ul><\/li><li>Dispositif antistatique<ul><li>Afin d&#039;\u00e9viter l&#039;\u00e9lectricit\u00e9 statique qui pourrait enflammer le fluide, un ressort de conduction statique est plac\u00e9 entre la tige et la bille.<\/li><\/ul><\/li><li>Tige anti-\u00e9clatement<ul><li>La tige est con\u00e7ue avec un \u00e9paulement int\u00e9gral de type T pour fournir une protection efficace contre l&#039;\u00e9ruption. La conception garantit que la tige ne peut pas \u00eatre souffl\u00e9e hors de la vanne en cas de retrait de la garniture alors que la vanne est sous pression.<\/li><\/ul><\/li><li>Finition contr\u00f4l\u00e9e de la tige et du presse-\u00e9toupe<ul><li>L\u2019usinage de finition des tiges et des presse-\u00e9toupes est un point de contr\u00f4le cl\u00e9. La tige est r\u00e9alis\u00e9e par laminage \u00e0 froid et la finition de la surface de la tige est contr\u00f4l\u00e9e par Ra=0,4, ce qui peut r\u00e9duire le frottement du mouvement de la tige et assurer l&#039;\u00e9tanch\u00e9it\u00e9. La surface du presse-\u00e9toupe est contr\u00f4l\u00e9e dans Ra=1,6 pour de meilleures performances d&#039;\u00e9tanch\u00e9it\u00e9.<\/li><\/ul><\/li><li>Balle solide<ul><li>La bille solide utilis\u00e9e par ZECO offre un d\u00e9bit direct et de v\u00e9ritables caract\u00e9ristiques de performance \u00e0 port complet. Les billes creuses ou les billes \u00e0 cavit\u00e9 fourr\u00e9e ne sont pas utilis\u00e9es pour les produits ZECO.<\/li><\/ul><\/li><li>Long\u00e9vit\u00e9 de la vie<ul><li>Une attention particuli\u00e8re a \u00e9t\u00e9 consacr\u00e9e \u00e0 l&#039;am\u00e9lioration de la dur\u00e9e de vie et du fonctionnement de notre vanne tout au long des \u00e9tapes de conception, de d\u00e9veloppement, de test et de fabrication.<\/li><li>La conception des vannes combin\u00e9e \u00e0 la s\u00e9lection de mat\u00e9riaux avanc\u00e9s est telle que de longues p\u00e9riodes d&#039;inactivit\u00e9 ne devraient pas affecter l&#039;efficacit\u00e9 des op\u00e9rations.<\/li><\/ul><\/li><li>faible couple de sortie<ul><li>La conception des si\u00e8ges, les syst\u00e8mes de roulements de tige et les dispositions de joints de tige garantissent des valeurs de couple minimales constantes.<\/li><\/ul><\/li><li>Capacit\u00e9 de d\u00e9bit<ul><li>La conception de la vanne permet une capacit\u00e9 de d\u00e9bit \u00e9lev\u00e9e dans les services de liquides ou de gaz, que le fluide soit propre ou sale. Les vannes \u00e0 passage int\u00e9gral permettent <a href=\"https:\/\/zecovalve.com\/fr\/understanding-pigging-and-pig-valves-in-industrial-pipelines-zeco-valve-blog.html\/\" data-internallinksmanager029f6b8e52c=\"12\" title=\"raclage\" target=\"_blank\" rel=\"noopener\">raclage<\/a> et assurer une capacit\u00e9 de d\u00e9bit maximale.<\/li><\/ul><\/li><li>Bride ISO int\u00e9gr\u00e9e \u00e0 la conception du corps<ul><li>Le montage ISO 5211 est toujours int\u00e9gr\u00e9 \u00e0 la vanne en version standard.<\/li><\/ul><\/li><li>Dispositif de verrouillage<ul><li>Un dispositif de verrouillage est fourni en standard afin d&#039;emp\u00eacher toute ouverture\/fermeture non autoris\u00e9e. Le dispositif de verrouillage ZECO peut verrouiller la vanne en position ouverte ou ferm\u00e9e et ne peut pas \u00eatre viol\u00e9 en retirant le levier.<\/li><\/ul><\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-dbb-vs-dib\">DBB contre DIB<span id=\"hits\"><\/span><\/h2>\n\n\n\n<p>Avec une vanne DBB, il y a g\u00e9n\u00e9ralement deux si\u00e8ges auto-soulag\u00e9s unidirectionnels. Ces si\u00e8ges ne d\u00e9pendent pas d\u2019un m\u00e9canisme ext\u00e9rieur pour soulager la pression. En revanche, une vanne DIB utilise un ou deux si\u00e8ges bidirectionnels. La vanne offre une double isolation de la pression aux deux extr\u00e9mit\u00e9s de la vanne, mais ne peut pas \u00e9vacuer la pression de la cavit\u00e9 corporelle au-del\u00e0 des si\u00e8ges. Les vannes DIB n\u00e9cessitent un syst\u00e8me de d\u00e9charge externe pour soulager l&#039;accumulation de pression.<\/p>\n\n\n\n<p>Les deux vannes peuvent assurer une isolation dans les directions amont et aval, m\u00eame dans des situations de haute pression ou de haute temp\u00e9rature. L&#039;isolation est importante dans les cas o\u00f9 une fuite \u00e0 travers une vanne pourrait avoir des cons\u00e9quences majeures. Une fois le fluide isol\u00e9, le m\u00e9canisme de purge peut drainer la zone situ\u00e9e entre les deux vannes ou les deux surfaces d&#039;appui. Ceci est important pour les situations de maintenance et de contr\u00f4le d\u2019int\u00e9grit\u00e9 o\u00f9 les fuites peuvent \u00eatre surveill\u00e9es.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">VANNE \u00c0 BILLE DBB<\/h3>\n\n\n\n<p>Selon la d\u00e9finition API 6D, la section 3.1.10 d\u00e9finit une vanne \u00e0 double blocage et purge comme : \u00ab Vanne unique avec deux surfaces d&#039;\u00e9tanch\u00e9it\u00e9 qui, en position ferm\u00e9e, assure l&#039;\u00e9tanch\u00e9it\u00e9 contre les pressions des deux extr\u00e9mit\u00e9s de la vanne avec un moyen de ventilation\/purge de la cavit\u00e9 entre les si\u00e8ges.<br>Pour y parvenir, la vanne est \u00e9quip\u00e9e de deux si\u00e8ges SPE, comme nous l&#039;avons vu.<\/p>\n\n\n\n<p>La conception \u00e0 double blocage et purge est la plus couramment utilis\u00e9e pour les vannes \u00e0 tourillon, responsables d&#039;environ 85% d&#039;applications p\u00e9troli\u00e8res et gazi\u00e8res mondiales. Il s&#039;agit d&#039;une vanne compacte et l\u00e9g\u00e8re qui offre une isolation fiable dans les zones critiques, r\u00e9duisant ainsi les besoins en tuyauterie. Pour r\u00e9sumer, un DBB est une vanne qui ferme dans les deux sens avec une purge entre les deux, si le premier joint fuit, le second ne fermera pas dans le m\u00eame sens et ne n\u00e9cessite pas de m\u00e9canisme externe pour rel\u00e2cher la pression. Une vanne DBB implique une double s\u00e9curit\u00e9, assurant une s\u00e9curit\u00e9 dans deux directions diff\u00e9rentes, chacune avec un joint s\u00e9par\u00e9. Lorsqu&#039;une vanne DBB est utilis\u00e9e et que le premier joint fuit, le deuxi\u00e8me joint ne fermera pas dans la m\u00eame direction.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">VANNE \u00c0 BILLE DIB<\/h3>\n\n\n\n<p>La section 3.1.11 de la d\u00e9finition API 6D d\u00e9finit une vanne \u00e0 double isolation et purge comme : \u00ab Vanne simple avec deux surfaces d&#039;appui, dont chacune, en position ferm\u00e9e, assure l&#039;\u00e9tanch\u00e9it\u00e9 contre la pression provenant d&#039;une source unique, avec un des moyens de ventilation\/purge de la cavit\u00e9 entre les surfaces d&#039;\u00e9tanch\u00e9it\u00e9. Cette fonctionnalit\u00e9 peut \u00eatre fournie dans un sens ou dans les deux sens.<\/p>\n\n\n\n<p>Dans les d\u00e9finitions DBB et DIB de l&#039;API, la diff\u00e9rence r\u00e9side dans le fait qu&#039;une vanne \u00e0 double blocage et purge assure l&#039;\u00e9tanch\u00e9it\u00e9 contre les pressions des deux c\u00f4t\u00e9s de la vanne, tandis qu&#039;une vanne \u00e0 double isolation et purge fournit une \u00e9tanch\u00e9it\u00e9 suppl\u00e9mentaire contre l&#039;accumulation de pression dans la cavit\u00e9 de la vanne.<\/p>\n\n\n\n<p>Deux configurations sont disponibles pour les robinets \u00e0 tournant sph\u00e9rique DIB\u00a0:\u00a0DIB-1 et DIB-2. La configuration DIB-1 comprend des si\u00e8ges bidirectionnels en amont et en aval. La conception du robinet \u00e0 bille DIB-2 comprend un si\u00e8ge bidirectionnel (DPE) et un si\u00e8ge unidirectionnel (SPE).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">VANNE \u00c0 SPH\u00c8RE DIB-1<\/h3>\n\n\n\n<p>Les robinets \u00e0 tournant sph\u00e9rique DIB-1 sont dot\u00e9s de si\u00e8ges DPE en amont et en aval pour assurer une \u00e9tanch\u00e9it\u00e9 dans les deux sens. Pour la configuration DIB-1, la surpressurisation de la cavit\u00e9 est \u00e9vit\u00e9e gr\u00e2ce \u00e0 l&#039;utilisation d&#039;une soupape de d\u00e9charge externe. Avec la bille en position ferm\u00e9e et la pression du c\u00f4t\u00e9 amont, la pression dans la cavit\u00e9 augmentera en cas de d\u00e9faillance du si\u00e8ge amont. La pression de la cavit\u00e9 provoquera un double effet piston sur le si\u00e8ge aval cr\u00e9ant un deuxi\u00e8me joint sur la bille.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\">VANNE \u00c0 SPH\u00c8RE DIB-2<\/h3>\n\n\n\n<p>Pour la configuration DIB-2, un si\u00e8ge SPE et l&#039;autre DPE, la surpressurisation de la cavit\u00e9 est contr\u00f4l\u00e9e en interne au sein de la ligne. Si le si\u00e8ge en amont fuit, il y a alors une d\u00e9compression automatique de la cavit\u00e9 du c\u00f4t\u00e9 amont et le si\u00e8ge en aval assurera l&#039;isolation gr\u00e2ce \u00e0 l&#039;effet de double piston.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Avantages et inconv\u00e9nients de DBB\/DIB-1\/DIB-2<\/h2>\n\n\n\n<p>Le principal avantage du robinet \u00e0 tournant sph\u00e9rique DBB est qu&#039;il est dot\u00e9 de si\u00e8ges auto-soulag\u00e9s. Cependant, si le si\u00e8ge amont fuit, le si\u00e8ge aval ne fournira pas d&#039;isolation. D&#039;un autre c\u00f4t\u00e9, le principal avantage du DIB est que m\u00eame en cas de fuite du si\u00e8ge amont, le deuxi\u00e8me si\u00e8ge assurera l&#039;\u00e9tanch\u00e9it\u00e9 et la vanne ne fuira pas. Il convient de noter que le robinet \u00e0 tournant sph\u00e9rique DIB doit \u00eatre \u00e9quip\u00e9 de soupapes de d\u00e9charge dans la cavit\u00e9 du corps. Si nous voulons combiner les caract\u00e9ristiques positives des vannes DIB-1 et DBB, nous devons alors utiliser la vanne DIB-2 qui a un si\u00e8ge SPE en amont et un si\u00e8ge DPE en aval. Si le si\u00e8ge amont fuit dans le DIB-2, la pression de la cavit\u00e9 peut alors se rel\u00e2cher du c\u00f4t\u00e9 amont et le si\u00e8ge aval assurera l&#039;isolation gr\u00e2ce \u00e0 l&#039;effet double piston. Il convient de noter que l&#039;installation du robinet \u00e0 tournant sph\u00e9rique DIB-2 est critique et que le si\u00e8ge SPE doit \u00eatre du c\u00f4t\u00e9 amont\/pressuris\u00e9.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong><span style=\"font-size: 14px;\">Comparaison entre la structure du robinet \u00e0 bille DBB\/DIB-1\/DIB-2\u00a0\uff1b (uniquement pour <strong>robinet \u00e0 tournant sph\u00e9rique<\/strong> construction)<\/span><\/strong><\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">\u00a0Diff\u00e9rence de structure DBB\/DIB-1\/DIB-2<\/h2>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Non<\/strong><\/td><td><strong>Type de structure<\/strong><\/td><td><strong>Nom de la structure<\/strong><\/td><td><strong>Principe d&#039;\u00e9chappement<\/strong><\/td><td><strong>Application du produit<\/strong><\/td><\/tr><tr><td>1<\/td><td>DBB&nbsp;<\/td><td>Effet piston unique<br>Double blocage et saignement et \u00e9coulement de la cavit\u00e9 moyenne<\/td><td>D\u00e9compression automatique dans la cavit\u00e9 centrale, pression dans les deux c\u00f4t\u00e9s du canal<\/td><td>La structure la plus fr\u00e9quemment utilis\u00e9e \u00e0 l\u2019heure actuelle\u00a0;<\/td><\/tr><tr><td>2<\/td><td>DIB-1<\/td><td>Effet double piston<br>Double blocage et double saignement<\/td><td>La d\u00e9compression ne peut \u00eatre obtenue que gr\u00e2ce \u00e0 une soupape de surpression suppl\u00e9mentaire, la pression ne p\u00e9n\u00e8tre pas par les c\u00f4t\u00e9s<\/td><td>Utilisation dans des conditions de travail sp\u00e9cifiques ou selon les exigences du client\u00a0;<\/td><\/tr><tr><td>3<\/td><td>DIB-2<\/td><td>Effet piston simple\/double<br>Double blocage et avant vanne de d\u00e9charge<\/td><td>D\u00e9charge automatique devant la vanne, pression uniquement dans le canal d&#039;entr\u00e9e<\/td><td>Lorsqu&#039;elle est utilis\u00e9e pour rel\u00e2cher la pression, la pression ne doit pas entrer dans l&#039;\u00e9tat en aval du pipeline.<br>Vanne avec le sens d&#039;\u00e9coulement, faites attention au sens d&#039;installation\u00a0;<br>\u00c0 l&#039;heure actuelle, il est mieux accept\u00e9 par de nombreux propri\u00e9taires\u00a0;<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Balises associ\u00e9es :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/\">Soupape ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valves-and-ball-valves.html\/\">Vanne et robinet \u00e0 boisseau sph\u00e9rique<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/introduction-of-epdm-nbr-butterfly-valve-seat-industrial-valve-information-news-zeco-valve.html\/\">Robinet \u00e0 papillon NBR<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-axial-flow-silent-check-valve.html\/\">Qu'est-ce qu'un clapet anti-retour axial ?<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/gate-valve-problems.html\/\">R\u00e9paration de vannes \u00e0 vanne<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/advantages-and-disadvantages-of-globe-valves.html\/\">Qu'est-ce qu'un robinet \u00e0 soupape ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/produit\/manual-gate-valve\/\">Fabricant de robinets-vannes \u00e0 commande manuelle<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/the-function-of-globe-valve-in-pipeline-system.html\/\">Que sont les vannes \u00e0 soupape\u00a0?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diff\u00e9rence entre la vanne \u00e0 vanne et la vanne papillon<\/a>\n\n<\/div>\n\n\n\n<p>Dix articles avant et apr\u00e8s<\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/what-is-v-port-control-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Qu&#039;est-ce que le robinet \u00e0 tournant sph\u00e9rique de contr\u00f4le du port V \u2013 Actualit\u00e9s \u2013 Chine Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique - Robinet \u00e0 tournant sph\u00e9rique | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/titanium-and-titanium-alloy-ball-valve-application-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Application de robinets \u00e0 tournant sph\u00e9rique en titane et en alliage de titane \u2013 Actualit\u00e9s \u2013 Fabricant, usine et fournisseur de robinets \u00e0 tournant sph\u00e9rique en Chine | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/difference-in-full-bore-ball-valve-and-reduced-bore-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Diff\u00e9rence entre le robinet \u00e0 tournant sph\u00e9rique \u00e0 passage int\u00e9gral et le robinet \u00e0 tournant sph\u00e9rique \u00e0 passage r\u00e9duit \u2013 Actualit\u00e9s \u2013 Chine Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique - Robinet \u00e0 tournant sph\u00e9rique | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/top-5-ball-valve-manufacturers-in-china-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Top 5 des fabricants de robinets \u00e0 tournant sph\u00e9rique en Chine \u2013 Actualit\u00e9s \u2013 Fabricant, usine et fournisseur de robinets \u00e0 tournant sph\u00e9rique en Chine | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/difference-between-ptfe-lined-ball-valve-and-pfa-lined-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Diff\u00e9rence entre le robinet \u00e0 tournant sph\u00e9rique rev\u00eatu de PTFE et le robinet \u00e0 tournant sph\u00e9rique rev\u00eatu de PFA \u2013 Actualit\u00e9s \u2013 Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique en Chine | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/how-does-a-cryogenic-ball-valve-work-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Comment fonctionne un robinet \u00e0 tournant sph\u00e9rique cryog\u00e9nique \u2013 Actualit\u00e9s \u2013 Chine Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/what-is-a-ceramic-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Qu&#039;est-ce qu&#039;un robinet \u00e0 tournant sph\u00e9rique en c\u00e9ramique \u2013 Actualit\u00e9s \u2013 Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique en Chine | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/double-block-and-bleed-valve-introduction-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Introduction des vannes \u00e0 double bloc et de purge \u2013 Actualit\u00e9s \u2013 Chine Fabricant, usine et fournisseur de vannes \u00e0 bille | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/what-is-the-jacketed-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">Qu&#039;est-ce que le robinet \u00e0 tournant sph\u00e9rique \u00e0 chemise \u2013 Actualit\u00e9s \u2013 Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique en Chine | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/fr\/the-difference-between-metal-seat-ball-valve-and-soft-seat-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\/\">La diff\u00e9rence entre le robinet \u00e0 tournant sph\u00e9rique \u00e0 si\u00e8ge m\u00e9tallique et le robinet \u00e0 tournant sph\u00e9rique \u00e0 si\u00e8ge souple \u2013 Actualit\u00e9s \u2013 Fabricant, usine et fournisseur de robinet \u00e0 tournant sph\u00e9rique en Chine | Fabricant de robinets \u00e0 tournant sph\u00e9rique API 6D<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Le double blocage et purge (DBB) est la pratique consistant \u00e0 fermer une section de tuyau des deux c\u00f4t\u00e9s de la vanne plut\u00f4t que\u2026 <a title=\"Qu&#039;est-ce qu&#039;une vanne \u00e0 double blocage et purge ? DBB contre DIB\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/fr\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\" aria-label=\"Plus sur Qu&#039;est-ce qu&#039;une vanne \u00e0 double blocage et purge ? DBB contre DIB\">Lire plus<\/a><\/p>","protected":false},"author":2,"featured_media":20746,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[3927,2142,3924,3925,2143,3923,3926,3928,2141,3277,2144],"class_list":["post-14170","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-china-dbb-ball-valve","tag-dbb-valve","tag-dbb-vs-dib","tag-dib-ball-valve","tag-dib-valve","tag-dib-valves","tag-dib-vs-dbb","tag-dib-2-valve","tag-double-block-and-bleed-valve","tag-intec-duoball-valve","tag-single-block-and-bleed-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/valve_dbb.jpg",454,334,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/fr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":3927,"name":"china dbb ball valve","slug":"china-dbb-ball-valve","term_group":0,"term_taxonomy_id":3927,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2142,"name":"DBB valve","slug":"dbb-valve","term_group":0,"term_taxonomy_id":2142,"taxonomy":"post_tag","description":"","parent":0,"count":4,"filter":"raw"},{"term_id":3924,"name":"dbb vs dib","slug":"dbb-vs-dib","term_group":0,"term_taxonomy_id":3924,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3925,"name":"dib ball valve","slug":"dib-ball-valve","term_group":0,"term_taxonomy_id":3925,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2143,"name":"DIB valve","slug":"dib-valve","term_group":0,"term_taxonomy_id":2143,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3923,"name":"dib valves","slug":"dib-valves","term_group":0,"term_taxonomy_id":3923,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3926,"name":"dib vs dbb","slug":"dib-vs-dbb","term_group":0,"term_taxonomy_id":3926,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3928,"name":"dib-2 valve","slug":"dib-2-valve","term_group":0,"term_taxonomy_id":3928,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2141,"name":"double block and bleed valve","slug":"double-block-and-bleed-valve","term_group":0,"term_taxonomy_id":2141,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":3277,"name":"INTEC Duoball Valve","slug":"intec-duoball-valve","term_group":0,"term_taxonomy_id":3277,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_3a9674-b3\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET INTEC DUOBALL VALVE PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-intec-duoball-valve\">INTEC Duoball Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe Duo ball valve, developed by KLINGER Sch\u00f6neberg, has a double shut-off of the pipeline and makes it possible to increase the safety of a system significantly. The Duo ball valve is available in the same length as a standard valve and provides a compact and economical alternative to several valves.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe Duo Ball Valve (DBV) is designed for applications with extremely high safety requirements. The DBV consists of two ball valves, which are equipped on request with two independent barriers. Therefore, the safety factor could be increased 4 times compared to a standard ball valve. Due to the double isolation and bleed function each ball valve is tight on both the upstream and downstream sides.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Features of INTEC Duoball Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul><!-- wp:list-item -->\r\n \t<li>Compared to standard ball valves, the safety can be increased by a factor of 4.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>The design is based on the integration of two ball valves in one body.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Like all ball valves of the INTEC series, the Duoball valve is available with a floating ball or trunnion mounted ball as well as soft or metal seated execution<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>All ball seat systems naturally fulfill the leakage rate A according to EN 12266 and are absolutely gas-tight.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- wp:list-item -->\r\n<ul>\r\n \t<li style=\"list-style-type: none\">\r\n<ul>\r\n \t<li>Due to the double insulation and venting function, every duoball valve is bi-directionally tight.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<!-- \/wp:list-item -->\r\n\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>What is DBB Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nA double block and bleed valve are like having three valves in one.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nAPI 6D defines a double block and bleed valve as a \"single valve with two seating surfaces that, in the closed position, provides a seal against pressure from both ends of the valve with a means of venting\/bleeding the cavity between the seating surfaces.\"\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThere are a couple of different styles of double block and bleed valves. One style has two independently seating valves inside, with a bleed or drains valve. This configuration is referred to as a double isolation and bleed (DIB). The DIB valve can isolate either side of the valve (bi-directionally) to vent or bleed the cavity and isolate piping.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThis trunnion style ball valve from ZECO provides a double block and bleed in a single valve. This style can isolate piping on both sides of the valve (uni-directionally) to vent\/bleed the valve cavity between the seats.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nUsing a single double block and bleed valve system versus 3 separate valves saves installation time, weight on the piping system, and space. It also cuts down the number of leak paths to the atmosphere, reducing the risk of hazards when transferring liquids dangerous to humans or the environment.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Features and Benefits of DBB Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDouble Block and Bleed valves have been developed to substitute the process of bolting the individual valves together to provide dual insulation.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThis new model provides excellent savings in weight, space, and installation time, particularly for insulation in the instrument or instrument cage. These weight savings will amount to up to 60% and tests have shown that a time savings of 70% on installation is also possible. The biggest benefits must be seen, however, in reducing the leakage pathways into the environment, thus reducing the possibility of possible dangers.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDual isolation is an essential requirement when maintenance is performed downstream of the first isolation valve. Cavity venting is given by either a ball or a globe vent valve such that the compressed pressure between the two isolation valves is vented safely.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThese valves have also grown to incorporate the role of chemical injection and sampling points. In-built control valves are also incorporated into these valves.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":4,"filter":"raw"},{"term_id":2144,"name":"single block and bleed valve","slug":"single-block-and-bleed-valve","term_group":0,"term_taxonomy_id":2144,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":3927,"label":"china dbb ball valve"},{"value":2142,"label":"DBB valve"},{"value":3924,"label":"dbb vs dib"},{"value":3925,"label":"dib ball valve"},{"value":2143,"label":"DIB valve"},{"value":3923,"label":"dib valves"},{"value":3926,"label":"dib vs dbb"},{"value":3928,"label":"dib-2 valve"},{"value":2141,"label":"double block and bleed valve"},{"value":3277,"label":"INTEC Duoball Valve"},{"value":2144,"label":"single block and bleed valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>DBB Valve and DIB Valve - DBB vs DIB | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/fr\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"DBB Valve and DIB Valve - DBB vs DIB | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Double block and bleed (DBB) is&nbsp;the practice of shutting in a section of pipe on both sides of the valve rather than ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/fr\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-01-08T10:49:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-05T09:10:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/valve_dbb.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"454\" \/>\n\t<meta property=\"og:image:height\" content=\"334\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\">\n\t<meta name=\"twitter:data2\" content=\"9 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/valve_dbb.jpg\",\"width\":454,\"height\":334},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\",\"name\":\"DBB Valve and DIB Valve - DBB vs DIB | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html#primaryimage\"},\"datePublished\":\"2022-01-08T10:49:43+00:00\",\"dateModified\":\"2022-11-05T09:10:10+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\",\"url\":\"https:\/\/zecovalve.com\/difference-between-dib-ball-valve-and-dbb-ball-valve-news-china-ball-valve-manufacturerfactory-and-supplier-ball-valve-api-6d-ball-valve-manufacturer.html\",\"name\":\"What is a Double Block and Bleed Valve? DBB vs DIB\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/14170","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/comments?post=14170"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/14170\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media\/20746"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media?parent=14170"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/categories?post=14170"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/tags?post=14170"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}