{"id":17008,"date":"2022-06-25T13:07:59","date_gmt":"2022-06-25T13:07:59","guid":{"rendered":"https:\/\/zecovalve.com\/?post_type=product&#038;p=17008"},"modified":"2023-06-26T06:44:17","modified_gmt":"2023-06-26T06:44:17","slug":"single-orifice-air-release-valve","status":"publish","type":"product","link":"https:\/\/zecovalve.com\/fr\/produit\/single-orifice-air-release-valve","title":{"rendered":"Soupape de lib\u00e9ration d&#039;air \u00e0 orifice unique"},"content":{"rendered":"<div class=\"gb-button-wrapper gb-button-wrapper-31f123f4\">\r\n\r\n\r\n<p><a class=\"gb-button gb-button-504ddfe8 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong><strong>OBTENEZ LE PRIX DE LA SOUPAPE DE D\u00c9CHARGE D&#039;AIR \u00c0 ORIFICE UNIQUE<\/strong><\/strong><\/a><\/p>\r\n<\/div>\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Qu\u2019est-ce qui cause la pr\u00e9sence d\u2019air dans les conduites d\u2019eau\u00a0?<\/h2>\r\n\r\n\r\n\r\n<p>L&#039;air et le vide form\u00e9s dans les conduites d&#039;eau peuvent entra\u00eener de graves probl\u00e8mes de fonctionnement, voire des cons\u00e9quences dramatiques. L&#039;air peut p\u00e9n\u00e9trer dans les syst\u00e8mes de tuyauterie de plusieurs mani\u00e8res\u00a0:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Pipelines vides\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Les pipelines qui ne sont pas en service sont occup\u00e9s par de l&#039;air. La majeure partie est \u00e9vacu\u00e9e au d\u00e9marrage, mais certaines poches d&#039;air peuvent rester dans le syst\u00e8me.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Air dans le fluide\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>En fonction de la temp\u00e9rature et de la pression, les liquides comme l&#039;eau peuvent contenir de l&#039;air emprisonn\u00e9 ou dissous. Lors de l&#039;\u00e9coulement du fluide, il se s\u00e9pare du liquide et peut rester pi\u00e9g\u00e9 aux points hauts du syst\u00e8me. De plus, dans les canalisations transportant les eaux us\u00e9es, les d\u00e9chets liquides peuvent subir des r\u00e9actions chimiques et se transformer en gaz qui peuvent rester pi\u00e9g\u00e9s dans le syst\u00e8me de traitement des eaux us\u00e9es.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>\u00c9quipement m\u00e9canique\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>L&#039;air peut \u00e9galement p\u00e9n\u00e9trer dans la canalisation via des syst\u00e8mes m\u00e9caniques tels que des pompes, des joints de canalisations, des vannes, etc. Des fuites ou des joints d\u00e9fectueux dans ces composants peuvent entra\u00eener une infiltration d&#039;air dans le syst\u00e8me de canalisation.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Comment se forme le vide dans un tuyau ?<\/h2>\r\n\r\n\r\n\r\n<p>Les vides dans les pipelines se produisent lorsque la pression dans le pipeline descend en dessous de la pression atmosph\u00e9rique. Des vides peuvent appara\u00eetre en raison de changements brusques de la vitesse du fluide en \u00e9coulement. Par exemple:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Lorsque les pompes s&#039;arr\u00eatent trop vite<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Quand les vannes se ferment brusquement<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Vidage incorrect de sections de canalisation<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"h-what-is-a-single-orifice-air-release-valve\">Qu&#039;est-ce qu&#039;une soupape de d\u00e9charge d&#039;air \u00e0 orifice unique\u00a0?<\/h2>\r\n\r\n\r\n\r\n<p>Un seul orifice <a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"Soupape d&#039;air\" target=\"_blank\" rel=\"noopener\">Soupape d'air<\/a> parfois appel\u00e9e vanne \u00e0 \u00ab petit orifice \u00bb, elle lib\u00e8re continuellement l&#039;air accumul\u00e9 pendant le fonctionnement du syst\u00e8me. Lorsque l&#039;air du pipeline p\u00e9n\u00e8tre dans la vanne, il d\u00e9place l&#039;eau, permettant au flotteur de descendre. L&#039;air est ensuite rejet\u00e9 dans l&#039;atmosph\u00e8re par un petit orifice. Au fur et \u00e0 mesure que l&#039;air est \u00e9vacu\u00e9, il est remplac\u00e9. Un avantage suppl\u00e9mentaire d\u2019une vanne air\/vide est sa capacit\u00e9 \u00e0 fournir une protection contre le vide dans les pipelines. Si une pression n\u00e9gative se d\u00e9veloppe, la soupape de d\u00e9charge d&#039;air s&#039;ouvrira, admettant de l&#039;air dans la conduite et r\u00e9duisant ainsi le risque de surtensions li\u00e9es \u00e0 la s\u00e9paration de la colonne et \u00e0 un \u00e9ventuel effondrement du pipeline.<\/p>\r\n\r\n\r\n<div class=\"wp-block-image size-medium wp-image-17011\">\r\n<figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"264\" height=\"300\" class=\"wp-image-17011\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/single-orifice-air-release-valve-1-264x300.jpg\" alt=\"Soupape de lib\u00e9ration d&#039;air \u00e0 orifice unique\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/single-orifice-air-release-valve-1-264x300.jpg 264w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/single-orifice-air-release-valve-1.jpg 400w\" sizes=\"auto, (max-width: 264px) 100vw, 264px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Principaux composants des soupapes de d\u00e9charge d&#039;air \u00e0 orifice unique<\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Corps de soupape\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Le corps unique de la vanne en fonte ductile est compact et abrite les flotteurs internes et le m\u00e9canisme sup\u00e9rieur. Le corps est con\u00e7u de mani\u00e8re \u00e0 ce que l&#039;entr\u00e9e soit totalement exempte de guides de flotteur, permettant ainsi d&#039;utiliser les vannes papillon directement sous le <a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"Soupape d&#039;air\" target=\"_blank\" rel=\"noopener\">soupape d&#039;air<\/a> sans impacter les performances. Chaque corps de vanne est dot\u00e9 d&#039;une vanne de vidange inf\u00e9rieure inviolable de qualit\u00e9 316SS permettant \u00e0 la vanne d&#039;\u00eatre vidang\u00e9e et test\u00e9e rapidement et en toute s\u00e9curit\u00e9.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Ensembles de flotteurs int\u00e9rieurs\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Les flotteurs int\u00e9rieurs sont tous fabriqu\u00e9s \u00e0 partir de polypropyl\u00e8ne \u00e0 barres, ce qui garantit qu&#039;ils ne peuvent jamais changer de masse ou de forme. Les flotteurs sont tous guid\u00e9s et maintenus \u00e0 l&#039;\u00e9querre par rapport au corps par les quatre nervures de guidage sur le corps de la vanne, garantissant qu&#039;ils ne peuvent pas \u00eatre souffl\u00e9s de mani\u00e8re d\u00e9cal\u00e9e sur le c\u00f4t\u00e9.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\">Trois flotteurs aident \u00e0 produire les trois fonctions g\u00e9n\u00e9rales<\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Flotteur \u00e0 grand orifice\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Cela permet l&#039;entr\u00e9e et la sortie d&#039;air pendant le remplissage et la vidange.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Flotteur \u00e0 petit orifice\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Le flotteur \u00e0 petit orifice abrite le sous-ensemble de buse, garantissant que la vanne lib\u00e8re automatiquement tout air emprisonn\u00e9 lorsque le tuyau est plein et qu&#039;une poche d&#039;air se pr\u00e9sente dans la vanne.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Flotteur sup\u00e9rieur RFP\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Lors du remplissage du tuyau, ce flotteur restera ouvert pour remplir le tuyau \u00e0 un d\u00e9bit contr\u00f4l\u00e9. Si le d\u00e9bit de sortie d\u00e9passe un d\u00e9bit de fonctionnement s\u00fbr, il augmente imm\u00e9diatement et \u00e9touffe l&#039;\u00e9vacuation de l&#039;air jusqu&#039;\u00e0 un d\u00e9bit de fonctionnement s\u00fbr, \u00e9vitant ainsi les coups de b\u00e9lier.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Si\u00e8ge sup\u00e9rieur\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Le si\u00e8ge en acier inoxydable de qualit\u00e9 316S abrite intelligemment les joints toriques qui font flotter l&#039;\u00e9tanch\u00e9it\u00e9 entre le si\u00e8ge.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Sortie et couvercle en maille\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>La valve est dot\u00e9e d&#039;un maillage en acier inoxydable qui emp\u00eache toute possibilit\u00e9 de contaminants externes de p\u00e9n\u00e9trer dans les flotteurs int\u00e9rieurs et \u00e9loigne la vermine et les araign\u00e9es du dessous du couvercle. Le couvercle ductile est robuste et prot\u00e8ge les flotteurs de toute lumi\u00e8re directe du soleil et est suffisamment solide pour \u00eatre pos\u00e9 dessus s&#039;il est install\u00e9 \u00e0 l&#039;int\u00e9rieur d&#039;une fosse de vanne.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"h-features-of-single-orifice-air-release-valve\">Caract\u00e9ristiques de la soupape de d\u00e9charge d&#039;air \u00e0 orifice unique<\/h2>\r\n\r\n\r\n\r\n<p>Bien que les vannes d&#039;air\/vide \u00e9vacuent de grandes quantit\u00e9s d&#039;air au d\u00e9marrage, il ne faut pas oublier qu&#039;elles ne lib\u00e8rent pas d&#039;air en continu pendant le fonctionnement du syst\u00e8me. Pour cette fonction, un seul orifice <a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"Soupape d&#039;air\" target=\"_blank\" rel=\"noopener\">soupape d&#039;air<\/a> est \u00e9galement requis.<\/p>\r\n\r\n\r\n\r\n<p>La fonction d&#039;un orifice unique <a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"Soupape d&#039;air\" target=\"_blank\" rel=\"noopener\">soupape d&#039;air<\/a> est de permettre \u00e0 l&#039;air d&#039;\u00eatre expuls\u00e9 du syst\u00e8me pendant le remplissage et d&#039;admettre de l&#039;air dans le syst\u00e8me chaque fois qu&#039;une pression inf\u00e9rieure \u00e0 la pression atmosph\u00e9rique se produit. Lorsque l&#039;eau p\u00e9n\u00e8tre dans le corps de la vanne, la flottabilit\u00e9 du flotteur la soul\u00e8ve sur le si\u00e8ge et l&#039;augmentation r\u00e9sultante de la pression du syst\u00e8me assure une \u00e9tanch\u00e9it\u00e9 parfaite, la pression de la conduite maintenant le flotteur sur le si\u00e8ge. En cas d&#039;entr\u00e9e d&#039;air dans la vanne alors que la conduite est encore charg\u00e9e positivement, la vanne reste ferm\u00e9e. En cas de pression inf\u00e9rieure \u00e0 la pression atmosph\u00e9rique dans le syst\u00e8me, l&#039;eau est aspir\u00e9e du corps et le flotteur descend du si\u00e8ge pour admettre de l&#039;air dans le syst\u00e8me.<\/p>\r\n\r\n\r\n<div class=\"wp-block-image\">\r\n<figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" class=\"wp-image-17012\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/single-orifice-air-release-valve-1-1-300x225.jpg\" alt=\"\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/single-orifice-air-release-valve-1-1-300x225.jpg 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/single-orifice-air-release-valve-1-1.jpg 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"h-single-orifice-air-release-valve-working-principle\">Principe de fonctionnement de la soupape de d\u00e9charge d&#039;air \u00e0 orifice unique<\/h2>\r\n\r\n\r\n<div class=\"wp-block-image\">\r\n<figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" class=\"wp-image-17009\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/clean-water-air-release-valve-300x225.png\" alt=\"\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/clean-water-air-release-valve-300x225.png 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/clean-water-air-release-valve.png 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<p>Des vannes de purge d&#039;air automatiques sont install\u00e9es aux points les plus \u00e9lev\u00e9s d&#039;un pipeline o\u00f9 l&#039;air s&#039;accumule naturellement. Des bulles d&#039;air p\u00e9n\u00e8trent dans la valve et d\u00e9placent le liquide \u00e0 l&#039;int\u00e9rieur, abaissant ainsi le niveau de liquide. Lorsque le niveau descend au point o\u00f9 il ne soutient plus le flotteur, le flotteur descend. Ce mouvement \u00e9loigne le si\u00e8ge de l&#039;orifice, d\u00e9clenchant l&#039;ouverture de la vanne et l&#039;\u00e9vacuation de l&#039;air accumul\u00e9 dans l&#039;atmosph\u00e8re.<\/p>\r\n\r\n\r\n\r\n<p>Au fur et \u00e0 mesure que l&#039;air est purg\u00e9, le liquide rentre dans la vanne, soutenant \u00e0 nouveau le flotteur, le soulevant jusqu&#039;\u00e0 ce que le si\u00e8ge appuie contre l&#039;orifice, fermant ainsi la vanne. Ce cycle se r\u00e9p\u00e8te automatiquement aussi souvent que n\u00e9cessaire pour maintenir un syst\u00e8me sans air.<\/p>\r\n\r\n\r\n\r\n<p>Une installation correcte est essentielle au fonctionnement des soupapes de d\u00e9charge d\u2019air. \u00c9tant donn\u00e9 que ces vannes sont con\u00e7ues pour \u00e9vacuer l&#039;air du syst\u00e8me de tuyauterie, elles doivent \u00eatre plac\u00e9es l\u00e0 o\u00f9 l&#039;air est le plus susceptible de s&#039;accumuler. Installez-les aux points hauts du syst\u00e8me en position verticale avec l&#039;entr\u00e9e vers le bas. N&#039;oubliez pas d&#039;ajouter une vanne d&#039;arr\u00eat sous la vanne au cas o\u00f9 un entretien serait n\u00e9cessaire.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"h-single-orifice-air-release-valve-installation-and-commissioning\">Installation et mise en service d&#039;une vanne de purge d&#039;air \u00e0 orifice unique<\/h2>\r\n\r\n\r\n<div class=\"wp-block-image\">\r\n<figure class=\"aligncenter\"><img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" class=\"wp-image-17010\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/clean-water-air-release-valve-installation-and-commissioning-300x225.png\" alt=\"\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/clean-water-air-release-valve-installation-and-commissioning-300x225.png 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/clean-water-air-release-valve-installation-and-commissioning.png 600w\" sizes=\"auto, (max-width: 300px) 100vw, 300px\" \/><\/figure>\r\n<\/div>\r\n\r\n\r\n<p>Choisir le bon emplacement pour l&#039;installation d&#039;un <a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"Soupape d&#039;air\" target=\"_blank\" rel=\"noopener\">soupape d&#039;air<\/a> c&#039;est tres important. Pour obtenir une efficacit\u00e9 maximale, les vannes d&#039;air sont plac\u00e9es \u00e0 des endroits strat\u00e9giques sur le parcours du pipeline. Pour une a\u00e9ration et une ventilation ad\u00e9quates des syst\u00e8mes d\u2019eau et d\u2019eaux us\u00e9es, des vannes d\u2019air sont n\u00e9cessaires aux points suivants\u00a0:<\/p>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li><strong>Nombre maximum de points \u00e9lev\u00e9s<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Les bulles d&#039;air s&#039;accumulent et forment des poches d&#039;air qui restent coinc\u00e9es aux points les plus \u00e9lev\u00e9s du syst\u00e8me. Placer des vannes d&#039;air ici aide \u00e0 ventiler les poches d&#039;air vers l&#039;atmosph\u00e8re. Valve requise\u00a0:\u00a0Valve de d\u00e9charge d&#039;air\/valve combin\u00e9e.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li><strong>Points forts temporaires<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Les points culminants locaux peuvent \u00e9galement servir de point d\u2019accumulation de bulles d\u2019air. Un <a href=\"https:\/\/zecovalve.com\/fr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\" data-internallinksmanager029f6b8e52c=\"1\" title=\"Soupape d&#039;air\" target=\"_blank\" rel=\"noopener\">soupape d&#039;air<\/a> ici, les bulles sont \u00e9vacu\u00e9es vers l&#039;atmosph\u00e8re. Valve requise\u00a0:\u00a0Valve de d\u00e9charge d&#039;air\/valve combin\u00e9e.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li><strong>Longues sections de tuyaux montantes ou descendantes<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Les poches d&#039;air d\u00e9log\u00e9es peuvent s&#039;\u00e9couler vers l&#039;aval et former des poches d&#039;air plus grandes dans la partie sup\u00e9rieure du tuyau. En outre, un \u00e9coulement rapide dans des sections de tuyaux inclin\u00e9es vers le bas peut former un vide. En r\u00e8gle g\u00e9n\u00e9rale, des vannes de purge d&#039;air et des vannes de vide d&#039;air doivent \u00eatre install\u00e9es tous les 800 m sur les longs tron\u00e7ons de canalisations afin d&#039;\u00e9vacuer et d&#039;aspirer correctement l&#039;air dans le syst\u00e8me.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li><strong>Longues sections de tuyaux montantes ou descendantes<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Les poches d&#039;air d\u00e9log\u00e9es peuvent s&#039;\u00e9couler vers l&#039;aval et former des poches d&#039;air plus grandes dans la partie sup\u00e9rieure du tuyau. En outre, un \u00e9coulement rapide dans des sections de tuyaux inclin\u00e9es vers le bas peut former un vide. En r\u00e8gle g\u00e9n\u00e9rale, des vannes de purge d&#039;air et des vannes de vide d&#039;air doivent \u00eatre install\u00e9es tous les 800 m sur les longs tron\u00e7ons de canalisations afin d&#039;\u00e9vacuer et d&#039;aspirer correctement l&#039;air dans le syst\u00e8me.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li><strong>Apr\u00e8s fermeture rapide des vannes<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Lorsque les vannes sont soudainement ferm\u00e9es, des vides peuvent se former en aval de la vanne en raison de l&#039;impulsion du d\u00e9bit. Pour le bon fonctionnement du tuyau, la pression n\u00e9gative doit \u00eatre rel\u00e2ch\u00e9e en admettant de l&#039;air dans le tuyau.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li><strong>Apr\u00e8s les dispositifs de limitation\/de suralimentation du d\u00e9bit<\/strong>\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Apr\u00e8s les dispositifs d&#039;\u00e9tranglement de d\u00e9bit comme les turbines ou les vannes de r\u00e9gulation, les diff\u00e9rences de pression et de vitesse peuvent conduire \u00e0 la formation d&#039;un vide. Des vannes \u00e0 vide d&#039;air sont n\u00e9cessaires \u00e0 proximit\u00e9 de ces appareils pour aspirer l&#039;air dans le syst\u00e8me. Les dispositifs augmentant le d\u00e9bit comme les pompes et les sections de tuyaux r\u00e9duites attirent \u00e9galement des bulles d&#039;air dans le flux. Des vannes de purge d&#039;air doivent \u00eatre install\u00e9es apr\u00e8s ces dispositifs pour \u00e9vacuer ces poches d&#039;air.<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<p>Enfin, installez toujours vos vannes d&#039;air dans des endroits accessibles et bien ventil\u00e9s. Cela garantit qu\u2019ils ont toujours suffisamment d\u2019air \u00e0 aspirer dans les syst\u00e8mes et que l\u2019air expuls\u00e9 peut sortir. De plus, cela facilite l\u2019acc\u00e8s aux vannes pour l\u2019entretien.<\/p>\r\n\r\n\r\n\r\n<h2 class=\"wp-block-heading\" id=\"h-single-orifice-air-release-valve-material-and-standard\">Mat\u00e9riau et norme de la soupape de d\u00e9charge d&#039;air \u00e0 orifice unique<\/h2>\r\n\r\n\r\n\r\n<ul class=\"wp-block-list\">\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Gamme de tailles\u00a0: 3\/4\u2033~2\u2033<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Pression nominale\u00a0: 10 bars ~ 25 bars<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Dimensions face \u00e0 face\u00a0: EN 558-1, ASME B 16.10<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Dimension d&#039;extr\u00e9mit\u00e9 de bride\u00a0: BS 21<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Rev\u00eatement\u00a0: rev\u00eatement \u00e9poxy li\u00e9 par fusion<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<ul>\r\n<li style=\"list-style-type: none;\">\r\n<ul>\r\n<li>Inspection et test\u00a0: ISO 5208 \/ EN 12226-2<\/li>\r\n<\/ul>\r\n<\/li>\r\n<\/ul>\r\n\r\n\r\n\r\n<figure class=\"wp-block-table is-style-stripes\">\r\n<table>\r\n<tbody>\r\n<tr>\r\n<td>Partie<\/td>\r\n<td>Mat\u00e9riau<\/td>\r\n<td>Standard<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Corps<\/td>\r\n<td>Fonte Ductile<\/td>\r\n<td>EN 1563\/DIN 1693<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Bonnet<\/td>\r\n<td>Fonte Ductile<\/td>\r\n<td>EN 1563\/DIN 1693<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Hotte aspirante<\/td>\r\n<td>EPDM\/NBR<\/td>\r\n<td>OIN 4633<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Ballon flottant<\/td>\r\n<td>Acier inoxydable 431<\/td>\r\n<td>EN10088-1\/ASTM A959<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>Cr\u00e9maill\u00e8re \u00e0 pistons<\/td>\r\n<td>Acier inoxydable 431<\/td>\r\n<td>EN10088-1\/ASTM A959<\/td>\r\n<\/tr>\r\n<tr>\r\n<td>R\u00e9servoir<\/td>\r\n<td>EPDM\/NBR<\/td>\r\n<td>OIN 4633<\/td>\r\n<\/tr>\r\n<\/tbody>\r\n<\/table>\r\n<\/figure>","protected":false},"excerpt":{"rendered":"<p>Qu\u2019est-ce qui cause la pr\u00e9sence d\u2019air dans les conduites d\u2019eau\u00a0? L&#039;air et le vide form\u00e9s dans les conduites d&#039;eau peuvent entra\u00eener de graves probl\u00e8mes de fonctionnement et m\u00eame certains\u2026 <a title=\"Soupape de lib\u00e9ration d&#039;air \u00e0 orifice unique\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/fr\/produit\/single-orifice-air-release-valve\" aria-label=\"Plus sur Single Orifice Air Release Valve\">Lire plus<\/a><\/p>","protected":false},"featured_media":27968,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":""},"product_cat":[2520],"product_tag":[2796,2654,2765],"class_list":["post-17008","product","type-product","status-publish","has-post-thumbnail","hentry","product_cat-air-valve","product_tag-air-vent-valve","product_tag-hvac-valve","product_tag-vent-valve","sales-flash-overlay","woocommerce-text-align-center","woocommerce-image-align-center","do-quantity-buttons"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Single-Orifice-Air-Release-Valve-2.jpg",800,600,false],"author_info":[],"comment_info":0,"taxonomy_info":{"product_cat":[{"value":2520,"label":"Air Valve Manufacturer and Supplier"}],"product_tag":[{"value":2796,"label":"Air Vent Valve"},{"value":2654,"label":"HVAC Valve"},{"value":2765,"label":"Vent Valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Single Orifice Air Release Valve - Air Release Valve Working Principle | ZECO<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/fr\/produit\/single-orifice-air-release-valve\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Single Orifice Air Release Valve - Air Release Valve Working Principle | ZECO\" \/>\n<meta property=\"og:description\" content=\"What Causes Air in Water Pipes? Air and vacuum formed in water mains may lead to serious operating problems and even some ... Lire plus\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/fr\/produit\/single-orifice-air-release-valve\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:modified_time\" content=\"2023-06-26T06:44:17+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Single-Orifice-Air-Release-Valve-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\">\n\t<meta name=\"twitter:data2\" content=\"6 minutes\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve#primaryimage\",\"inLanguage\":\"fr-FR\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/Single-Orifice-Air-Release-Valve-2.jpg\",\"width\":800,\"height\":600,\"caption\":\"Single Orifice Air Release Valve\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve#webpage\",\"url\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve\",\"name\":\"Single Orifice Air Release Valve - Air Release Valve Working Principle | ZECO\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve#primaryimage\"},\"datePublished\":\"2022-06-25T13:07:59+00:00\",\"dateModified\":\"2023-06-26T06:44:17+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/product-category\",\"url\":\"https:\/\/zecovalve.com\/product-category\",\"name\":\"Industrial Valve Manufacturer | Water Valve Manufacturer\"}},{\"@type\":\"ListItem\",\"position\":3,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve\",\"url\":\"https:\/\/zecovalve.com\/product\/single-orifice-air-release-valve\",\"name\":\"Single Orifice Air Release Valve\"}}]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/product\/17008","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/comments?post=17008"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media\/27968"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/media?parent=17008"}],"wp:term":[{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/product_cat?post=17008"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/fr\/wp-json\/wp\/v2\/product_tag?post=17008"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}