{"id":16330,"date":"2022-06-20T14:41:24","date_gmt":"2022-06-20T14:41:24","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16330"},"modified":"2022-08-16T13:06:10","modified_gmt":"2022-08-16T13:06:10","slug":"repair-and-maintenance-of-electric-ball-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/fr\/repair-and-maintenance-of-electric-ball-valve.html","title":{"rendered":"R\u00e9paration et entretien du robinet \u00e0 boisseau sph\u00e9rique \u00e9lectrique"},"content":{"rendered":"<h2 class=\"wp-block-heading\">1. Les robinets \u00e0 tournant sph\u00e9rique \u00e9lectriques doivent \u00eatre stock\u00e9s dans des pi\u00e8ces s\u00e8ches et ventil\u00e9es, et les deux extr\u00e9mit\u00e9s du passage doivent \u00eatre bloqu\u00e9es.<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">2. Les robinets \u00e0 tournant sph\u00e9rique \u00e9lectriques stock\u00e9s pendant une longue p\u00e9riode doivent \u00eatre inspect\u00e9s r\u00e9guli\u00e8rement pour \u00e9liminer la salet\u00e9 et recouverts d&#039;huile antirouille.<\/h2>\n\n\n\n<h2 class=\"wp-block-heading\">3. Le&nbsp;<a href=\"https:\/\/zecovalve.com\/fr\/products\/electric-ball-valve.html\/\" target=\"_blank\" rel=\"noreferrer noopener\">robinet \u00e0 boisseau sph\u00e9rique \u00e0 commande \u00e9lectrique<\/a>&nbsp;doit \u00eatre inspect\u00e9 r\u00e9guli\u00e8rement apr\u00e8s l\u2019installation. Les principaux \u00e9l\u00e9ments de contr\u00f4le sont les suivants :<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>(1) \u00c9tat d\u2019usure de la surface d\u2019\u00e9tanch\u00e9it\u00e9.<\/li><li>(2) Usure du filetage trap\u00e9zo\u00efdal de la tige et de l&#039;\u00e9crou de tige.<\/li><li>(3) Que le remplissage soit obsol\u00e8te ou non et s&#039;il est endommag\u00e9, il doit \u00eatre remplac\u00e9 \u00e0 temps.<\/li><li>(4) Apr\u00e8s la r\u00e9paration et l&#039;assemblage des vannes \u00e9lectriques, le test de performance d&#039;\u00e9tanch\u00e9it\u00e9 doit \u00eatre effectu\u00e9.<\/li><\/ul>\n\n\n\n<p>Au cours de l&#039;exploitation, toutes sortes de raccords de vannes du\u00a0<a href=\"https:\/\/zecovalve.com\/fr\/products\/electric-ball-valve.html\/\" target=\"_blank\" rel=\"noreferrer noopener\">robinet \u00e0 tournant sph\u00e9rique \u00e0 commande \u00e9lectrique<\/a>\u00a0doit \u00eatre complet et intact. Les boulons sur les brides et les supports sont indispensables. Les fils doivent \u00eatre intacts et intacts. Aucun rel\u00e2chement n&#039;est autoris\u00e9. Les \u00e9crous de fixation du volant doivent \u00eatre serr\u00e9s \u00e0 temps en cas de desserrage, afin de ne pas user la connexion ou de perdre le volant et la plaque signal\u00e9tique. Si le volant est perdu, il ne peut pas \u00eatre remplac\u00e9 par une cl\u00e9 dynamom\u00e9trique. Cela devrait \u00eatre assorti dans le temps. Le presse-\u00e9toupe ne doit pas \u00eatre de travers ni sans jeu de pr\u00e9-serrage. Pour les vannes \u00e9lectriques qui sont facilement contamin\u00e9es par la pluie, la neige, la poussi\u00e8re et autres salet\u00e9s, la tige de vanne doit \u00eatre \u00e9quip\u00e9e d&#039;un couvercle de protection. Le dirigeant sur le\u00a0<a href=\"https:\/\/zecovalve.com\/fr\/products\/electric-ball-valve.html\/\" target=\"_blank\" rel=\"noreferrer noopener\">robinet \u00e0 tournant sph\u00e9rique \u00e9lectrique<\/a>\u00a0doit \u00eatre complet, pr\u00e9cis et clair. Les joints en plomb, les capuchons et les accessoires pneumatiques des vannes \u00e9lectriques doivent \u00eatre en bon \u00e9tat. La gaine d\u2019isolation thermique doit \u00eatre exempte de d\u00e9pressions et de fissures. Il est interdit de cogner, de se tenir debout ou de soutenir des objets lourds sur les vannes \u00e0 bille \u00e9lectriques en fonctionnement, en particulier les vannes \u00e0 bille \u00e9lectriques non m\u00e9talliques et en fonte.\u00a0<strong>robinets \u00e0 boisseau sph\u00e9rique \u00e9lectriques<\/strong>.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Balises associ\u00e9es :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/\">Soupape ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valves-and-ball-valves.html\/\">Vanne et robinet \u00e0 boisseau sph\u00e9rique<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/gate-valve-problems.html\/\">R\u00e9paration de vannes \u00e0 vanne<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/advantages-and-disadvantages-of-globe-valves.html\/\">Qu'est-ce qu'un robinet \u00e0 soupape ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-axial-flow-silent-check-valve.html\/\">Qu'est-ce qu'un clapet anti-retour axial ?<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/produit\/manual-gate-valve\/\">Fabricant de robinets-vannes \u00e0 commande manuelle<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/the-function-of-globe-valve-in-pipeline-system.html\/\">Que sont les vannes \u00e0 soupape\u00a0?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diff\u00e9rence entre la vanne \u00e0 vanne et la vanne papillon<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">Qu'est-ce qu'un robinet-vanne ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/tag\/shanghai-pressure-reducing-valve-factory\/\">Usine de soupapes de r\u00e9duction de pression de Shanghai<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1. Les robinets \u00e0 boisseau sph\u00e9rique \u00e9lectriques doivent \u00eatre stock\u00e9s dans des locaux secs et ventil\u00e9s, et les deux extr\u00e9mit\u00e9s du passage doivent \u00eatre bloqu\u00e9es. 2. ... <a title=\"R\u00e9paration et entretien du robinet \u00e0 boisseau sph\u00e9rique \u00e9lectrique\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/fr\/repair-and-maintenance-of-electric-ball-valve.html\" aria-label=\"Plus sur R\u00e9paration et Entretien de Robinet \u00e0 Bille \u00c9lectrique\">Lire plus<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1927],"tags":[1828,2204,2205,2173,2060,1841],"class_list":["post-16330","post","type-post","status-publish","format-standard","hentry","category-ball-valve","tag-ball-valve-on-off-position","tag-ball-valves","tag-electric-actuated-ball-valve","tag-electric-ball-valve","tag-electric-ball-valves","tag-how-to-open-a-stuck-ball-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/fr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1927,"name":"Ball Valve","slug":"ball-valve","term_group":0,"term_taxonomy_id":1927,"taxonomy":"category","description":"Ball Valve Description","parent":0,"count":82,"filter":"raw","cat_ID":1927,"category_count":82,"category_description":"Ball Valve Description","cat_name":"Ball Valve","category_nicename":"ball-valve","category_parent":0}],"tag_info":[{"term_id":1828,"name":"Ball Valve On Off Position","slug":"ball-valve-on-off-position","term_group":0,"term_taxonomy_id":1828,"taxonomy":"post_tag","description":"<!-- wp:paragraph -->\r\n\r\nBall valves, also known as quarter-turn valves, are used for water, oil, and gas. They have a handle that operates a concealed ball with a hole through the middle. As the name implies, you give this valve a quarter turn to fully open it or close it.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"https:\/\/zecovalve.com\/contact\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET BALL VALVE ON OFF POSITION INFORMATION<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-ball-valve-on-off-position\">Ball Valve On Off Position<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nOpen or closed: When the handle of a ball valve is parallel to the valve or pipe, it\u2019s open. When it\u2019s perpendicular, it\u2019s closed. This makes it easy to know if a ball valve is open or closed, just by looking at it. The ball valve below is in the open position.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nBall valves are adeptly named because of the ball that sits inside the housing unit. The ball has a hole through the center. This hole faces the flow of water when the valve is open. When the valve is closed, the solid side of the ball faces the flow, effectively blocking the further forward movement of the liquid. Because of this design, ball valves are a type of shut-off valve, meaning they can only be used to stop and start flow; not regulate the flow.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nBall valves are perhaps the easiest valve to see if they are open or closed. If the handle on top is parallel to the valve, it's open. Likewise, if the handle is perpendicular to the top, the valve is closed.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCommon places you might find a ball valve are in irrigation and in sites where you need to control water supply from one area to another.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:image {\"align\":\"center\",\"id\":26650,\"sizeSlug\":\"full\",\"linkDestination\":\"none\"} -->\r\n<figure class=\"wp-block-image aligncenter size-full\"><img class=\"wp-image-26650\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/open-and-closed-ball-valve.png\" alt=\"\" \/><\/figure>\r\n<!-- \/wp:image -->","parent":0,"count":9,"filter":"raw"},{"term_id":2204,"name":"Ball Valves","slug":"ball-valves","term_group":0,"term_taxonomy_id":2204,"taxonomy":"post_tag","description":"","parent":0,"count":38,"filter":"raw"},{"term_id":2205,"name":"electric actuated ball valve","slug":"electric-actuated-ball-valve","term_group":0,"term_taxonomy_id":2205,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2173,"name":"Electric ball valve","slug":"electric-ball-valve","term_group":0,"term_taxonomy_id":2173,"taxonomy":"post_tag","description":"","parent":0,"count":11,"filter":"raw"},{"term_id":2060,"name":"electric ball valves","slug":"electric-ball-valves","term_group":0,"term_taxonomy_id":2060,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":1841,"name":"How to Open a Stuck Ball Valve","slug":"how-to-open-a-stuck-ball-valve","term_group":0,"term_taxonomy_id":1841,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_5caaaa-64\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"https:\/\/zecovalve.com\/contact\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>HOW TO OPEN A STUCK BALL VALVE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-what-causes-stuck-ball-valve\">What Causes Stuck <strong><mark class=\"has-inline-color has-contrast-2-color\" style=\"background-color: var(--base)\"><a href=\"https:\/\/zecovalve.com\/product-category\/ball-valve\" target=\"_blank\" rel=\"noreferrer noopener\">Ball Valve<\/a><\/mark><\/strong>?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nOne of the most common types of ball valve failures involves a buildup of dirt and sediment within the valve, making it difficult to open and close. The use of solvent cement glue can also clog up the ball, causing it to stick to the inside of the valve and resist turning. If this happens, you\u2019ll want to take the valve apart and clean out any grime you see.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nAnother frequent ball valve failure occurs when the elastic used to seal the valve (often in the form of an O-ring) gets worn down over time due to liquid or gas getting pushed through it. Since this is a natural symptom of use, you\u2019ll want to swap out the elastic when you notice cracks or leakage. Turning down the intensity of liquid flowing through the valve can also help extend the lifespan of the O-ring.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nAs the elastic starts to go, so too does the inner packing of the valve stem. Any scratching or damage to the valve stem requires someone to either replace the stem or the whole valve before the whole thing falls apart.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nMake sure to look for leak points at the nuts holding the bolts in as well. This indicates that the nuts are too loose or that the end connector needs realignment. Damage to O-rings around the nuts can also prove a culprit of these leaks.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>How to Open A Stuck Ball Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nBall valves are commonly used valves for main water and various branch shutoffs. This valve functions as an ON\/OFF valve which means that the valve should be either completely open allowing full flow, or completely closed, stopping the entire water flow. Occasionally, it may be necessary to loosen a ball valve because it is stuck or tight, thereby creating an obstruction to fluid flow. If a ball valve won\u2019t open, perform the following steps to rectify the issue:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list {\"ordered\":true} -->\r\n<ol>\r\n \t<li>Manual operation<\/li>\r\n \t<li>Turn off the main water supply.<\/li>\r\n \t<li>Then, loosen the valve by opening and closing it multiple times by turning its handle.<\/li>\r\n \t<li>Gently hammer the valve body multiple times on the valve body to break and free up the particles that are trapped between the ball and the valve body.<\/li>\r\n \t<li>Gently wiggle and rock the valve handle to help service the ball element and force it to move. Also, try to remove the valve handle and turn the valve a few times using a plier to help it move freely, and place the handle back on the valve using its screw. If these steps don\u2019t work, move on to step 2.<\/li>\r\n<\/ol>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:block {\"ref\":15781} \/-->\r\n\r\n<!-- wp:block {\"ref\":15788} \/-->\r\n\r\n<!-- wp:block {\"ref\":20648} \/-->\r\n\r\n<!-- wp:block {\"ref\":20644} \/-->\r\n\r\n<!-- wp:block {\"ref\":20646} \/-->\r\n\r\n<!-- wp:block {\"ref\":20641} \/-->\r\n\r\n<!-- wp:block {\"ref\":16760} \/-->\r\n\r\n<!-- wp:block {\"ref\":16233} \/-->\r\n\r\n<!-- wp:block {\"ref\":15809} \/-->\r\n\r\n<!-- wp:block {\"ref\":15797} \/-->","parent":0,"count":7,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1927,"label":"Ball Valve"}],"post_tag":[{"value":1828,"label":"Ball Valve On Off Position"},{"value":2204,"label":"Ball Valves"},{"value":2205,"label":"electric actuated ball valve"},{"value":2173,"label":"Electric ball valve"},{"value":2060,"label":"electric ball valves"},{"value":1841,"label":"How to Open a Stuck Ball Valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Repair and Maintenance of Electric Ball Valve - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/fr\/repair-and-maintenance-of-electric-ball-valve.html\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Repair and Maintenance of Electric Ball Valve - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"1. Electric ball valves should be stored in dry and ventilated rooms, and both ends of the passage should be blocked. 2. ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/fr\/repair-and-maintenance-of-electric-ball-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-20T14:41:24+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-16T13:06:10+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\">\n\t<meta name=\"twitter:data2\" content=\"1 minute\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html\",\"name\":\"Repair and Maintenance of Electric Ball Valve - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-20T14:41:24+00:00\",\"dateModified\":\"2022-08-16T13:06:10+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html\",\"url\":\"https:\/\/zecovalve.com\/repair-and-maintenance-of-electric-ball-valve.html\",\"name\":\"Repair and Maintenance of Electric Ball Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/16330","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/comments?post=16330"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/16330\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media?parent=16330"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/categories?post=16330"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/tags?post=16330"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}