{"id":2165,"date":"2021-12-28T10:05:18","date_gmt":"2021-12-28T10:05:18","guid":{"rendered":"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html"},"modified":"2022-11-01T02:58:23","modified_gmt":"2022-11-01T02:58:23","slug":"natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/fr\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html","title":{"rendered":"Tour de refroidissement \u00e0 tirage naturel &amp; Tour de refroidissement \u00e0 tirage m\u00e9canique"},"content":{"rendered":"<p>Dans de nombreuses installations industrielles, divers \u00e9quipements ainsi que de nombreux fluides utilis\u00e9s dans les syst\u00e8mes de traitement doivent \u00eatre refroidis. Ce refroidissement se fait majoritairement avec de l&#039;eau. Cependant, \u00e0 mesure que l\u2019eau de refroidissement est utilis\u00e9e, elle absorbe de la chaleur et perd son efficacit\u00e9 de refroidissement. L&#039;eau doit rester fra\u00eeche.<\/p>\n\n\n\n<p>Le rejet d&#039;eau chaude dans des \u00e9tangs ou des bassins peut \u00eatre pr\u00e9judiciable \u00e0 l&#039;environnement. Il est \u00e9galement co\u00fbteux de remplacer l&#039;eau rejet\u00e9e. Le moyen le plus efficace consiste \u00e0 refroidir l\u2019eau chaude et \u00e0 la r\u00e9utiliser.<\/p>\n\n\n\n<p>L\u2019\u00e9quipement le plus couramment utilis\u00e9 \u00e0 cet effet est la tour de refroidissement. Les tours de refroidissement font partie d&#039;un syst\u00e8me d&#039;eau de refroidissement dans une installation commerciale ou industrielle.<\/p>\n\n\n\n\n\n<p>Dans l&#039;\u00e9changeur thermique, la chaleur d&#039;un fluide de proc\u00e9d\u00e9 est transf\u00e9r\u00e9e \u00e0 l&#039;eau de refroidissement. Apr\u00e8s avoir absorb\u00e9 la chaleur du fluide de proc\u00e9d\u00e9, l&#039;eau s&#039;\u00e9coule de l&#039;\u00e9changeur de chaleur vers le sommet de la tour de refroidissement. L\u2019eau tombe ensuite \u00e0 travers la tour et est expos\u00e9e \u00e0 l\u2019air, qui \u00e0 son tour refroidit l\u2019eau. L&#039;eau refroidie est collect\u00e9e au bas de la tour et est pomp\u00e9e \u00e0 travers le syst\u00e8me pour \u00eatre r\u00e9utilis\u00e9e. Les tours de refroidissement refroidissent l\u2019eau en l\u2019exposant \u00e0 l\u2019air, ce qui provoque l\u2019\u00e9vaporation d\u2019une partie de l\u2019eau. L&#039;\u00e9vaporation est un processus dans lequel la chaleur contenue dans l&#039;eau transforme une partie de l&#039;eau en vapeur. Lorsque l\u2019eau se transforme en vapeur, la chaleur est \u00e9vacu\u00e9e, ce qui donne de l\u2019eau refroidie. Dans une tour de refroidissement, la chaleur contenue dans l\u2019eau est \u00e9vacu\u00e9e de la tour sous forme de vapeur \u00e0 mesure que l\u2019eau s\u2019\u00e9vapore.<\/p>\n\n\n\n<p>La conduction et la convection jouent un r\u00f4le important dans une tour de refroidissement. Dans la tour, l\u2019eau entre en contact direct avec l\u2019air. Lorsque cela se produit, une partie de la chaleur de l\u2019eau est transf\u00e9r\u00e9e directement \u00e0 l\u2019air par conduction et convection.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Quels types de vannes de tour de refroidissement existe-t-il ?<\/h2>\n\n\n\n<p>Toutes les tours de refroidissement fonctionnent fondamentalement selon les m\u00eames principes, cependant, leurs conceptions peuvent \u00eatre divis\u00e9es en deux types\u00a0: les tours \u00e0 tirage naturel et les tours \u00e0 tirage m\u00e9canique (tour de refroidissement \u00e0 tirage induit). <\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-what-is-a-natural-draft-cooling-tower\">Qu\u2019est-ce qu\u2019une tour de refroidissement \u00e0 tirage naturel ?<\/h2>\n\n\n\n<p>La tour de refroidissement \u00e0 tirage naturel est un \u00e9changeur de chaleur ouvert \u00e0 contact direct o\u00f9 l&#039;eau chaude du syst\u00e8me ou du condenseur est refroidie par contact direct avec l&#039;air frais. Les tours de refroidissement utilisent le principe de l\u2019\u00e9vaporation de l\u2019eau \u00e0 contre-courant du flux d\u2019air. De l&#039;eau chaude est pulv\u00e9ris\u00e9e par les buses pour augmenter la surface de transfert de chaleur. La temp\u00e9rature et l\u2019humidit\u00e9 de l\u2019air augmentent apr\u00e8s un transfert de chaleur par contact direct entre l\u2019eau chaude et l\u2019air frais. L&#039;air chaud et humide, moins dense, monte au sommet de la tour et l&#039;eau froide est collect\u00e9e au bas de la tour. L&#039;air frais est fourni par le bas de la tour de refroidissement en raison de la diff\u00e9rence de densit\u00e9 entre l&#039;air chaud \u00e0 l&#039;int\u00e9rieur de la chemin\u00e9e et l&#039;air atmosph\u00e9rique \u00e0 l&#039;ext\u00e9rieur de la tour de refroidissement.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principe de la tour de refroidissement \u00e0 tirage naturel<\/h2>\n\n\n\n<p>Le d\u00e9bit d&#039;air est obtenu dans les syst\u00e8mes de tour de refroidissement \u00e0 tirage naturel gr\u00e2ce \u00e0 l&#039;effet chemin\u00e9e de la structure m\u00eame de la tour de refroidissement, qui utilise la diff\u00e9rence de pression naturelle. L&#039;air chaud et humide est moins dense, ce qui le fait sortir de la tour de refroidissement dans l&#039;atmosph\u00e8re et aspirer de l&#039;air frais plus dense. La diff\u00e9rence entre l\u2019air chaud \u00e0 l\u2019int\u00e9rieur de la tour et l\u2019air plus frais \u00e0 l\u2019ext\u00e9rieur cr\u00e9e un flux d\u2019air parfait. Pour qu&#039;un d\u00e9bit d&#039;air suffisant se produise, une formule math\u00e9matique sp\u00e9cifique est utilis\u00e9e pour calculer la hauteur de la tour de refroidissement afin de garantir qu&#039;elle est presque aussi grande que la diff\u00e9rence de densit\u00e9. Cela signifie que les tours de refroidissement utilisant ce syst\u00e8me ont tendance \u00e0 \u00eatre grandes : environ 200 m\u00e8tres de haut et 150 m\u00e8tres de large. Il y a \u00e9galement une quantit\u00e9 importante d\u2019eau qui coule dans les tours. La coque elle-m\u00eame est g\u00e9n\u00e9ralement constitu\u00e9e de b\u00e9ton de forme hyperbolique. La tour de refroidissement \u00e0 tirage naturel est le choix privil\u00e9gi\u00e9 pour les climats frais et humides et pour les fortes charges hivernales.<\/p>\n\n\n\n<p>L&#039;eau chaude qui doit \u00eatre refroidie dans la tour de refroidissement \u00e0 tirage naturel est pomp\u00e9e via l&#039;entr\u00e9e d&#039;eau chaude. L&#039;entr\u00e9e est reli\u00e9e \u00e0 des buses qui pulv\u00e9risent l&#039;eau sur le mat\u00e9riau de remplissage, ce qui offre une grande surface de transfert de chaleur. Au bas de la tour, la structure est ouverte pour aspirer l&#039;air frais, qui circule ensuite vers le haut et permet un transfert de chaleur par contact direct entre l&#039;eau chaude et l&#039;air. L\u2019eau chaude lib\u00e8re de la chaleur apr\u00e8s avoir \u00e9t\u00e9 en contact direct avec l\u2019air frais et une partie de l\u2019eau chaude s\u2019\u00e9vapore. L&#039;eau froide est collect\u00e9e au bas de la tour.<\/p>\n\n\n\n<p>L\u2019air chaud et humide est \u00e9vacu\u00e9 du sommet de la tour dans l\u2019atmosph\u00e8re.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Avantages des tours de refroidissement \u00e0 tirage naturel<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Aucun ventilateur \u00e9lectrique n&#039;est install\u00e9 donc \u00e9conomie d&#039;\u00e9nergie<\/li><li>Aucun probl\u00e8me de corrosion<\/li><li>L&#039;entretien est faible<\/li><li>Aucune recirculation de l&#039;air ne se produit en raison de la sortie haute de la chemin\u00e9e<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Inconv\u00e9nients des tours de refroidissement \u00e0 tirage naturel<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Un \u00e9norme d\u00e9bit d\u2019eau est n\u00e9cessaire.<\/li><li>Ceux-ci n\u00e9cessitent une grande surface.<\/li><li>Sa performance d\u00e9pend de la vitesse et de la direction du vent.<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Qu&#039;est-ce qu&#039;une tour de refroidissement \u00e0 tirage m\u00e9canique\u00a0?<\/h2>\n\n\n\n<p>Les tours de refroidissement \u00e0 tirage induit sont un type de tour \u00e0 tirage m\u00e9canique dot\u00e9e d&#039;un ou plusieurs ventilateurs. Ces ventilateurs seront situ\u00e9s au sommet de la tour, aspirant l&#039;air vers le haut \u00e0 contre-courant du flux d&#039;eau vers le bas. L\u2019eau circule autour de l\u2019emballage ou de la terrasse en bois. Dans ces mod\u00e8les, l&#039;eau la plus froide se trouve au fond, entrant en contact avec l&#039;air le plus sec puisque le d\u00e9bit d&#039;air est \u00e0 contre-courant du d\u00e9bit d&#039;eau.<\/p>\n\n\n\n<p>L\u2019eau la plus chaude se trouvant pr\u00e8s du sommet de la tour \u00e9tant en contact avec l\u2019air humide, il en r\u00e9sulte un transfert de chaleur incroyablement efficace. Les tours induites seront de forme ronde ou carr\u00e9e, distribuant l&#039;eau via un syst\u00e8me d&#039;arrosage ou de branchement statique. L&#039;eau entrante est inject\u00e9e dans toute la tour avec un collecteur de distribution de pulv\u00e9risation. Le jet est dirig\u00e9 vers le bas afin de maximiser le contact de l&#039;eau et de l&#039;air. Ce processus est maximis\u00e9 par le remplissage d&#039;eau de refroidissement, compos\u00e9 de bois, de m\u00e9tal, de PVC ou d&#039;autres mat\u00e9riaux. En g\u00e9n\u00e9ral, les mod\u00e8les \u00e0 tirage induit offrent la solution la plus efficace aux besoins de refroidissement de toute industrie.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Principe de la tour de refroidissement \u00e0 tirage m\u00e9canique<\/h2>\n\n\n\n<p>L&#039;eau de conditionnement qui s&#039;\u00e9coule est pulv\u00e9ris\u00e9e dans toute la station de refroidissement \u00e0 l&#039;aide d&#039;une t\u00eate de dispersion par pulv\u00e9risation dans une tour de refroidissement \u00e0 tirage induit. L&#039;eau s&#039;\u00e9coule verticalement \u00e0 travers des d\u00e9flecteurs pour maximiser le temps qu&#039;elle passe en contact avec l&#039;air.<\/p>\n\n\n\n<p>Le remplissage d&#039;eau de refroidissement, compos\u00e9 d&#039;Upvc, de bois, de m\u00e9tal ou d&#039;un autre \u00e9l\u00e9ment, maximise la zone de contact du transfert de chaleur.<\/p>\n\n\n\n<p>Gr\u00e2ce \u00e0 des \u00ab panneaux de carrosserie \u00bb correctement construits, l&#039;air p\u00e9n\u00e8tre \u00e0 l&#039;int\u00e9rieur de la tour de refroidissement. D&#039;\u00e9normes ventilateurs aspirent l&#039;air \u00e0 travers la r\u00e9gion d\u00e9flectrice, provoquant le refroidissement de l&#039;eau. Des dispositifs sp\u00e9ciaux appel\u00e9s \u00e9liminateurs de d\u00e9rives sont utilis\u00e9s pour emp\u00eacher les gouttelettes d&#039;eau de rester pi\u00e9g\u00e9es dans le flux d&#039;air qui s&#039;en va.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Avantages de la tour de refroidissement \u00e0 tirage m\u00e9canique<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>Faible capacit\u00e9 absorb\u00e9e.<\/li><li>Niveau sonore plus \u00e9lev\u00e9 que le tirage forc\u00e9.<\/li><li>Entra\u00eenement du flux d\u2019air humide.<\/li><li>N\u00e9cessite peu d&#039;espace pour l&#039;installation.<\/li><\/ul>\n\n\n\n<p>Dans une tour de tirage m\u00e9canique, le flux d&#039;air est cr\u00e9\u00e9 \u00e0 l&#039;aide d&#039;un ou plusieurs ventilateurs. Une tour de refroidissement \u00e0 tirage induit utilise les ventilateurs situ\u00e9s au sommet de la tour pour cr\u00e9er une zone de basse pression. Cela fait circuler l\u2019air depuis les c\u00f4t\u00e9s de la tour, jusqu\u2019au sommet. Dans cette situation, l\u2019eau p\u00e9n\u00e8tre par les canalisations d\u2019arriv\u00e9e et se r\u00e9pand dans les auges. Des buses dirigent l&#039;eau des auges vers le remplissage \u00e0 l&#039;int\u00e9rieur de la tour. Le garnissage ralentit l&#039;eau lorsqu&#039;elle tombe \u00e0 travers la tour et la brise \u00e9galement en petites gouttelettes. Ces deux actions permettent un meilleur transfert de chaleur. Alors que l&#039;eau descend en cascade \u00e0 travers la tour \u00e0 travers les couches de garniture, un ventilateur aspire l&#039;air \u00e0 travers un ensemble de persiennes, autour de la garniture, puis \u00e0 travers un \u00e9liminateur de d\u00e9rive. L&#039;\u00e9liminateur de d\u00e9rives pi\u00e8ge les gouttelettes d&#039;eau qui pourraient \u00eatre entra\u00een\u00e9es avec l&#039;air sortant de la tour. L\u2019eau est froide au moment o\u00f9 elle atteint le bassin collecteur. L&#039;eau froide est ensuite aspir\u00e9e hors de la tour par la conduite de sortie et renvoy\u00e9e vers l&#039;\u00e9quipement de l&#039;usine pour \u00eatre r\u00e9utilis\u00e9e.<\/p>\n\n\n\n<p>Un autre type de tour \u00e0 tirage m\u00e9canique est la tour de refroidissement \u00e0 tirage forc\u00e9. La principale diff\u00e9rence entre un tirage induit et une tour \u00e0 tirage forc\u00e9 est qu&#039;un tirage forc\u00e9 ne cr\u00e9e pas de zone de basse pression qui aspire l&#039;air \u00e0 travers la tour. Au lieu de cela, les ventilateurs forcent ou poussent l\u2019air vers le haut \u00e0 travers la tour. Les tours \u00e0 tirage forc\u00e9 n&#039;ont pas de persiennes sur les c\u00f4t\u00e9s, mais plut\u00f4t des ventilateurs avec des grilles qui dirigent le flux d&#039;air dans la tour. Lorsque l&#039;eau de refroidissement descend du haut de la tour, les ventilateurs poussent l&#039;air vers le haut \u00e0 travers la tour et le processus de transfert de chaleur a lieu.<\/p>\n\n\n\n<p>Certains composants sont communs \u00e0 la plupart des tours. Par exemple, de nombreuses tours sont divis\u00e9es en cellules. Chaque cellule contient tous les composants d&#039;une seule tour, sauf qu&#039;ils partagent un puisard commun. Pour mieux contr\u00f4ler le refroidissement, chaque cellule d\u2019une tour peut \u00eatre mise en service ou hors service ind\u00e9pendamment. D&#039;autres composants courants sont les lignes de purge et de maquillage. \u00c0 mesure que l\u2019eau dans la tour s\u2019\u00e9vapore, la concentration des impuret\u00e9s augmente et peut causer des probl\u00e8mes. Pour contr\u00f4ler la concentration d&#039;impuret\u00e9s, l&#039;eau est p\u00e9riodiquement \u00e9vacu\u00e9e du bassin de r\u00e9tention par la conduite de purge. Cette eau est ensuite remplac\u00e9e par de l\u2019eau propre via la ligne d\u2019appoint. Le d\u00e9bit \u00e0 travers la conduite d&#039;appoint est contr\u00f4l\u00e9 par une vanne de r\u00e9gulation qui comporte g\u00e9n\u00e9ralement un flotteur qui d\u00e9tecte le niveau dans le bassin de r\u00e9cup\u00e9ration. \u00c0 mesure que le niveau change, le flotteur change de position et envoie un signal \u00e0 la vanne de r\u00e9gulation qui r\u00e9gule le d\u00e9bit d&#039;eau dans le syst\u00e8me.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Balises associ\u00e9es :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/\">Soupape ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/gate-valve-problems.html\/\">R\u00e9paration de vannes \u00e0 vanne<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/advantages-and-disadvantages-of-globe-valves.html\/\">Qu'est-ce qu'un robinet \u00e0 soupape ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/the-function-of-globe-valve-in-pipeline-system.html\/\">Que sont les vannes \u00e0 soupape\u00a0?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/produit\/manual-gate-valve\/\">Fabricant de robinets-vannes \u00e0 commande manuelle<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-axial-flow-silent-check-valve.html\/\">Qu'est-ce qu'un clapet anti-retour axial ?<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/difference-between-gate-valve-and-butterfly-valve.html\/\">Diff\u00e9rence entre la vanne \u00e0 vanne et la vanne papillon<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">Qu'est-ce qu'un robinet-vanne ?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/fr\/tag\/shanghai-pressure-reducing-valve-factory\/\">Usine de soupapes de r\u00e9duction de pression de Shanghai<\/a>\n\n<\/div>\n\n\n<p><\/p>\n<p>Dix articles avant et apr\u00e8s<\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/hello-world.html\/\">Bonjour le monde!<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/gate-valve-vs-butterfly-valve-comprehensive-compare-guide.html\/\">Guide de comparaison complet des vannes \u00e0 vanne et des vannes papillon<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/how-to-measure-butterfly-valves.html\/\">Comment mesurer les vannes papillon<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/what-is-a-double-offset-butterfly-valve.html\/\">Qu&#039;est-ce qu&#039;une vanne papillon \u00e0 double excentration<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/how-to-fix-a-leaking-butterfly-valve.html\/\">Comment r\u00e9parer une vanne papillon qui fuit ?<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/pressure-reducing-valves-for-steam-opimization-zeco-valve-blog.html\/\">R\u00e9ducteurs de pression pour l&#039;optimisation de la vapeur | Blog des vannes Zeco<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/weld-in-place-ball-valves-a-unique-design-approach-zeco-valve-blog.html\/\">Vannes \u00e0 bille \u00e0 souder sur place \u2013 Une approche de conception unique | Blog des vannes Zeco<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/a-fluid-velocity-tutorial-zeco-valve-blog.html\/\">Un didacticiel sur la vitesse des fluides | Blog des vannes Zeco<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/hydrostatic-tank-level-measurement-zeco-valve-blog.html\/\">Mesure du niveau du r\u00e9servoir hydrostatique | Blog des vannes Zeco<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/fr\/resilient-seated-and-high-performance-butterfly-valves-zeco-valve-blog.html\/\">Vannes papillon \u00e0 si\u00e8ge r\u00e9silient et hautes performances | Blog des vannes Zeco<\/a><\/p>\n<p><!-- \/wam:article --><\/p>","protected":false},"excerpt":{"rendered":"<p>Dans de nombreuses installations industrielles, divers \u00e9quipements ainsi que de nombreux fluides utilis\u00e9s dans les syst\u00e8mes de traitement doivent \u00eatre refroidis. Ce \u2026 <a title=\"Tour de refroidissement \u00e0 tirage naturel &amp; Tour de refroidissement \u00e0 tirage m\u00e9canique\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/fr\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\" aria-label=\"Plus sur Tour de refroidissement \u00e0 tirage naturel &amp; Tour de refroidissement \u00e0 tirage m\u00e9canique\">Lire plus<\/a><\/p>","protected":false},"author":2,"featured_media":26718,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2383,2150,2749,2382,2384,2381],"class_list":["post-2165","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-cooling-tower-types","tag-cooling-tower-valves","tag-cooling-tower-valves-suppliers","tag-induced-draft-cooling-tower","tag-mechanical-draft-cooling-tower","tag-natural-draft-cooling-tower","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/deltacooling-product.jpg",690,540,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/fr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2383,"name":"cooling tower types","slug":"cooling-tower-types","term_group":0,"term_taxonomy_id":2383,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2150,"name":"Cooling Tower Valves","slug":"cooling-tower-valves","term_group":0,"term_taxonomy_id":2150,"taxonomy":"post_tag","description":"<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET COOLING TOWER VALVES PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_24532c-4c\"} \/-->\r\n\r\n<!-- wp:heading -->\r\n<h2>What are Cooling Towers?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCooling towers are a critical need for any industrial and manufacturing operation. Their role in extracting heat and delivering it to the atmosphere through evaporative cooling leverages the principle of heat rejection. The essential element of a cooling tower is water that is delivered through a piping system. These steady flow devices cool the water by evaporation with direct contact with the air. Evaporatively cooled equipment like cooling towers typically utilizes a multi-cell configuration. While these systems offer improved efficiency, operational flexibility, and advanced controls, they can only perform as well as their hardware is designed and built. One of the most important components of a cooling tower is its valves.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-cooling-tower-valves\">Cooling Tower Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCooling tower valves are devices designed to control, regulate, distribute, and allow, or disallow the passage of water through certain parts of the cooling tower\u2019s system. The different valves throughout a cooling tower system play an important role in their performance and the overall operation of your facility. The types of valves needed will depend on the flow capacity and the size of the piping in the cooling tower. Temperature and pressure are also critical considerations when it comes to valve selection.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Choosing Cooling Tower Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nRegarding cooling systems, the valves that are selected typically are going to be flow control valves and isolation (shutoff and bypass) valves. There are important questions to consider before picking the valve for the cooling system.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe first thing to consider is the flow capacity. When considering the size required by the cooling application, it is easy to narrow down the valve that should be chosen. An important thing to remember in valve selection is the pipe size.\r\nWhat flow capacity is needed for the cooling system?\r\nWhat size piping will be used?\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nTemperature and pressure are the next critical pieces to look at when determining the control valves to use for a cooling system. The valve pressure\/temperature rating must be within the system design parameters. The first factor that should be considered is the maximum pressure that the cooling system is going to have to hold to determine the valve rating. Along with pressure comes the capacity of the system. Consider the following three options when examining the pressure level and relative capacity of the cooling system:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Small-diameter pipe (0.5 to 2\u201d): globe control valve<\/li>\r\n \t<li>Mid-diameter pipe (3 to 6\u201d): segmented ball valve<\/li>\r\n \t<li>Large-diameter pipe (8\u201d and above): high performance butterfly valve (HPBV)<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDifferent types of isolation valves also are considered based on pressure and related capacity:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Small-diameter pipe: two piece ball valve or three piece ball valve<\/li>\r\n \t<li>Mid-diameter pipe: 3 piece ball valve or flanged ball valve<\/li>\r\n \t<li>Large-diameter pipe: butterfly valve<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe capacity of the system as it relates to the diameter of the piping is an important aspect to consider when putting the cooling system together.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":4,"filter":"raw"},{"term_id":2749,"name":"Cooling Tower Valves Suppliers","slug":"cooling-tower-valves-suppliers","term_group":0,"term_taxonomy_id":2749,"taxonomy":"post_tag","description":"<!-- wp:paragraph -->\r\n\r\nCooling towers are a critical need for any industrial and manufacturing operation. Their role in extracting heat and delivering it to the atmosphere through evaporative cooling leverages the principle of heat rejection. The essential element of a cooling tower is water that is delivered through a piping system. These steady flow devices cool the water by evaporation with direct contact with the air. Evaporatively cooled equipment like cooling towers typically utilizes a multi-cell configuration. While these systems offer improved efficiency, operational flexibility, and advanced controls, they can only perform as well as their hardware is designed and built. One of the most important components of a cooling tower is its valves. This is why ZECO offers cooling tower valves to optimize the performance of your cooling towers, reduce downtime, and eliminate maintenance.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_7bd7e9-a7\"} \/-->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET COOLING TOWER VALVES PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-what-is-cooling-tower-valve\">What is Cooling Tower Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCooling tower valves are devices designed to control, regulate, distribute, and allow, or disallow the passage of water through certain parts of the cooling tower\u2019s system. The different valves throughout a cooling tower system play an important role in their performance and the overall operation of your facility. The types of valves needed will depend on the flow capacity and the size of the piping in the cooling tower. Temperature and pressure are also critical considerations when it comes to valve selection.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Features of Cooling Tower Valves<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nZECO flow control valves have a simple &amp; reliable design and are available in the capacity range of 300 to 2200 m3\/h and size ranges of 150 to 300 NB. They are built specifically for cooling tower use and ensure low head losses. They are made of heavy-duty cast iron bodies and have a stainless steel valve stem. We also coat our control valves with a layer of the protective coating that resists corrosion.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:list -->\r\n<ul>\r\n \t<li>Simple and reliable design<\/li>\r\n \t<li>Low head loss<\/li>\r\n \t<li>Heavy-duty cast iron body and stainless steel valve stem<\/li>\r\n \t<li>Available in the capacity range from 300 to 2200 CMH<\/li>\r\n \t<li>Size range 150 NB to 500 NB<\/li>\r\n \t<li>Special protective coatings available for corrosive atmosphere<\/li>\r\n<\/ul>\r\n<!-- \/wp:list -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Cooling Tower Valves Suppliers<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>Magnatrol Valve Corp.<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nManufacturer of two-way bronze &amp; stainless steel solenoid valves designed for standard applications in sizes from 3\/8 in. to 3 in. for pressures up to 500 PSIG. Also manufacturer of two-way solenoid valves in sizes from 1\/4 in. to 2 in. for pressures up to 15,000 PSIG. Rotary Style valves designed to handle dirty &amp; viscous liquids, constructed of stainless steel, Monel, Hastelloy C &amp; Titanium available 1\/2 in. to 6 in. Fire link valves &amp; latching valves are also available.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>DFT Inc.<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nManufacturer of custom and standard cooling tower distribution valves. Various types include wafer check, flanged, sanitary, and restrictor valves. Available in various sizes. Suitable for liquid, gas, or steam applications. Building maintenance, chemical processing, food, beverage, pharmaceutical, gas transmission, mining, petroleum refining, power generation, pulp and paper, and textiles industries served. Meets ASME and ANSI standards.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading {\"level\":3} -->\r\n<h3>ZECO Valve<\/h3>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDistributor of steam specialty and fluid control devices. Products available include valves, pressure and temperature regulators, desuperheaters, noise reduction devices, steam separators and filters, condensate pump systems, steam traps, strainers, actuators, pneumatic controllers, pipe couplings, suction diffusers, condensate drains, steam filters, mufflers, pilots, noise suppressors, pressure transmitters, and unions. Steam traps, clean steam products, and cryogenic valves are also available.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":7,"filter":"raw"},{"term_id":2382,"name":"induced draft cooling tower","slug":"induced-draft-cooling-tower","term_group":0,"term_taxonomy_id":2382,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2384,"name":"mechanical draft cooling tower","slug":"mechanical-draft-cooling-tower","term_group":0,"term_taxonomy_id":2384,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2381,"name":"natural draft cooling tower","slug":"natural-draft-cooling-tower","term_group":0,"term_taxonomy_id":2381,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2383,"label":"cooling tower types"},{"value":2150,"label":"Cooling Tower Valves"},{"value":2749,"label":"Cooling Tower Valves Suppliers"},{"value":2382,"label":"induced draft cooling tower"},{"value":2384,"label":"mechanical draft cooling tower"},{"value":2381,"label":"natural draft cooling tower"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Natural Draft Cooling Tower &amp; Mechanical Draft Cooling Tower | ZECO<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/fr\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Natural Draft Cooling Tower &amp; Mechanical Draft Cooling Tower | ZECO\" \/>\n<meta property=\"og:description\" content=\"In many industrial facilities, various pieces of equipment, as well as many fluids used in process systems need to be cooled.&nbsp; This ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/fr\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-28T10:05:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-01T02:58:23+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/deltacooling-product.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"690\" \/>\n\t<meta property=\"og:image:height\" content=\"540\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\">\n\t<meta name=\"twitter:data2\" content=\"7 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/deltacooling-product.jpg\",\"width\":690,\"height\":540},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\",\"name\":\"Natural Draft Cooling Tower & Mechanical Draft Cooling Tower | ZECO\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#primaryimage\"},\"datePublished\":\"2021-12-28T10:05:18+00:00\",\"dateModified\":\"2022-11-01T02:58:23+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\",\"url\":\"https:\/\/zecovalve.com\/natural-draft-and-mechanical-draft-cooling-tower-fundamentals-zeco-valve-blog.html\",\"name\":\"Natural Draft Cooling Tower &#038; Mechanical Draft Cooling Tower\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/2165","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/comments?post=2165"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/posts\/2165\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media\/26718"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media?parent=2165"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/categories?post=2165"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/tags?post=2165"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}