{"id":17317,"date":"2022-06-27T13:23:19","date_gmt":"2022-06-27T13:23:19","guid":{"rendered":"https:\/\/zecovalve.com\/?p=17317"},"modified":"2022-08-03T16:11:59","modified_gmt":"2022-08-03T16:11:59","slug":"zeco-valve-test-system","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/tr\/zeco-valve-test-system.html","title":{"rendered":"Zeco Valf Test Sistemi"},"content":{"rendered":"<h2 class=\"wp-block-heading\" id=\"h-1-valve-flow-characteristic-test\">1\u3001Vana Ak\u0131\u015f Karakteristik Testi<\/h2>\n\n\n\n<p>Test vanas\u0131n\u0131 boyutuna g\u00f6re boru hatt\u0131n\u0131n kar\u015f\u0131l\u0131k gelen konumuna tak\u0131n, frekans d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fcy\u00fc belirtilen orana g\u00f6re frekans art\u0131\u015f\u0131n\u0131 yapmak i\u00e7in \u00e7al\u0131\u015ft\u0131r\u0131n, pompa h\u0131z\u0131 artar, vanan\u0131n her iki taraf\u0131ndaki bas\u0131n\u00e7 fark\u0131 buna g\u00f6re de\u011fi\u015fir ve kar\u015f\u0131l\u0131k gelen ak\u0131\u015f de\u011feri ayn\u0131 anda. Vanan\u0131n iki taraf\u0131 aras\u0131ndaki bas\u0131n\u00e7 fark\u0131 maksimum bas\u0131n\u00e7 fark\u0131na ula\u015ft\u0131\u011f\u0131nda veya \u00e7al\u0131\u015fma frekans\u0131 50HZ&#039;ye ula\u015ft\u0131\u011f\u0131nda frekans d\u00f6n\u00fc\u015ft\u00fcr\u00fcc\u00fc otomatik olarak yava\u015flar ve durur. Deneyi tamamlamak i\u00e7in ak\u0131\u015f sens\u00f6r\u00fc ve fark bas\u0131n\u00e7 sens\u00f6r\u00fcn\u00fcn verileri kaydedildi ve fark bas\u0131nc\u0131 ak\u0131\u015f karakteristik e\u011frisi \u00e7izildi. \u0130NC\u0130R. \u015eekil 1, ak\u0131\u015f dengeleme vanas\u0131n\u0131n ak\u0131\u015f karakteristik e\u011frisinin test sonu\u00e7lar\u0131n\u0131 g\u00f6stermektedir.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"300\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png\" alt=\"\" class=\"wp-image-17318\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3-300x225.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<p>\u015eekil 1: Ak\u0131\u015f dengeleme valfi ak\u0131\u015f-bas\u0131n\u00e7 fark\u0131 e\u011frisi<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-2-valve-opening-characteristic-test\">2\u3001Vana A\u00e7ma Karakteristi\u011fi Testi<\/h2>\n\n\n\n<p>Akt\u00fcat\u00f6rl\u00fc reg\u00fclat\u00f6r\u00fc boru hatt\u0131na monte edin, ak\u0131\u015f\u0131 ayarlamak i\u00e7in vanan\u0131n a\u00e7\u0131kl\u0131\u011f\u0131n\u0131 ayarlay\u0131n ve a\u00e7\u0131k ak\u0131\u015f karakteristik e\u011frisini elde etmek i\u00e7in vanan\u0131n iki ucu aras\u0131ndaki bas\u0131n\u00e7 fark\u0131n\u0131 100kPa&#039;da kontrol edin. \u015eekil 2&#039;ye bak\u0131n\u0131z.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full\"><img loading=\"lazy\" decoding=\"async\" width=\"400\" height=\"300\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-4.png\" alt=\"\" class=\"wp-image-17319\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-4.png 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-4-300x225.png 300w\" sizes=\"auto, (max-width: 400px) 100vw, 400px\" \/><\/figure>\n\n\n\n<p>\u015eekil 2: A\u00e7\u0131k Ak\u0131\u015f E\u011frisi<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-3-valve-flow-coefficient-valve-resistance-coefficient-test\">3\u3001Vana Ak\u0131\u015f Katsay\u0131s\u0131, Valf Diren\u00e7 Katsay\u0131s\u0131 Testi<\/h2>\n\n\n\n<p>Su vanas\u0131n\u0131n iki ucu aras\u0131ndaki bas\u0131n\u00e7 fark\u0131 100kPa olarak kontrol edilir ve bu s\u0131rada vanan\u0131n debisi \u00f6l\u00e7\u00fcl\u00fcr. Ak\u0131\u015f katsay\u0131s\u0131 form\u00fcl (1) kullan\u0131larak elde edilebilir ve diren\u00e7 katsay\u0131s\u0131 form\u00fcl (2) ile hesaplanabilir; burada V, form\u00fcl (3) ile hesaplanan vana boru hatt\u0131n\u0131n ak\u0131\u015f h\u0131z\u0131d\u0131r ve D nominal \u00e7apt\u0131r. vanan\u0131n. Yukar\u0131daki prosed\u00fcr test se\u00e7ene\u011fine girdikten sonra rapor bilgisayar taraf\u0131ndan otomatik olarak olu\u015fturulur.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-4-pressure-regulating-test-of-pressure-reducing-valve-and-pressure-differential-valve\">4\u3001Bas\u0131n\u00e7 D\u00fc\u015f\u00fcr\u00fcc\u00fc Vana ve Bas\u0131n\u00e7 Diferansiyel Vanas\u0131n\u0131n Bas\u0131n\u00e7 D\u00fczenleme Testi<\/h2>\n\n\n\n<p>Test tezgah\u0131, \u00e7\u0131k\u0131\u015f bas\u0131nc\u0131n\u0131 ve ak\u0131\u015f\u0131n\u0131 ve giri\u015f bas\u0131nc\u0131 e\u011frisini test etmek i\u00e7in kullan\u0131labilir. <a href=\"https:\/\/zecovalve.com\/tr\/water-pressure-reducing-valve-manufacturer-zeco-valve.html\/\" data-internallinksmanager029f6b8e52c=\"8\" title=\"Bas\u0131n\u00e7 D\u00fc\u015f\u00fcr\u00fcc\u00fc Valf\" target=\"_blank\" rel=\"noopener\">bas\u0131n\u00e7 d\u00fc\u015f\u00fcr\u00fcc\u00fc valf<\/a>Diferansiyel bas\u0131n\u00e7 kontrol vanas\u0131n\u0131n iki ucu aras\u0131ndaki bas\u0131n\u00e7 fark\u0131 ile ak\u0131\u015f ve giri\u015f bas\u0131nc\u0131n\u0131n de\u011fi\u015fim e\u011frisi deney tablosu kullan\u0131larak \u00f6l\u00e7\u00fclebilir.<\/p>","protected":false},"excerpt":{"rendered":"<p>1\u3001Vana Ak\u0131\u015f Karakteristik Testi Test valfini boru hatt\u0131n\u0131n boyutuna g\u00f6re kar\u015f\u0131l\u0131k gelen konumuna tak\u0131n, frekans\u0131 ba\u015flat\u0131n\u2026 <a title=\"Zeco Valf Test Sistemi\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/tr\/zeco-valve-test-system.html\" aria-label=\"Zeco Valf Test Sistemi hakk\u0131nda daha fazlas\u0131\">Daha fazla bilgi edinin<\/a><\/p>","protected":false},"author":2,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[153,40,5],"class_list":["post-17317","post","type-post","status-publish","format-standard","hentry","category-uncategorized","tag-flow","tag-pressure","tag-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":false,"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/tr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":153,"name":"flow","slug":"flow","term_group":0,"term_taxonomy_id":153,"taxonomy":"post_tag","description":"","parent":0,"count":25,"filter":"raw"},{"term_id":40,"name":"pressure","slug":"pressure","term_group":0,"term_taxonomy_id":40,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":5,"name":"valve","slug":"valve","term_group":0,"term_taxonomy_id":5,"taxonomy":"post_tag","description":"","parent":0,"count":116,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":153,"label":"flow"},{"value":40,"label":"pressure"},{"value":5,"label":"valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Zeco Valve Test System - ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/tr\/zeco-valve-test-system.html\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Zeco Valve Test System - ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"1\u3001Valve Flow Characteristic Test Install the test valve in the corresponding position of the pipeline according to its size, start the frequency ... Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/tr\/zeco-valve-test-system.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2022-06-27T13:23:19+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-08-03T16:11:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\">\n\t<meta name=\"twitter:data2\" content=\"1 dakika\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"tr\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#primaryimage\",\"inLanguage\":\"tr\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/figure-3.png\",\"width\":400,\"height\":300},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\",\"name\":\"Zeco Valve Test System - ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#primaryimage\"},\"datePublished\":\"2022-06-27T13:23:19+00:00\",\"dateModified\":\"2022-08-03T16:11:59+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\",\"url\":\"https:\/\/zecovalve.com\/zeco-valve-test-system.html\",\"name\":\"Zeco Valve Test System\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/17317","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/comments?post=17317"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/17317\/revisions"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/media?parent=17317"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/categories?post=17317"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/tags?post=17317"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}