{"id":16585,"date":"2022-06-22T05:50:52","date_gmt":"2022-06-22T05:50:52","guid":{"rendered":"https:\/\/zecovalve.com\/?p=16585"},"modified":"2022-06-22T05:51:51","modified_gmt":"2022-06-22T05:51:51","slug":"maintenance-of-ball-valve","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/tr\/maintenance-of-ball-valve.html","title":{"rendered":"K\u00fcresel Vanan\u0131n Bak\u0131m\u0131"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"h-1-check-that-the-ball-valve-is-in-full-open-position\"><strong>1\u3001K\u00fcresel vanan\u0131n tam a\u00e7\u0131k konumda olup olmad\u0131\u011f\u0131n\u0131 kontrol edin<\/strong><\/h2>\n\n\n\n<p>Gres enjeksiyonundan sonra, valf bilyesinin \u00e7ap\u0131n\u0131n valf yuvas\u0131n\u0131n i\u00e7 b\u00f6lmesinin d\u00fczlemiyle ayn\u0131 hizada olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. Herhangi bir fark varsa, akt\u00fcat\u00f6r \u00fczerindeki a\u00e7\u0131k limit civatas\u0131n\u0131 ayarlayarak a\u00e7\u0131kl\u0131\u011f\u0131n sa\u011fland\u0131\u011f\u0131ndan emin olun.&nbsp;<a href=\"https:\/\/zecovalve.com\/tr\/\" target=\"_blank\" rel=\"noreferrer noopener\">uluslararas\u0131 vana<\/a>&nbsp;tamamen a\u00e7\u0131kt\u0131r. Aksi halde vana monte edildikten sonra vanan\u0131n tamamen a\u00e7\u0131k olup olmad\u0131\u011f\u0131na karar vermek m\u00fcmk\u00fcn de\u011fildir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>2\u3001Vana gresle dolam\u0131yor<\/strong><\/h2>\n\n\n\n<p>\u2474Gres enjeksiyon i\u015flemi ger\u00e7ekle\u015ftirilirken valf milindeki (g\u00f6vde) s\u0131zd\u0131rmazl\u0131k bas\u0131nc\u0131 20,68mpa&#039;y\u0131 a\u015fmamal\u0131d\u0131r. Bas\u0131n\u00e7 a\u015f\u0131ld\u0131\u011f\u0131nda gres tabancas\u0131nda ar\u0131za olup olmad\u0131\u011f\u0131 kontrol edilmeli ve gres enjeksiyon tabancas\u0131n\u0131n gres \u00e7\u0131k\u0131\u015f\u0131ndaki \u00e7\u0131k\u0131\u015f valfi a\u00e7\u0131lmal\u0131d\u0131r.<\/p>\n\n\n\n<p>\u2475Valf gres tabancas\u0131 sorunsuzsa, l\u00fctfen gres a\u011fz\u0131n\u0131n t\u0131kal\u0131 olup olmad\u0131\u011f\u0131n\u0131 kontrol edin, yani gres memesini yava\u015f\u00e7a \u00e7evirin ve gres tabancas\u0131n\u0131n gres \u00e7\u0131k\u0131\u015f deli\u011fine tak\u0131n. Gres noz\u00fcl\u00fcne gres enjeksiyonu yaparak, gres enjeksiyon nozulunun gres \u00fcretip \u00fcretmedi\u011fini g\u00f6zlemleyin. Gres enjeksiyon noz\u00fcl\u00fc gres \u00fcretebiliyorsa, gres enjeksiyon nozulunun a\u015fa\u011f\u0131s\u0131ndaki gres enjeksiyon deli\u011finde bulunan tek y\u00f6nl\u00fc valfin kontrol edilmesi ve inceleme amac\u0131yla \u00f6zel aletler kullan\u0131larak vidalanmas\u0131 gerekir.&nbsp;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>3\u3001Ya\u011f enjeksiyon deli\u011finden e\u015fit olmayan ya\u011f \u00e7\u0131k\u0131\u015f\u0131<\/strong><\/h2>\n\n\n\n<p>Bazen valf yata\u011f\u0131 contas\u0131ndaki valften \u00f6nce ve sonra boru t\u0131kanmas\u0131, yuva ya\u011flama delikleri d\u00fczensiz ya\u011f veya ya\u011fs\u0131z fenomeni ortaya \u00e7\u0131kar, bu noktada valf tamamen a\u00e7\u0131kken 15 \u00b0 ~ 25 \u00b0 yuva gres deliklerinden sonra yak\u0131n g\u00f6zlem yap\u0131l\u0131r. ve g\u00f6zlemi ya\u011flamak i\u00e7in hafif\u00e7e p\u00fcr\u00fczs\u00fcz, yumu\u015fak aletler. Yuva contas\u0131na zarar vermemek i\u00e7in, d\u00f6n\u00fc\u015f i\u015fleminde valf bilyas\u0131n\u0131n ya\u011flanmamas\u0131na \u00f6zellikle dikkat edilmelidir. Genel olarak her iki tarafta&nbsp;<a href=\"https:\/\/zecovalve.com\/tr\/products\/ball-valve\/\" target=\"_blank\" rel=\"noreferrer noopener\">k\u00fcresel vana<\/a>&nbsp;4 gres enjeksiyon nozullu koltuk daha d\u00fczg\u00fcnd\u00fcr, 2 gres enjeksiyon noz\u00fcl\u00fc ise nispeten d\u00fczensizdir.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">\u0130lgili Etiketler :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/\">ZECO Valf<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/gate-valve-problems.html\/\">S\u00fcrg\u00fcl\u00fc Vana Onar\u0131m\u0131<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/difference-between-gate-valves-and-ball-valves.html\/\">S\u00fcrg\u00fcl\u00fc Vana vs K\u00fcresel Vana<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/what-is-an-axial-flow-silent-check-valve.html\/\">Eksenel \u00c7ekvalf Nedir<\/a>\n\n<\/div>\n\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/the-function-of-globe-valve-in-pipeline-system.html\/\">Glob Vanalar Nedir?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/urun\/manual-gate-valve\/\">Manuel Kumandal\u0131 S\u00fcrg\u00fcl\u00fc Vana \u00dcreticisi<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/difference-between-gate-valve-and-butterfly-valve.html\/\">S\u00fcrg\u00fcl\u00fc Vana ve Kelebek Vana Aras\u0131ndaki Fark<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/china-gate-valves-suppliersnon-rising-stem-gate-valvesks-gate-valves.html\/\">S\u00fcrg\u00fcl\u00fc Vana Nedir?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/tag\/shanghai-pressure-reducing-valve-factory\/\">\u015eangay Bas\u0131n\u00e7 D\u00fc\u015f\u00fcr\u00fcc\u00fc Vana Fabrikas\u0131<\/a>\n\n<\/div>","protected":false},"excerpt":{"rendered":"<p>1\u3001K\u00fcresel vanan\u0131n tam a\u00e7\u0131k konumda olup olmad\u0131\u011f\u0131n\u0131 kontrol edin. Gres enjeksiyonundan sonra, vana bilyas\u0131n\u0131n \u00e7ap\u0131n\u0131n \u015fu \u015fekilde olup olmad\u0131\u011f\u0131n\u0131 kontrol edin: <a title=\"K\u00fcresel Vanan\u0131n Bak\u0131m\u0131\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/tr\/maintenance-of-ball-valve.html\" aria-label=\"K\u00fcresel Vanan\u0131n Bak\u0131m\u0131 Hakk\u0131nda Daha Fazla Bilgi\">Daha fazla bilgi edinin<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1927],"tags":[2204,2327],"class_list":["post-16585","post","type-post","status-publish","format-standard","hentry","category-ball-valve","tag-ball-valves","tag-maintenance-of-ball-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/tr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1927,"name":"Ball Valve","slug":"ball-valve","term_group":0,"term_taxonomy_id":1927,"taxonomy":"category","description":"Ball Valve Description","parent":0,"count":82,"filter":"raw","cat_ID":1927,"category_count":82,"category_description":"Ball Valve Description","cat_name":"Ball Valve","category_nicename":"ball-valve","category_parent":0}],"tag_info":[{"term_id":2204,"name":"Ball Valves","slug":"ball-valves","term_group":0,"term_taxonomy_id":2204,"taxonomy":"post_tag","description":"","parent":0,"count":38,"filter":"raw"},{"term_id":2327,"name":"maintenance of ball valve","slug":"maintenance-of-ball-valve","term_group":0,"term_taxonomy_id":2327,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1927,"label":"Ball Valve"}],"post_tag":[{"value":2204,"label":"Ball Valves"},{"value":2327,"label":"maintenance of ball valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Maintenance of Ball Valve - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/tr\/maintenance-of-ball-valve.html\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Maintenance of Ball Valve - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"1\u3001Check that the ball valve is in full open position After grease injection, check whether the diameter of the valve ball is ... Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/tr\/maintenance-of-ball-valve.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-22T05:50:52+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-06-22T05:51:51+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\">\n\t<meta name=\"twitter:data2\" content=\"1 dakika\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"tr\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html\",\"name\":\"Maintenance of Ball Valve - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"datePublished\":\"2022-06-22T05:50:52+00:00\",\"dateModified\":\"2022-06-22T05:51:51+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html\",\"url\":\"https:\/\/zecovalve.com\/maintenance-of-ball-valve.html\",\"name\":\"Maintenance of Ball Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/16585","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/comments?post=16585"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/16585\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/media?parent=16585"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/categories?post=16585"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/tags?post=16585"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}