{"id":8523,"date":"2021-12-30T07:23:26","date_gmt":"2021-12-30T07:23:26","guid":{"rendered":"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html"},"modified":"2022-08-13T11:28:09","modified_gmt":"2022-08-13T11:28:09","slug":"news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/pt\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html","title":{"rendered":"Princ\u00edpio de funcionamento da v\u00e1lvula globo el\u00e9trica e do atuador el\u00e9trico"},"content":{"rendered":"<p>Com as mais altas classifica\u00e7\u00f5es de press\u00e3o de fechamento, modelos rosqueados ou flangeados e op\u00e7\u00f5es de acabamento em ferro, lat\u00e3o ou a\u00e7o inoxid\u00e1vel \u2013 procure a Schneider Electric para obter a melhor solu\u00e7\u00e3o de v\u00e1lvula globo e atuador.<\/p>\n\n\n\n\n\n<h2 class=\"wp-block-heading\">O que \u00e9 um <strong><a href=\"https:\/\/zecovalve.com\/pt\/produto\/two-way-globe-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\"><mark style=\"background-color:var(--base)\" class=\"has-inline-color has-contrast-2-color\">V\u00e1lvula globo el\u00e9trica<\/mark><\/a><\/strong>?<\/h2>\n\n\n\n<p>As v\u00e1lvulas Globo El\u00e9tricas, como qualquer outro tipo de v\u00e1lvula, precisam de uma fonte de energia para serem operadas. Somos uma empresa de v\u00e1lvulas e atuadores.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-full is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/two-way-globe-valve.jpg\" alt=\"V\u00e1lvula de globo de duas vias\" class=\"wp-image-17036\" width=\"330\" height=\"300\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/two-way-globe-valve.jpg 330w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/two-way-globe-valve-300x273.jpg 300w\" sizes=\"auto, (max-width: 330px) 100vw, 330px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-how-does-an-electric-globe-valve-work\">Como funciona uma v\u00e1lvula globo el\u00e9trica?<\/h2>\n\n\n\n<p>Uma v\u00e1lvula Globo El\u00e9trica \u00e9 uma v\u00e1lvula com um atuador el\u00e9trico que move a haste para cima e para baixo para acionar a cabe\u00e7a da v\u00e1lvula, de modo a alterar a dist\u00e2ncia entre o disco e a sede para obter o controle de abertura e fechamento. \u00c9 usado principalmente para cortar ou distribuir a dire\u00e7\u00e3o do fluxo na tubula\u00e7\u00e3o. \u00c9 a produ\u00e7\u00e3o qu\u00edmica no uso da mais ampla faixa de v\u00e1lvula de corte. A v\u00e1lvula de corte el\u00e9trica \u00e9 utilizada principalmente no controle de \u00e1gua, vapor e ar comprimido, mas n\u00e3o \u00e9 adequada para materiais com alta viscosidade e f\u00e1cil cristaliza\u00e7\u00e3o. Na utiliza\u00e7\u00e3o da principal forma de avaliar o estado aberto e fechado da v\u00e1lvula \u00e9 observar a haste exposta \u00e0 altura da tampa, a fim de controlar o funcionamento da v\u00e1lvula.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Princ\u00edpio de funcionamento do atuador el\u00e9trico<\/h2>\n\n\n\n<p>O princ\u00edpio b\u00e1sico de funcionamento dos atuadores lineares el\u00e9tricos \u00e9 converter o movimento rotativo em movimento linear. Esta convers\u00e3o de movimento \u00e9 feita com a ajuda de uma caixa de engrenagens e de um parafuso de avan\u00e7o. Estas s\u00e3o as duas pe\u00e7as mais importantes do atuador linear el\u00e9trico.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-7-advantages-of-electric-globe-valve\">7 vantagens da v\u00e1lvula globo el\u00e9trica<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>A resist\u00eancia do fluido \u00e9 pequena e seu coeficiente de resist\u00eancia \u00e9 igual ao comprimento da se\u00e7\u00e3o do tubo.<\/li><li>O modelo de utilidade tem as vantagens de estrutura simples, pequeno volume e peso leve.<\/li><li>Apertado e confi\u00e1vel, o material da superf\u00edcie de veda\u00e7\u00e3o da v\u00e1lvula gaveta \u00e9 pl\u00e1stico amplamente utilizado, e uma boa veda\u00e7\u00e3o no sistema de v\u00e1cuo tamb\u00e9m tem sido amplamente utilizada.<\/li><li>F\u00e1cil de operar, abre e fecha rapidamente, da abertura total ao fechamento total, desde que a rota\u00e7\u00e3o de 90\u00b0, para controle de longa dist\u00e2ncia.<\/li><li>A manuten\u00e7\u00e3o \u00e9 conveniente, a estrutura da v\u00e1lvula gaveta \u00e9 simples, o anel de veda\u00e7\u00e3o geralmente est\u00e1 ativo e a desmontagem e substitui\u00e7\u00e3o s\u00e3o mais convenientes.<\/li><li>Em totalmente aberto ou totalmente fechado, a comporta e a superf\u00edcie de veda\u00e7\u00e3o da sede da v\u00e1lvula e o isolamento do meio, atrav\u00e9s do meio, n\u00e3o causar\u00e3o a eros\u00e3o da superf\u00edcie de veda\u00e7\u00e3o da v\u00e1lvula.<\/li><li>Uma ampla gama de aplica\u00e7\u00f5es, di\u00e2metros de pequenos a alguns mil\u00edmetros, grandes a alguns metros e de alto v\u00e1cuo a alta press\u00e3o podem ser aplicadas. Rota\u00e7\u00e3o da bola 90 graus, na entrada a sa\u00edda deve apresentar toda a superf\u00edcie esf\u00e9rica, cortando assim o fluxo.<\/li><\/ol>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-when-using-electric-globe-valve-the-following-7-points-should-be-noted\">Ao usar a v\u00e1lvula globo el\u00e9trica, os seguintes 7 pontos devem ser observados:<\/h2>\n\n\n\n<ol class=\"wp-block-list\"><li>Quando o gasoduto \u00e9 usado pela primeira vez, h\u00e1 muita sujeira no interior. A v\u00e1lvula de bloqueio pode ser ligeiramente aberta, o fluxo de alta velocidade do meio pode ser usado para elimin\u00e1-lo e, em seguida, pode ser fechado suavemente (n\u00e3o fechado rapidamente ou bem fechado para evitar que as impurezas residuais danifiquem a superf\u00edcie de veda\u00e7\u00e3o). A v\u00e1lvula de corte el\u00e9trico \u00e9 colocada novamente em opera\u00e7\u00e3o normal.<\/li><li>A v\u00e1lvula globo el\u00e9trica deve ser aberta antes da verifica\u00e7\u00e3o de vazamento para determinar se n\u00e3o h\u00e1 defeito na v\u00e1lvula de vazamento ou se a caixa de empanque n\u00e3o tem defeito de vazamento.<\/li><li>Quando a v\u00e1lvula de corte el\u00e9trica estiver totalmente aberta, o volante deve ser invertido um pouco, para que as roscas entrem bem apertadas, para n\u00e3o perder danos.<\/li><li>V\u00e1lvula de corte el\u00e9trica normalmente aberta, a superf\u00edcie de veda\u00e7\u00e3o pode estar com sujeira pegajosa, fechada quando tamb\u00e9m deseja usar o m\u00e9todo acima para lavar e limpar e, em seguida, fechada formalmente.<\/li><li>Se o volante, manuseado danificado ou perdido, deve ser conclu\u00eddo imediatamente, n\u00e3o podendo ser substitu\u00eddo por uma placa manual flex\u00edvel, de forma a evitar danos ao esquadro da haste, a abertura e o fechamento n\u00e3o s\u00e3o bons, resultando em acidentes na produ\u00e7\u00e3o.<\/li><li>Alguns meios, na v\u00e1lvula globo el\u00e9trica, fecham ap\u00f3s o resfriamento, para que a contra\u00e7\u00e3o da v\u00e1lvula, o operador da V\u00e1lvula Globo El\u00e9trica deve ser fechado novamente em momento apropriado para que a superf\u00edcie de veda\u00e7\u00e3o n\u00e3o deixe fenda, caso contr\u00e1rio, o meio de o fluxo de alta velocidade da fenda, \u00e9 f\u00e1cil de superf\u00edcie de veda\u00e7\u00e3o de eros\u00e3o.<\/li><li>Quando uma v\u00e1lvula globo el\u00e9trica \u00e9 usada em uma tubula\u00e7\u00e3o de vapor de m\u00e9dia press\u00e3o, o condensado deve ser removido antes da abertura, ent\u00e3o o pr\u00e9-aquecimento do vapor \u00e9 realizado e a press\u00e3o de pr\u00e9-aquecimento \u00e9 mantida entre 0,2 MPA e 0,3 MPA O objetivo \u00e9 evitar mudan\u00e7as bruscas de temperatura e a press\u00e3o causada por danos na veda\u00e7\u00e3o, est\u00e1vel em um determinado estado, pode ser ajustada ao n\u00edvel de press\u00e3o necess\u00e1rio.<\/li><\/ol>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">Etiquetas relacionadas :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/\">V\u00e1lvula ZECO<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/globe-valve\/\">Fabricante de v\u00e1lvula globo - V\u00e1rios tipos de v\u00e1lvula globo<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/gate-valve\/\">Fabricante de v\u00e1lvula gaveta - v\u00e1rios tipos de v\u00e1lvula gaveta<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/ball-valve\/\">Fabricante de v\u00e1lvula esf\u00e9rica - V\u00e1rios tipos de v\u00e1lvula esf\u00e9rica<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/butterfly-valve\/\">Fabricante de v\u00e1lvula borboleta - v\u00e1rios tipos de v\u00e1lvula borboleta<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/balancing-valve\/\">V\u00e1lvula de balanceamento \u2013 V\u00e1lvula HVAC<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/pt\/categoria-do-produto\/check-valve\/\">Fabricante de v\u00e1lvula de reten\u00e7\u00e3o \u2013 V\u00e1rios tipos de v\u00e1lvula de reten\u00e7\u00e3o<\/a>\n\n<\/div>\n\n\n<p><\/p>\n<p><!-- wam:article --><\/p>\n<p>Dez artigos antes e depois<\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-working-principle-of-fireproof-valve-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 Princ\u00edpio de funcionamento da v\u00e1lvula \u00e0 prova de fogo | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-safety-requirements-for-safety-valves-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 Requisitos de seguran\u00e7a para v\u00e1lvulas de seguran\u00e7a | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-what-is-the-difference-between-hard-sealing-and-soft-sealing-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 Qual \u00e9 a diferen\u00e7a entre veda\u00e7\u00e3o dura e veda\u00e7\u00e3o suave? | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-what-valves-are-used-for-air-water-hvac-system-api-approved-valve-manufacturer.html\/\">Not\u00edcias - Quais v\u00e1lvulas s\u00e3o usadas para sistemas HVAC de ar e \u00e1gua? | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-10-points-about-principle-and-attention-of-valve-pressure-test-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 10 pontos sobre princ\u00edpio e aten\u00e7\u00e3o no teste de press\u00e3o da v\u00e1lvula | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-6-performance-indexes-for-determining-the-quality-of-sealing-materials-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 6 \u00cdndices de Desempenho para Determinar a Qualidade de Materiais de Veda\u00e7\u00e3o | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-selection-guide-of-solenoid-valve-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 Guia de Sele\u00e7\u00e3o de V\u00e1lvula Solen\u00f3ide | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-3-points-should-be-noted-when-selecting-solenoid-valves-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 3 pontos devem ser observados ao selecionar v\u00e1lvulas solen\u00f3ides | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-8-points-about-installing-the-pneumatic-actuator-valve-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 8 pontos sobre a instala\u00e7\u00e3o da v\u00e1lvula do atuador pneum\u00e1tico | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><a href=\"https:\/\/zecovalve.com\/pt\/news-how-to-install-the-valve-in-industrial-water-chiller-system-api-approved-valve-manufacturer.html\/\">Not\u00edcias \u2013 Como instalar a v\u00e1lvula no sistema de resfriamento de \u00e1gua industrial? | Fabricante de v\u00e1lvula aprovada pela API<\/a><\/p>\n<p><!-- \/wam:article --><\/p>","protected":false},"excerpt":{"rendered":"<p>Com as mais altas classifica\u00e7\u00f5es de press\u00e3o de fechamento, modelos rosqueados ou flangeados e op\u00e7\u00f5es de acabamento em ferro, lat\u00e3o ou a\u00e7o inoxid\u00e1vel \u2013 procure a Schneider\u2026 <a title=\"Princ\u00edpio de funcionamento da v\u00e1lvula globo el\u00e9trica e do atuador el\u00e9trico\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/pt\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\" aria-label=\"Mais em Princ\u00edpio de funcionamento da v\u00e1lvula globo el\u00e9trica e do atuador el\u00e9trico\">Ler mais<\/a><\/p>","protected":false},"author":2,"featured_media":17036,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[3575,2221,3577,3578],"class_list":["post-8523","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-electric-actuator-working-principle","tag-electric-globe-valve","tag-electric-globe-valve-factory","tag-electric-globe-valve-manufacturers","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/two-way-globe-valve.jpg",330,300,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/pt\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":3575,"name":"electric actuator working principle","slug":"electric-actuator-working-principle","term_group":0,"term_taxonomy_id":3575,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":2221,"name":"electric globe valve","slug":"electric-globe-valve","term_group":0,"term_taxonomy_id":2221,"taxonomy":"post_tag","description":"","parent":0,"count":2,"filter":"raw"},{"term_id":3577,"name":"electric globe valve factory","slug":"electric-globe-valve-factory","term_group":0,"term_taxonomy_id":3577,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3578,"name":"electric globe valve manufacturers","slug":"electric-globe-valve-manufacturers","term_group":0,"term_taxonomy_id":3578,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":3575,"label":"electric actuator working principle"},{"value":2221,"label":"electric globe valve"},{"value":3577,"label":"electric globe valve factory"},{"value":3578,"label":"electric globe valve manufacturers"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Electric Globe Valve &amp; Electric Actuator Working Principle | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/pt\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\" \/>\n<meta property=\"og:locale\" content=\"pt_PT\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Electric Globe Valve &amp; Electric Actuator Working Principle | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"With the highest close-off pressure ratings, threaded or flanged models, and iron, brass, or stainless steel trim options \u2013 look to Schneider ... Ler mais\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/pt\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-30T07:23:26+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-13T11:28:09+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/two-way-globe-valve.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"330\" \/>\n\t<meta property=\"og:image:height\" content=\"300\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Escrito por\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tempo estimado de leitura\">\n\t<meta name=\"twitter:data2\" content=\"4 minutos\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"pt-PT\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html#primaryimage\",\"inLanguage\":\"pt-PT\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/two-way-globe-valve.jpg\",\"width\":330,\"height\":300,\"caption\":\"Two Way Globe Valve\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\",\"name\":\"Electric Globe Valve & Electric Actuator Working Principle | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html#primaryimage\"},\"datePublished\":\"2021-12-30T07:23:26+00:00\",\"dateModified\":\"2022-08-13T11:28:09+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html#breadcrumb\"},\"inLanguage\":\"pt-PT\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\",\"url\":\"https:\/\/zecovalve.com\/news-working-principle-of-electric-globe-valve-api-approved-valve-manufacturer.html\",\"name\":\"Electric Globe Valve &#038; Electric Actuator Working Principle\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/posts\/8523","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/comments?post=8523"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/posts\/8523\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/media\/17036"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/media?parent=8523"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/categories?post=8523"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/pt\/wp-json\/wp\/v2\/tags?post=8523"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}