{"id":16325,"date":"2022-06-20T14:37:38","date_gmt":"2022-06-20T14:37:38","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16325"},"modified":"2022-06-20T14:38:30","modified_gmt":"2022-06-20T14:38:30","slug":"is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/fr\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html","title":{"rendered":"Le robinet \u00e0 soupape est-il dot\u00e9 d&#039;ouvertures d&#039;entr\u00e9e faibles et de sorties \u00e9lev\u00e9es ou d&#039;ouvertures d&#039;entr\u00e9e \u00e9lev\u00e9es et de sorties basses ?"},"content":{"rendered":"<h2 class=\"wp-block-heading\">Pourquoi le robinet \u00e0 soupape est-il con\u00e7u pour avoir des ouvertures d&#039;entr\u00e9e faibles et des ouvertures de sortie \u00e9lev\u00e9es\u00a0?<\/h2>\n\n\n\n<p>Le but est de r\u00e9duire la r\u00e9sistance \u00e0 l&#039;\u00e9coulement et d&#039;\u00e9conomiser des efforts lors de l&#039;ouverture de la vanne. Dans le m\u00eame temps, lorsque la vanne est ferm\u00e9e, le joint entre le bo\u00eetier de vanne et le chapeau et la garniture autour de la tige de vanne ne sont pas soumis \u00e0 des contraintes et ne seront pas expos\u00e9s aux effets de la pression et de la temp\u00e9rature moyennes pendant une longue p\u00e9riode, ce qui peut prolonger la dur\u00e9e de vie et r\u00e9duire la probabilit\u00e9 de fuite. De plus, la garniture peut \u00eatre remplac\u00e9e ou ajout\u00e9e lorsque la vanne est ferm\u00e9e pour un entretien facile.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"300\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/3f370c4a5808283dd0d9ed1ee0a58195.png\" alt=\"\" class=\"wp-image-16326\" title=\"\/uploads\/image\/2020\/02\/28\/3f370c4a5808283dd0d9ed1ee0a58195.png\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/3f370c4a5808283dd0d9ed1ee0a58195.png 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/3f370c4a5808283dd0d9ed1ee0a58195-300x225.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<p>Beaucoup de gens pensent que tous les robinets \u00e0 soupape ont des ouvertures d&#039;entr\u00e9e faibles et des ouvertures de sortie \u00e9lev\u00e9es, mais ce n&#039;est pas vrai. Parfois l&nbsp;<a href=\"https:\/\/zecovalve.com\/fr\/products\/globe-valve-check-valve\/\">robinet \u00e0 soupape<\/a>&nbsp;est r\u00e9gl\u00e9 avec des ouvertures d\u2019entr\u00e9e \u00e9lev\u00e9es et des ouvertures de sortie basses.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>1. le robinet \u00e0 soupape haute pression d&#039;un diam\u00e8tre sup\u00e9rieur \u00e0 100 mm<\/strong><\/h3>\n\n\n\n<p>En raison des mauvaises performances d&#039;\u00e9tanch\u00e9it\u00e9 des vannes de grand diam\u00e8tre, dans cette m\u00e9thode, lorsque le robinet \u00e0 soupape est ferm\u00e9, la pression moyenne agit sur le clapet de la vanne pour augmenter l&#039;\u00e9tanch\u00e9it\u00e9 de la vanne.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>2. Lorsque deux vannes \u00e0 soupape sont connect\u00e9es en s\u00e9rie sur la canalisation de d\u00e9rivation, la seconde n\u00e9cessite une \u00ab entr\u00e9e haute et une sortie basse \u00bb<\/strong><\/h3>\n\n\n\n<p>Afin d&#039;assurer l&#039;\u00e9tanch\u00e9it\u00e9 de la vanne lors d&#039;un cycle de maintenance, la vanne souvent ouverte et ferm\u00e9e n\u00e9cessite deux vannes \u00e0 soupape connect\u00e9es en s\u00e9rie. Pour le syst\u00e8me bypass, l&#039;installation de ce bypass a les fonctions suivantes :<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>\u2460 \u00c9quilibrez la pression avant et arri\u00e8re de la vanne principale du pipeline, facilitez son ouverture et \u00e9conomisez des efforts, et r\u00e9duisez l&#039;usure de la vanne principale du pipeline\u00a0;<\/li><li>\u2461 Tuyau chaud \u00e0 petit d\u00e9bit pendant le d\u00e9marrage\u00a0;<\/li><li>\u2462 Sur la canalisation d&#039;eau d&#039;alimentation principale, contr\u00f4lez le d\u00e9bit d&#039;eau d&#039;alimentation et contr\u00f4lez la vitesse de suralimentation de la chaudi\u00e8re pour effectuer le test de pression hydraulique de la chaudi\u00e8re. Selon le sens d&#039;\u00e9coulement du fluide, la vanne d&#039;arr\u00eat de d\u00e9rivation est une vanne primaire et une vanne secondaire. La vanne primaire et la vanne secondaire sont ferm\u00e9es pendant le fonctionnement normal de l&#039;unit\u00e9 et toutes deux sont en contact direct avec le fluide. Afin d&#039;\u00e9viter que le joint entre le bo\u00eetier de vanne secondaire et le chapeau et la garniture autour de la tige de vanne ne soient affect\u00e9s par le fluide et la temp\u00e9rature pendant une longue p\u00e9riode, et que la garniture de la vanne puisse \u00eatre remplac\u00e9e pendant le fonctionnement, le sens d&#039;installation requis pour le la vanne secondaire est \u00ab\u00a0entr\u00e9e haute et sortie basse\u00a0\u00bb.<\/li><\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>3. \u00c9vacuez la chaudi\u00e8re et purgez le robinet \u00e0 soupape.<\/strong><\/h3>\n\n\n\n<p>L&#039;\u00e9vacuation de la chaudi\u00e8re et la ventilation des vannes \u00e0 soupape ne sont utilis\u00e9es que dans le processus de d\u00e9marrage et d&#039;alimentation de la chaudi\u00e8re. La fr\u00e9quence d&#039;ouverture et de fermeture est faible, mais le fluide de travail est souvent perdu en raison d&#039;un joint peu \u00e9tanche. Pour cette raison, afin d&#039;am\u00e9liorer l&#039;\u00e9tanch\u00e9it\u00e9 de certaines centrales \u00e9lectriques, le sens d&#039;installation de ces vannes d&#039;arr\u00eat est \u00ab entr\u00e9e haute et sortie basse \u00bb.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>4. Valve \u00e9lectromagn\u00e9tique \u00e0 d\u00e9gagement rapide<\/strong><\/h3>\n\n\n\n<p>La fonction de la vanne \u00e9lectromagn\u00e9tique d&#039;arr\u00eat rapide est de se fermer rapidement et de couper rapidement l&#039;alimentation en carburant. La structure de la vanne \u00e9lectromagn\u00e9tique \u00e0 d\u00e9gagement rapide est similaire \u00e0 celle de la vanne d&#039;arr\u00eat. Si la soupape \u00e9lectromagn\u00e9tique \u00e0 d\u00e9gagement rapide entre \u00e9galement dans le fluide de travail par la partie inf\u00e9rieure et s&#039;\u00e9coule par la partie sup\u00e9rieure, la force du carburant agissant sur la partie inf\u00e9rieure du volet de la soupape \u00e9lectromagn\u00e9tique \u00e0 d\u00e9gagement rapide est tr\u00e8s importante et le poids de la valve \u00e9lectromagn\u00e9tique \u00e0 d\u00e9gagement rapide est beaucoup plus petite qu&#039;elle. Par cons\u00e9quent, si le fluide de travail p\u00e9n\u00e8tre dans la vanne \u00e0 d\u00e9connexion rapide par la partie inf\u00e9rieure, le couple g\u00e9n\u00e9r\u00e9 par le poids est inf\u00e9rieur au couple g\u00e9n\u00e9r\u00e9 par la pression du carburant, et le carburant ne peut pas \u00eatre coup\u00e9 lorsque la vanne \u00e0 d\u00e9connexion rapide fonctionne, ainsi ne parvenant pas \u00e0 atteindre le but vis\u00e9. Si le fluide de travail entre par la partie sup\u00e9rieure de la vanne \u00e0 d\u00e9connexion rapide, une fois la vanne \u00e0 d\u00e9connexion rapide actionn\u00e9e, la pression derri\u00e8re la vanne est rapidement r\u00e9duite et la force du carburant agissant sur la partie inf\u00e9rieure du disque est rapidement r\u00e9duite. r\u00e9duit \u00e0 z\u00e9ro.<\/p>\n\n\n\n<p>G\u00e9n\u00e9ralement, il est difficile de fermer la vanne lorsque les ouvertures d&#039;entr\u00e9e et de sortie sont basses et hautes, sous un grand diam\u00e8tre et une haute pression. Si l&#039;entr\u00e9e basse et la sortie haute sont utilis\u00e9es dans des conditions de haute pression et de gros calibre, la tige de valve se d\u00e9forme facilement et se plie sous la pression de l&#039;eau pendant une longue p\u00e9riode, ce qui affecte la s\u00e9curit\u00e9 et l&#039;\u00e9tanch\u00e9it\u00e9 de la valve. L&#039;utilisation d&#039;un r\u00e9glage d&#039;ouvertures d&#039;entr\u00e9e et de sortie faibles peut r\u00e9duire le diam\u00e8tre de la tige de vanne, ce qui permet \u00e9galement de r\u00e9duire les co\u00fbts pour les fabricants et les utilisateurs.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Balises associ\u00e9es :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/\">Soupape ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/introduction-of-epdm-nbr-butterfly-valve-seat-industrial-valve-information-news-zeco-valve.html\/\">Robinet \u00e0 papillon NBR<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/tag\/shanghai-pressure-reducing-valve-factory\/\">Usine de soupapes de r\u00e9duction de pression de Shanghai<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">Qu'est-ce qu'un robinet-vanne ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diff\u00e9rence entre la vanne \u00e0 vanne et la vanne papillon<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-axial-flow-silent-check-valve.html\/\">Qu'est-ce qu'un clapet anti-retour axial ?<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valves-and-ball-valves.html\/\">Vanne et robinet \u00e0 boisseau sph\u00e9rique<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/produit\/manual-gate-valve\/\">Fabricant de robinets-vannes \u00e0 commande manuelle<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/the-function-of-globe-valve-in-pipeline-system.html\/\">Que sont les vannes \u00e0 soupape\u00a0?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/advantages-and-disadvantages-of-globe-valves.html\/\">Qu'est-ce qu'un robinet \u00e0 soupape ?<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Pourquoi le robinet \u00e0 soupape est-il con\u00e7u pour avoir des ouvertures d&#039;entr\u00e9e faibles et des ouvertures de sortie \u00e9lev\u00e9es\u00a0? Le but est de faire circuler\u2026 <a title=\"Le robinet \u00e0 soupape est-il dot\u00e9 d&#039;ouvertures d&#039;entr\u00e9e faibles et de sorties \u00e9lev\u00e9es ou d&#039;ouvertures d&#039;entr\u00e9e \u00e9lev\u00e9es et de sorties basses ?\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/fr\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\" aria-label=\"Plus sur Est-ce le robinet \u00e0 soupape avec des ouvertures d&#039;entr\u00e9e basses et des ouvertures de sortie hautes ou des ouvertures d&#039;entr\u00e9e hautes et de sortie basses\">Lire plus<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1929],"tags":[1805,2202,2203],"class_list":["post-16325","post","type-post","status-publish","format-standard","hentry","category-globe-valve","tag-globe-valve","tag-high-pressure-globe-valve","tag-quick-release-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/fr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1929,"name":"Globe Valve","slug":"globe-valve","term_group":0,"term_taxonomy_id":1929,"taxonomy":"category","description":"","parent":0,"count":21,"filter":"raw","cat_ID":1929,"category_count":21,"category_description":"","cat_name":"Globe Valve","category_nicename":"globe-valve","category_parent":0}],"tag_info":[{"term_id":1805,"name":"globe valve","slug":"globe-valve","term_group":0,"term_taxonomy_id":1805,"taxonomy":"post_tag","description":"","parent":0,"count":21,"filter":"raw"},{"term_id":2202,"name":"high-pressure globe valve","slug":"high-pressure-globe-valve","term_group":0,"term_taxonomy_id":2202,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2203,"name":"quick-release valve","slug":"quick-release-valve","term_group":0,"term_taxonomy_id":2203,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1929,"label":"Globe Valve"}],"post_tag":[{"value":1805,"label":"globe valve"},{"value":2202,"label":"high-pressure globe valve"},{"value":2203,"label":"quick-release valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Is the globe valve with low inlet and high outlet openings or high inlet and low outlet openings - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/fr\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Is the globe valve with low inlet and high outlet openings or high inlet and low outlet openings - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Why is the globe valve designed to be with low inlet and high outlet openings? The purpose is to make the flow ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/fr\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-20T14:37:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-20T14:38:30+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/3f370c4a5808283dd0d9ed1ee0a58195.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\">\n\t<meta name=\"twitter:data2\" content=\"3 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/3f370c4a5808283dd0d9ed1ee0a58195.png\",\"width\":400,\"height\":300},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\",\"name\":\"Is the globe valve with low inlet and high outlet openings or high inlet and low outlet openings - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html#primaryimage\"},\"datePublished\":\"2022-06-20T14:37:38+00:00\",\"dateModified\":\"2022-06-20T14:38:30+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\",\"url\":\"https:\/\/zecovalve.com\/is-the-globe-valve-with-low-inlet-and-high-outlet-openings-or-high-inlet-and-low-outlet-openings.html\",\"name\":\"Is the globe valve with low inlet and high outlet openings or high inlet and low outlet openings\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/16325","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/comments?post=16325"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/16325\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media?parent=16325"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/categories?post=16325"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/tags?post=16325"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}