{"id":16064,"date":"2022-06-18T13:36:55","date_gmt":"2022-06-18T13:36:55","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16064"},"modified":"2022-09-16T02:29:20","modified_gmt":"2022-09-16T02:29:20","slug":"reasons-for-long-neck-cover-used-in-cryogenic-ball-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/fr\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html","title":{"rendered":"Raisons pour lesquelles un couvercle \u00e0 col long est utilis\u00e9 dans les robinets \u00e0 tournant sph\u00e9rique cryog\u00e9niques"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Qu&#039;est-ce qu&#039;une vanne cryog\u00e9nique ?<\/h2>\n\n\n\n<p>Les vannes cryog\u00e9niques sont des vannes qui peuvent \u00eatre utilis\u00e9es \u00e0 basse temp\u00e9rature. G\u00e9n\u00e9ralement, les vannes sont trait\u00e9es comme des vannes cryog\u00e9niques lorsque la temp\u00e9rature de fonctionnement est inf\u00e9rieure \u00e0 -40 \u00b0C. <\/p>\n\n\n\n<p>Les vannes cryog\u00e9niques sont souvent utilis\u00e9es dans le secteur du p\u00e9trole, du gaz, de la s\u00e9paration de l&#039;air, du gaz naturel industriel, etc. La qualit\u00e9 d\u00e9termine que si elles peuvent fonctionner de mani\u00e8re s\u00fbre, \u00e9conomique et continue. Avec le d\u00e9veloppement de la technologie moderne, les exigences en mati\u00e8re de vannes cryog\u00e9niques augmentent de plus en plus et les plages d&#039;utilisation sont consid\u00e9rablement \u00e9largies.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Qu&#039;est-ce qu&#039;un <a href=\"https:\/\/zecovalve.com\/fr\/produit\/cryogenic-ball-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\"><strong><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\">Robinet \u00e0 bille cryog\u00e9nique<\/mark><\/strong><\/a>?<\/h2>\n\n\n\n<p>Les vannes \u00e0 bille cryog\u00e9niques, comme leur nom l&#039;indique, sont des vannes \u00e0 bille utilis\u00e9es dans des applications extr\u00eamement froides.<\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-1024x1024.jpg\" alt=\"\" class=\"wp-image-19492\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-1024x1024.jpg 1024w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-300x300.jpg 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-150x150.jpg 150w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-768x768.jpg 768w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-1536x1536.jpg 1536w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-2048x2048.jpg 2048w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-400x400.jpg 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-600x600.jpg 600w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-100x100.jpg 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-1024x1024.jpg\" alt=\"\" class=\"wp-image-19494\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-1024x1024.jpg 1024w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-300x300.jpg 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-150x150.jpg 150w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-768x768.jpg 768w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-1536x1536.jpg 1536w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-2048x2048.jpg 2048w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-400x400.jpg 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-600x600.jpg 600w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-3-100x100.jpg 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\">\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1024\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-1024x1024.jpg\" alt=\"\" class=\"wp-image-19493\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-1024x1024.jpg 1024w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-300x300.jpg 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-150x150.jpg 150w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-768x768.jpg 768w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-1536x1536.jpg 1536w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-2048x2048.jpg 2048w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-400x400.jpg 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-600x600.jpg 600w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-2-100x100.jpg 100w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n<\/div>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-long-neck-cover-design-used-in-cryogenic-ball-valve\">Conception de couvercle \u00e0 col long utilis\u00e9e dans les robinets \u00e0 tournant sph\u00e9rique cryog\u00e9niques<\/h2>\n\n\n\n<p>Les vannes adapt\u00e9es aux temp\u00e9ratures moyennes allant de \u2013 40 C \u00e0 \u2013 196 C sont appel\u00e9es vannes cryog\u00e9niques, et ces vannes utilisent g\u00e9n\u00e9ralement un chapeau \u00e0 long col. Les vannes basse temp\u00e9rature sp\u00e9cifi\u00e9es par un couvercle \u00e0 long col comprennent les vannes d&#039;arr\u00eat d&#039;urgence cryog\u00e9niques, les vannes \u00e0 bille cryog\u00e9niques, les vannes \u00e0 globe cryog\u00e9niques, les clapets anti-retour cryog\u00e9niques, les vannes cryog\u00e9niques sp\u00e9ciales GNL, les vannes cryog\u00e9niques sp\u00e9ciales GN, etc. Elles sont principalement utilis\u00e9es dans 300 000 tonnes d&#039;\u00e9thyl\u00e8ne, liqu\u00e9fi\u00e9. le gaz naturel et d&#039;autres appareils chimiques. Les fluides cryog\u00e9niques liquides en sortie, tels que l&#039;\u00e9thyl\u00e8ne, l&#039;oxyg\u00e8ne liquide, l&#039;hydrog\u00e8ne liquide, le gaz naturel liqu\u00e9fi\u00e9, les produits p\u00e9troliers liqu\u00e9fi\u00e9s, etc., sont non seulement inflammables et explosifs, mais \u00e9galement gaz\u00e9ifiables lorsqu&#039;ils chauffent. Lorsqu&#039;ils sont gaz\u00e9ifi\u00e9s, le volume augmente des centaines de fois.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Les raisons pour lesquelles les robinets \u00e0 tournant sph\u00e9rique cryog\u00e9nique n\u00e9cessitent un chapeau \u00e0 long col<\/h2>\n\n\n\n<p>(1) Le couvercle \u00e0 col long a pour fonction de prot\u00e9ger la bo\u00eete \u00e0 garniture de la vanne cryog\u00e9nique, car l&#039;\u00e9tanch\u00e9it\u00e9 de la bo\u00eete \u00e0 garniture est l&#039;une des cl\u00e9s de la vanne cryog\u00e9nique. Si la bo\u00eete d&#039;emballage fuit, cela r\u00e9duira l&#039;effet de refroidissement et entra\u00eenera une gaz\u00e9ification du gaz liqu\u00e9fi\u00e9. \u00c0 basse temp\u00e9rature, avec la diminution de la temp\u00e9rature, l&#039;\u00e9lasticit\u00e9 de la charge dispara\u00eet progressivement et les performances d&#039;\u00e9tanch\u00e9it\u00e9 diminuent. En raison d&#039;une fuite de fluide, le remplissage se forme et la tige de valve g\u00e8le. Cela affecte le fonctionnement normal de la tige de vanne et provoque \u00e9galement de graves fuites dues aux rayures du remplisseur de lisier provoqu\u00e9es par le mouvement de haut en bas de la tige de vanne. Il faut donc veiller \u00e0 ce que la temp\u00e9rature de la charge soit sup\u00e9rieure \u00e0 8 C.<\/p>\n\n\n\n<p>(2) La structure du couvercle de vanne \u00e0 long col est pratique pour enrouler un mat\u00e9riau d&#039;isolation contre le froid afin d&#039;\u00e9viter la perte d&#039;\u00e9nergie froide des vannes cryog\u00e9niques.<\/p>\n\n\n\n<p>(3) La structure \u00e0 long col de la vanne cryog\u00e9nique est pratique pour le remplacement rapide des pi\u00e8ces principales de la vanne en retirant le couvercle de la vanne. \u00c9tant donn\u00e9 que les tuyaux de proc\u00e9d\u00e9 et les vannes de la section froide de l&#039;\u00e9quipement sont souvent install\u00e9s dans la \u00ab bo\u00eete froide \u00bb, le couvercle de vanne \u00e0 long col peut s&#039;\u00e9tendre \u00e0 travers la paroi de la \u00ab bo\u00eete froide \u00bb. Lorsque vous remplacez les pi\u00e8ces principales de la vanne, seul le couvercle de la vanne doit \u00eatre retir\u00e9, mais il n&#039;est pas n\u00e9cessaire de retirer le corps de la vanne. Le corps de la vanne et la canalisation sont soud\u00e9s ensemble pour minimiser les fuites de la bo\u00eete froide et assurer l&#039;\u00e9tanch\u00e9it\u00e9 du&nbsp;<strong><a href=\"https:\/\/zecovalve.com\/fr\/produit\/cryogenic-ball-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\">robinet \u00e0 tournant sph\u00e9rique cryog\u00e9nique<\/mark><\/a><\/strong>.<\/p>\n\n\n\n<p>ZECO Valve est l\u2019un des fabricants de robinets \u00e0 tournant sph\u00e9rique cryog\u00e9niques les plus professionnels. <\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Balises associ\u00e9es :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/\">Soupape ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">Qu'est-ce qu'un robinet-vanne ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/advantages-and-disadvantages-of-globe-valves.html\/\">Qu'est-ce qu'un robinet \u00e0 soupape ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/produit\/manual-gate-valve\/\">Fabricant de robinets-vannes \u00e0 commande manuelle<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diff\u00e9rence entre la vanne \u00e0 vanne et la vanne papillon<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/the-difference-between-globe-valve-and-ball-valve.html\/\">Robinet \u00e0 soupape et robinet \u00e0 bille<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/tag\/shanghai-pressure-reducing-valve-factory\/\">Usine de soupapes de r\u00e9duction de pression de Shanghai<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Qu&#039;est-ce qu&#039;une vanne cryog\u00e9nique ? Les vannes cryog\u00e9niques sont les vannes qui peuvent \u00eatre utilis\u00e9es \u00e0 basse temp\u00e9rature, g\u00e9n\u00e9ralement les vannes seront\u2026 <a title=\"Raisons pour lesquelles un couvercle \u00e0 col long est utilis\u00e9 dans les robinets \u00e0 tournant sph\u00e9rique cryog\u00e9niques\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/fr\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\" aria-label=\"Plus sur Raisons d&#039;utiliser un couvercle \u00e0 col long dans les robinets \u00e0 tournant sph\u00e9rique cryog\u00e9niques\">Lire plus<\/a><\/p>","protected":false},"author":2,"featured_media":19492,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2807,2059,2808,2352,3057],"class_list":["post-16064","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-ball-valve-cover","tag-cryogenic-ball-valve","tag-cryogenic-ball-valves","tag-cryogenic-valve","tag-cryogenic-valve-market","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-1024x1024.jpg",1024,1024,true],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/fr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2807,"name":"ball valve cover","slug":"ball-valve-cover","term_group":0,"term_taxonomy_id":2807,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2059,"name":"Cryogenic Ball Valve","slug":"cryogenic-ball-valve","term_group":0,"term_taxonomy_id":2059,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw"},{"term_id":2808,"name":"cryogenic ball valves","slug":"cryogenic-ball-valves","term_group":0,"term_taxonomy_id":2808,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":2352,"name":"cryogenic valve","slug":"cryogenic-valve","term_group":0,"term_taxonomy_id":2352,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw"},{"term_id":3057,"name":"Cryogenic Valve Market","slug":"cryogenic-valve-market","term_group":0,"term_taxonomy_id":3057,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_40f5bf-86\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET CRYOGENIC VALVE INFORMATION<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCryogenic valves are designed to be utilized in air separation, chemical, or liquified natural gas (LNG) plants. They open in high-pressure conditions and allow the free flow of the gases until the pressure reduces. They assist in reducing the heat that enters the valve from outside, thereby keeping the packing gland temperature above 0 degrees Celsius and avoiding the stem and parts above the bonnet from freezing or frosting. At present, they are widely available in a variety of shapes and sizes to function under different pressure ranges.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cryogenic Valve Market - Snapshot<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe cryogenic Valve Market is likely to witness a healthy CAGR of 4.8% during the forecast period. Increasing trade of LNG has led to the high demand for storage and transportation of cryogenic gases, which in turn is driving the demand for cryogenic valves. Further, the high demand for industrial gases is acting as a catalyst for the growth of cryogenic valves.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:table {\"className\":\"is-style-stripes\"} -->\r\n<figure class=\"wp-block-table is-style-stripes\">\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td>Growth<\/td>\r\n<td>4.8% for the next five years<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Major End-User Type<\/td>\r\n<td>Energy &amp; power<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Major Type<\/td>\r\n<td>Ball valve<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Dominant\u00a0 Application Type<\/td>\r\n<td>Transfer lines<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Region with the highest demand<\/td>\r\n<td>Asia-Pacific<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Key Players<\/td>\r\n<td>Cryocomp,\r\nThe Emerson Electric Company,\r\nThe Flowserve Corporation,\r\nLarsen &amp; Toubro Limited,\r\nPowell Valves,\r\nSchlumberger Limited,\r\nWeir Group.<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>\r\n<!-- \/wp:table -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-cryogenic-valve-market-share-by-application\">Cryogenic Valve Market Share: By Application<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Tanks &amp; Cold Boxes<\/li>\r\n \t<li>Liquefiers<\/li>\r\n \t<li>Transfer lines<\/li>\r\n \t<li>Manifolds &amp; Gas Trains<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cryogenic Valve Market Share: By Type<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Globe Valve<\/li>\r\n \t<li>Gate Valve<\/li>\r\n \t<li>Check Valve<\/li>\r\n \t<li>Ball Valve<\/li>\r\n \t<li>Others<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cryogenic Valve Market Share: By Gas<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>LNG<\/li>\r\n \t<li>Oxygen<\/li>\r\n \t<li>Nitrogen<\/li>\r\n \t<li>Others<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cryogenic Valve Market Share: By End-User<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Energy &amp; Power<\/li>\r\n \t<li>Chemicals<\/li>\r\n \t<li>Food &amp; Beverage<\/li>\r\n \t<li>Healthcare<\/li>\r\n \t<li>Others<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cryogenic Valve Market Share: By Region<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>North America<\/li>\r\n \t<li>Europe<\/li>\r\n \t<li>Asia Pacific<\/li>\r\n \t<li>Middle East &amp; Africa<\/li>\r\n \t<li>South America<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->","parent":0,"count":7,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2807,"label":"ball valve cover"},{"value":2059,"label":"Cryogenic Ball Valve"},{"value":2808,"label":"cryogenic ball valves"},{"value":2352,"label":"cryogenic valve"},{"value":3057,"label":"Cryogenic Valve Market"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Long Neck Cover Used in Cryogenic Ball Valve - Cryogenic Valve | ZECO<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/fr\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Long Neck Cover Used in Cryogenic Ball Valve - Cryogenic Valve | ZECO\" \/>\n<meta property=\"og:description\" content=\"What is a Cryogenic Valve? Cryogenic Valves are the valves that could be used in low temperature condition, usually the valves will ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/fr\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-18T13:36:55+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-09-16T02:29:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"2560\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Cryogenic-Ball-Valve-1-scaled.jpg\",\"width\":2560,\"height\":2560},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\",\"name\":\"Long Neck Cover Used in Cryogenic Ball Valve - Cryogenic Valve | ZECO\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html#primaryimage\"},\"datePublished\":\"2022-06-18T13:36:55+00:00\",\"dateModified\":\"2022-09-16T02:29:20+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\",\"url\":\"https:\/\/zecovalve.com\/reasons-for-long-neck-cover-used-in-cryogenic-ball-valve.html\",\"name\":\"Reasons for Long Neck Cover Used in Cryogenic Ball Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/16064","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/comments?post=16064"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/16064\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media\/19492"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media?parent=16064"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/categories?post=16064"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/tags?post=16064"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}