{"id":2442,"date":"2021-12-28T10:11:57","date_gmt":"2021-12-28T10:11:57","guid":{"rendered":"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html"},"modified":"2022-08-13T13:23:44","modified_gmt":"2022-08-13T13:23:44","slug":"steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/pt\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html","title":{"rendered":"Manuten\u00e7\u00e3o do Purgador de Vapor"},"content":{"rendered":"<h3 class=\"wp-block-heading\" id=\"h-steam-trap-maintenance-made-easier-with-pipeline-connector\">Manuten\u00e7\u00e3o do purgador de vapor facilitada com conector de tubula\u00e7\u00e3o<\/h3>\n\n\n\n<p>O vapor \u00e9 uma fonte comum de calor ou energia em instala\u00e7\u00f5es industriais e comerciais. A maioria dos sistemas de vapor opera como um sistema fechado, com retorno de condensado para maximizar a efici\u00eancia energ\u00e9tica e obter outros benef\u00edcios operacionais. Os purgadores de vapor s\u00e3o o carro-chefe de muitos sistemas de retorno de condensado, direcionando o condensado de volta para a caldeira e os gases n\u00e3o condens\u00e1veis para fora do sistema, tudo sem grande perda de vapor.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">O que \u00e9 um purgador de vapor?<\/h2>\n\n\n\n<p>Um purgador de vapor \u00e9 um mecanismo que filtra o condensado (ou seja, vapor condensado) e gases n\u00e3o condens\u00e1veis. Isso \u00e9 feito sem remover o vapor ativo do sistema.<\/p>\n\n\n\n<p>Dependendo do sistema de vapor, a quantidade de vapor condensado que o purgador pode transportar varia. O purgador pode descarregar o condensado assim que o vapor condensado se formar ou pode ficar abaixo da temperatura do vapor.<\/p>\n\n\n\n<p>Ao escolher a armadilha certa para o seu sistema, voc\u00ea deseja garantir que ela possa executar as fun\u00e7\u00f5es fornecidas, independentemente da condi\u00e7\u00e3o. Se voc\u00ea n\u00e3o tiver certeza de quais s\u00e3o os requisitos, experimente press\u00f5es operacionais, carga de calor ou press\u00e3o de condensa\u00e7\u00e3o contrastantes. Al\u00e9m disso, os purgadores de vapor cont\u00eam diferentes extremos de temperatura ou golpes de ar\u00edete. N\u00e3o importa a(s) condi\u00e7\u00e3o(\u00f5es), corrija a sele\u00e7\u00e3o do purgador de vapor para melhorar a efici\u00eancia do seu sistema.<\/p>\n\n\n\n<p>Os purgadores de vapor s\u00e3o pontos de alta manuten\u00e7\u00e3o no sistema de vapor. Eles tamb\u00e9m s\u00e3o parte integrante do sistema, o que significa que est\u00e3o sob press\u00e3o. A manuten\u00e7\u00e3o do purgador de vapor requer o isolamento do purgador do sistema, liberando a press\u00e3o dentro da se\u00e7\u00e3o isolada e removendo o l\u00edquido que possa estar contido no purgador.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full\"><img decoding=\"async\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/20211230060819-61cd4cd30a33b.jpg\" alt=\"\" class=\"wp-image-5421\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Duas das causas mais comuns de falha do purgador de vapor<\/h2>\n\n\n\n<p>Duas das causas mais comuns de falha do purgador de vapor s\u00e3o o superdimensionamento e a sujeira no sistema. O superdimensionamento pode causar excesso de trabalho nos purgadores, enquanto o ac\u00famulo de sujeira pode causar entupimento ou impedir o fechamento de uma v\u00e1lvula. Para ajud\u00e1-lo a avaliar melhor a falha do purgador de vapor, aqui est\u00e3o algumas indica\u00e7\u00f5es gerais a serem observadas:<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Uma sala de caldeira anormalmente quenteJourneyman Inspecting A Boiler<\/li><li>Condensado recebendo vapor de ventila\u00e7\u00e3o<\/li><li>A veda\u00e7\u00e3o de \u00e1gua da bomba de condensado est\u00e1 falhando prematuramente<\/li><li>Superaquecimento ou subaquecimento em um espa\u00e7o condicionado<\/li><li>A press\u00e3o operacional da caldeira \u00e9 dif\u00edcil de manter<\/li><li>O v\u00e1cuo nas linhas de retorno \u00e9 dif\u00edcil de manter<\/li><li>H\u00e1 um golpe de ar\u00edete nas linhas de vapor e condensado<\/li><li>Ac\u00famulo de vapor nas linhas de retorno de condensado<\/li><li>A conta de energia est\u00e1 mais alta que o normal<\/li><li>As linhas de entrada e sa\u00edda t\u00eam as mesmas temperaturas<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">Manuten\u00e7\u00e3o de purgadores de vapor<\/h2>\n\n\n\n<p><strong>Manuten\u00e7\u00e3o de rotina<\/strong><\/p>\n\n\n\n<p>A manuten\u00e7\u00e3o de rotina depende do tipo de purgador e da sua aplica\u00e7\u00e3o. O purgador de press\u00e3o balanceada, por exemplo, possui um elemento projetado para f\u00e1cil substitui\u00e7\u00e3o. Alter\u00e1-los regularmente, talvez uma vez a cada tr\u00eas anos ou mais, pode parecer um desperd\u00edcio de tempo e materiais. Contudo, esta pr\u00e1tica reduz a necessidade de verifica\u00e7\u00e3o de purgadores e deve garantir um sistema livre de problemas com perdas m\u00ednimas atrav\u00e9s de purgadores defeituosos.<\/p>\n\n\n\n<p>A manuten\u00e7\u00e3o de rotina que envolve limpeza e reutiliza\u00e7\u00e3o de componentes internos existentes consome a mesma quantidade de m\u00e3o-de-obra, mas deixa um purgador de vapor n\u00e3o confi\u00e1vel. Ter\u00e1 que ser verificado de vez em quando e estar\u00e1 sujeito \u00e0 fadiga. Qualquer manuten\u00e7\u00e3o de rotina deve incluir a renova\u00e7\u00e3o de quaisquer pe\u00e7as suspeitas para que seja rent\u00e1vel.<\/p>\n\n\n\n<p><strong>Substitui\u00e7\u00e3o de pe\u00e7as<\/strong><\/p>\n\n\n\n<p>Renovar as pe\u00e7as internas de um purgador pode economizar tempo e dinheiro. Como o corpo do sif\u00e3o provavelmente durar\u00e1 tanto quanto a planta na qual est\u00e1 instalado, faz mais sentido substituir as pe\u00e7as internas em vez de retirar o sif\u00e3o inteiro e instalar um novo. Um exemplo disso est\u00e1 nos purgadores de vapor termodin\u00e2micos. Se a sede ou as faces do disco de um purgador termodin\u00e2mico estiverem danificadas, o disco pode simplesmente ser substitu\u00eddo. Os elementos dos purgadores termost\u00e1ticos geralmente podem ser trocados simplesmente removendo uma sede aparafusada. A substitui\u00e7\u00e3o \u00e9 f\u00e1cil e o purgador refeito ser\u00e1 confi\u00e1vel desde que a manuten\u00e7\u00e3o seja realizada corretamente.<\/p>\n\n\n\n<p><strong>Cronogramas de Manuten\u00e7\u00e3o Preventiva<\/strong><\/p>\n\n\n\n<p>A regra geral para a manuten\u00e7\u00e3o preventiva do purgador de vapor \u00e9 que quanto maior a press\u00e3o, mais frequente ser\u00e1 o teste. Por exemplo, purgadores de alta press\u00e3o com taxas superiores a 250 PSIG devem ser testados diariamente. Entretanto, purgadores de baixa press\u00e3o com taxas abaixo de 30 PSIG podem ser verificados mensalmente ou at\u00e9 anualmente. Em m\u00e9dia, os purgadores de vapor s\u00e3o substitu\u00eddos a cada tr\u00eas ou quatro anos.<\/p>\n\n\n\n<p><strong>Lista de verifica\u00e7\u00e3o de manuten\u00e7\u00e3o preventiva<\/strong><\/p>\n\n\n\n<p>Quando os t\u00e9cnicos de manuten\u00e7\u00e3o inspecionam purgadores de vapor, eles devem prestar aten\u00e7\u00e3o \u00e0 temperatura, press\u00e3o, condensa\u00e7\u00e3o e opera\u00e7\u00e3o adequada do equipamento. Por exemplo, uma sala de caldeira quente, a temperatura incorreta do espa\u00e7o condicionado ou uma conta de energia alta podem indicar falha no purgador de vapor. A veda\u00e7\u00e3o h\u00eddrica da bomba, a press\u00e3o operacional da caldeira e o v\u00e1cuo nas linhas de retorno tamb\u00e9m devem ser verificados.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Benef\u00edcios da manuten\u00e7\u00e3o do purgador de vapor<\/h2>\n\n\n\n<p>Os benef\u00edcios da manuten\u00e7\u00e3o preventiva mant\u00eam os purgadores de vapor funcionando corretamente, criam um ambiente de trabalho mais seguro e economizam energia em suas instala\u00e7\u00f5es.<\/p>\n\n\n\n<p>Se um purgador de vapor criar um backup de condensado dentro do sistema, isso poder\u00e1 afetar a velocidade do vapor. Um purgador de vapor operando incorretamente pode aumentar a for\u00e7a do golpe de ar\u00edete e estourar um filtro ou v\u00e1lvula. Este \u00e9 um risco potencial \u00e0 seguran\u00e7a, bem como um risco de danos adicionais ao equipamento.<\/p>\n\n\n\n<p>Os purgadores de vapor presos abertos permitem que o vapor escape continuamente, desperdi\u00e7ando energia enquanto esta condi\u00e7\u00e3o n\u00e3o for reconhecida. De acordo com a Industrial Controls, um purgador de vapor que n\u00e3o recebe manuten\u00e7\u00e3o pode custar milhares de d\u00f3lares em energia perdida por ano.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Etiquetas relacionadas :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/\">V\u00e1lvula ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/globe-valve\/\">Fabricante de v\u00e1lvula globo - V\u00e1rios tipos de v\u00e1lvula globo<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/gate-valve\/\">Fabricante de v\u00e1lvula gaveta - v\u00e1rios tipos de v\u00e1lvula gaveta<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/ball-valve\/\">Fabricante de v\u00e1lvula esf\u00e9rica - V\u00e1rios tipos de v\u00e1lvula esf\u00e9rica<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/butterfly-valve\/\">Fabricante de v\u00e1lvula borboleta - v\u00e1rios tipos de v\u00e1lvula borboleta<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/balancing-valve\/\">V\u00e1lvula de balanceamento \u2013 V\u00e1lvula HVAC<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/check-valve\/\">Fabricante de v\u00e1lvula de reten\u00e7\u00e3o \u2013 V\u00e1rios tipos de v\u00e1lvula de reten\u00e7\u00e3o<\/a>\n\n<\/div>\n\n\n\n<p>Dez artigos antes e depois<\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/zeco-valve-expands-product-offering-zeco-valve-blog.html\/\">Zeco Valve expande oferta de produtos | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/appropriate-application-for-pressure-regulator-valve-and-back-pressure-regulator-zeco-valve-blog.html\/\">Aplica\u00e7\u00e3o apropriada para v\u00e1lvula reguladora de press\u00e3o e regulador de contrapress\u00e3o | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/specially-designed-heat-exchangers-deliver-hot-water-on-demand-zeco-valve-blog.html\/\">Trocadores de calor especialmente projetados fornecem \u00e1gua quente sob demanda | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/pressure-regulating-valves-zeco-valve-blog.html\/\">V\u00e1lvulas Reguladoras de Press\u00e3o | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/power-generation-conversion-from-coal-to-gas-impact-on-valves-zeco-valve-blog.html\/\">Convers\u00e3o de gera\u00e7\u00e3o de energia de carv\u00e3o para g\u00e1s \u2013 impacto nas v\u00e1lvulas | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/summary-of-technologies-used-for-continuous-liquid-level-measurement-in-industrial-process-control-zeco-valve-blog.html\/\">Resumo das tecnologias utilizadas para medi\u00e7\u00e3o cont\u00ednua de n\u00edvel de l\u00edquido no controle de processos industriais | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/replacing-heat-exchanger-tube-bundles-zeco-valve-blog.html\/\">Substituindo feixes de tubos do trocador de calor | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/the-rack-and-pinion-style-pneumatic-actuator-zeco-valve-blog.html\/\">O atuador pneum\u00e1tico estilo cremalheira e pinh\u00e3o | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/case-study-from-csb-industrial-plant-heat-exchanger-explosion-zeco-valve-blog.html\/\">Estudo de caso da CSB: Explos\u00e3o de trocador de calor em planta industrial | Blog da V\u00e1lvula Zeco<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/pt\/floating-ball-valves-zeco-valve-blog.html\/\">V\u00e1lvulas de esfera flutuantes | Blog da V\u00e1lvula Zeco<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Manuten\u00e7\u00e3o do purgador de vapor facilitada com o conector de tubula\u00e7\u00e3o O vapor \u00e9 uma fonte comum de calor ou energia em instala\u00e7\u00f5es industriais e comerciais. \u2026 <a title=\"Manuten\u00e7\u00e3o do Purgador de Vapor\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/pt\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\" aria-label=\"Mais em Manuten\u00e7\u00e3o de purgadores de vapor\">Ler mais<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2362,3588,3589,3590,3592,3591],"class_list":["post-2442","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-steam-trap","tag-steam-trap-maintenance","tag-steam-trap-maintenance-checklist","tag-steam-trap-maintenance-frequency","tag-steam-trap-maintenance-program","tag-steam-trap-preventive-maintenance-checklist","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/pt\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2362,"name":"steam trap","slug":"steam-trap","term_group":0,"term_taxonomy_id":2362,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3588,"name":"steam trap maintenance","slug":"steam-trap-maintenance","term_group":0,"term_taxonomy_id":3588,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3589,"name":"steam trap maintenance checklist","slug":"steam-trap-maintenance-checklist","term_group":0,"term_taxonomy_id":3589,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3590,"name":"steam trap maintenance frequency","slug":"steam-trap-maintenance-frequency","term_group":0,"term_taxonomy_id":3590,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3592,"name":"steam trap maintenance program","slug":"steam-trap-maintenance-program","term_group":0,"term_taxonomy_id":3592,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3591,"name":"steam trap preventive maintenance checklist","slug":"steam-trap-preventive-maintenance-checklist","term_group":0,"term_taxonomy_id":3591,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2362,"label":"steam trap"},{"value":3588,"label":"steam trap maintenance"},{"value":3589,"label":"steam trap maintenance checklist"},{"value":3590,"label":"steam trap maintenance frequency"},{"value":3592,"label":"steam trap maintenance program"},{"value":3591,"label":"steam trap preventive maintenance checklist"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Steam Trap Maintenance | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/pt\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Steam Trap Maintenance | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"Steam Trap Maintenance Made Easier With Pipeline Connector Steam is a common source of heat or power throughout industrial and commercial installations. ... Ler mais\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/pt\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-28T10:11:57+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-13T13:23:44+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\">\n\t<meta name=\"twitter:data2\" content=\"4 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html#primaryimage\",\"inLanguage\":\"pt-PT\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/20211230060819-61cd4cd30a33b.jpg\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\",\"name\":\"Steam Trap Maintenance | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html#primaryimage\"},\"datePublished\":\"2021-12-28T10:11:57+00:00\",\"dateModified\":\"2022-08-13T13:23:44+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\",\"url\":\"https:\/\/zecovalve.com\/steam-trap-maintenance-made-easier-with-pipeline-connector-zeco-valve-blog.html\",\"name\":\"Steam Trap Maintenance\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/posts\/2442","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/comments?post=2442"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/posts\/2442\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/media?parent=2442"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/categories?post=2442"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/tags?post=2442"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}