{"id":8930,"date":"2021-12-30T08:01:27","date_gmt":"2021-12-30T08:01:27","guid":{"rendered":"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html"},"modified":"2022-07-25T13:39:20","modified_gmt":"2022-07-25T13:39:20","slug":"when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/tr\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html","title":{"rendered":"API 6D K\u00fcresel Vana \u00dcreticisi \u2013 API 609 Kelebek Vana Tedarik\u00e7isi"},"content":{"rendered":"<h2 class=\"wp-block-heading\">API \u2013 Amerikan Petrol Enstit\u00fcs\u00fc (K\u00fcresel Vana Standard\u0131)<\/h2>\n\n\n\n<p>Boru hatt\u0131 vanalar\u0131 i\u00e7in API 6D Spesifikasyonu (K\u00fcresel, S\u00fcrg\u00fcl\u00fc, Fi\u015fli ve \u00c7ek Valfler)<\/p>\n\n\n\n<p>Valfler i\u00e7in yang\u0131n testi i\u00e7in API 6FA \u015eartnamesi<\/p>\n\n\n\n<p>Yumu\u015fak yatakl\u0131 \u00e7eyrek d\u00f6n\u00fc\u015fl\u00fc vanalar i\u00e7in API 607 Yang\u0131n Testi<\/p>\n\n\n\n<p>API 598 Valf muayenesi ve testi<\/p>\n\n\n\n<p>Petrol ve Do\u011fal Gaz End\u00fcstrisine y\u00f6nelik Kalite programlar\u0131 i\u00e7in API Q1 Spesifikasyonu<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">API 6D K\u00fcresel Vana Nedir?<\/h2>\n\n\n\n<p>API 6D k\u00fcresel vanalar g\u00fcvenilirlik ve y\u00fcksek performans i\u00e7in tasarlanm\u0131\u015ft\u0131r ve enerji, petrol ve gaz ile petrokimya end\u00fcstrilerindeki kapatma uygulamalar\u0131 i\u00e7in m\u00fckemmel bir se\u00e7imdir. API 6D y\u00fczer k\u00fcresel vana ve API 6D muyluya monteli k\u00fcresel vanalar mevcuttur. K\u00fcresel vana API 6D, API 6D spesifikasyonlar\u0131n\u0131n tasar\u0131m, \u00fcretim ve testlerini tam olarak kar\u015f\u0131lar.<\/p>\n\n\n\n<p>ZECO Valve, end\u00fcstrinin en kat\u0131 spesifikasyonlar\u0131n\u0131 kar\u015f\u0131lamak \u00fczere tasarlanm\u0131\u015f 2\u201d-8\u201d API 6D y\u00fczer k\u00fcresel vanalar sunmaktad\u0131r. \u00dcr\u00fcnlerimiz ANSI S\u0131n\u0131flar\u0131 150-1500, malzeme s\u0131n\u0131f\u0131 WCB d\u00f6kme karbon \u00e7eli\u011fi ve A105 d\u00f6vme \u00e7eli\u011fi i\u00e7erir.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-1024x1024.jpg\" alt=\"\" class=\"wp-image-19547\" width=\"512\" height=\"512\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-1024x1024.jpg 1024w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-300x300.jpg 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-150x150.jpg 150w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-768x768.jpg 768w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-1536x1536.jpg 1536w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-2048x2048.jpg 2048w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-400x400.jpg 400w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-600x600.jpg 600w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/07\/3-piece-stainless-steel-ball-valve-2-100x100.jpg 100w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n<h3 class=\"wp-block-heading\">API 6D Y\u00fczer K\u00fcresel Vana<\/h3>\n\n\n\n<p>Petrol ve Petrol ve Gaz End\u00fcstrisine y\u00f6nelik boru hatt\u0131 ve boru sistemlerinde uygulamaya y\u00f6nelik API 6D Y\u00dcZER K\u00dcRESEL VANALAR.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>BOYUT ARALI\u011eI<\/td><td>2\u201d \u2013 8\u201d<\/td><\/tr><tr><td>BASIN\u00c7 ARALI\u011eI<\/td><td>150 ANSI bas\u0131n\u00e7 s\u0131n\u0131f\u0131ndan 1500 ANSI bas\u0131n\u00e7 s\u0131n\u0131f\u0131na<\/td><\/tr><tr><td>L\u0130MAN BOYUTLARI<\/td><td>\u0130ki par\u00e7al\u0131 tam ba\u011flant\u0131 noktas\u0131 tasar\u0131m\u0131, \u0130ki par\u00e7al\u0131 azalt\u0131lm\u0131\u015f ba\u011flant\u0131 noktas\u0131 tasar\u0131m\u0131<\/td><\/tr><tr><td>MALZEME KAL\u0130TELER\u0130<\/td><td>WCB, A105N<\/td><\/tr><tr><td>D\u00d6\u015eEME MALZEMELER\u0130<\/td><td>Top: 316 Paslanmaz \u00c7elik ve egzotik ala\u015f\u0131mlar. G\u00f6vde: ANSI 150-300# i\u00e7in 316 paslanmaz \u00e7elik, ANSI 600# i\u00e7in F51 Dubleks<\/td><\/tr><tr><td>STANDART KOLTUK MALZEMES\u0130<\/td><td>TFM1600<\/td><\/tr><tr><td>AMBALAJ VE CONTA MALZEMES\u0130<\/td><td>Grafit<\/td><\/tr><tr><td>O-R\u0130NG MALZEMES\u0130<\/td><td>HNBR 90<\/td><\/tr><tr><td>SON YAPILANDIRMALAR<\/td><td>Y\u00fckseltilmi\u015f Y\u00fcz ve RTJ<\/td><\/tr><tr><td>STANDARTLAR<\/td><td>Yang\u0131na dayan\u0131kl\u0131, CE sertifikal\u0131, NACE sertifikal\u0131<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\">API 6D Muylulu K\u00fcresel Vana<\/h3>\n\n\n\n<p>ZECO Valve, end\u00fcstrinin en kat\u0131 spesifikasyonlar\u0131n\u0131 kar\u015f\u0131lamak \u00fczere tasarlanm\u0131\u015f 2\u201d-56\u201d API 6D muylu k\u00fcresel vanalar sunmaktad\u0131r. \u00dcr\u00fcnlerimiz ANSI S\u0131n\u0131flar\u0131 150-2500, malzeme s\u0131n\u0131f\u0131 WCB d\u00f6kme karbon \u00e7eli\u011fi ve A105 d\u00f6vme \u00e7eli\u011fi i\u00e7erir.<\/p>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table><tbody><tr><td>BOYUT ARALI\u011eI<\/td><td>2\u2033 - 56\u2033<\/td><\/tr><tr><td>BASIN\u00c7 ARALI\u011eI<\/td><td>150 ANSI bas\u0131n\u00e7 s\u0131n\u0131f\u0131ndan 2500 ANSI bas\u0131n\u00e7 s\u0131n\u0131f\u0131na<\/td><\/tr><tr><td>SICAKLIK ARALI\u011eI<\/td><td>-196\u00b0C \u2013 +500\u00b0C<\/td><\/tr><tr><td>KOLTUK KA\u00c7AK ORANI<\/td><td>ISO 5208 Derece D ve A, ANSI\/FCI 70-2 S\u0131n\u0131f V ve VI<\/td><\/tr><tr><td>SON FLAN\u015e BA\u011eLANTISI<\/td><td>ASME B16.5(2&quot; ila 24&quot;), ASME B16.47 Seri A (26&quot; ve \u00fczeri)<\/td><\/tr><tr><td>KALKAN UCU<\/td><td>ASME B16.25<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">API 6D Muylu K\u00fcresel Vanan\u0131n \u00d6zellikleri<\/h2>\n\n\n\n<ul class=\"wp-block-list\"><li>API 6D&#039;ye g\u00f6re tasarlanm\u0131\u015f vanalar<\/li><li>T\u00fcm boyutlar tam veya azalt\u0131lm\u0131\u015f delik olarak mevcuttur<\/li><li>Talep \u00fczerine \u00e7ift bloklu bo\u015faltma<\/li><li>BS 6755, API 6FA ve API 607&#039;ye g\u00f6re yang\u0131na kar\u015f\u0131 g\u00fcvenli<\/li><li>Tek veya \u00e7ift pistonlu tipte valf yuvalar\u0131<\/li><li>Uygulamaya uygun elastomerik ve termoplastik s\u0131zd\u0131rmazl\u0131k malzemeleri<\/li><li>Her t\u00fcrl\u00fc akt\u00fcat\u00f6r ve aksesuarla birlikte teslim edilebilir<\/li><li>Gres enjeksiyonu ile ikincil s\u0131zd\u0131rmazl\u0131k<\/li><li>T\u00fcm ebat ve s\u0131n\u0131flarda metal-metal s\u0131zd\u0131rmazl\u0131k mevcuttur<\/li><li>Talep \u00fczerine tamamen kaynakl\u0131<\/li><li>Antistatik cihaz ve patlama \u00f6nleyici g\u00f6vde<\/li><li>Kriyojenik veya y\u00fcksek s\u0131cakl\u0131kta servis i\u00e7in \u00f6zel uygulamalar<\/li><\/ul>\n\n\n\n<h2 class=\"wp-block-heading\">API \u2013 Amerikan Petrol Enstit\u00fcs\u00fc (Kelebek Vana Standard\u0131)<\/h2>\n\n\n\n<p>API 609 Kelebek Vanalar: \u00c7ift Flan\u015fl\u0131, Lug ve Gofret tipi ve Al\u0131n Kaynakl\u0131 U\u00e7lar, Dokuzuncu Bask\u0131<\/p>\n\n\n\n<p>Kategori A \u2014 \u00dcreticinin nominal so\u011fuk \u00e7al\u0131\u015fma bas\u0131nc\u0131 (CWP) kelebek vanalar\u0131, genellikle e\u015fmerkezli disk ve yuva konfig\u00fcrasyonuna sahiptir. Kapsanan boyutlar, ASME S\u0131n\u0131f 125 veya S\u0131n\u0131f 150 flan\u015f c\u0131vatalama modellerine sahip vanalar i\u00e7in NPS 2 ila NPS 60&#039;t\u0131r.<\/p>\n\n\n\n<p>Kategori B\u2014ASME s\u0131n\u0131f\u0131 ve ofset yuvas\u0131na ve eksantrik veya e\u015fmerkezli disk konfig\u00fcrasyonuna sahip bas\u0131n\u00e7-s\u0131cakl\u0131k dereceli kelebek vanalar. Kapsanan boyutlar a\u015fa\u011f\u0131da listelenmi\u015ftir:<br>pabu\u00e7 ve levha i\u00e7in, S\u0131n\u0131f 150 ve 300: NPS 2 ila NPS 60;<br>pabu\u00e7 ve levha i\u00e7in, S\u0131n\u0131f 600: NPS 3 ila NPS 60;<br>\u00e7ift flan\u015fl\u0131 k\u0131sa ve uzun model i\u00e7in S\u0131n\u0131f 150, 300 ve 600: NPS 3 ila NPS 60;<br>al\u0131n kayna\u011f\u0131 u\u00e7lar\u0131 i\u00e7in S\u0131n\u0131f 150, 300 ve 600: NPS 3 ila 60;<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-know-about-butterfly-valve\">Kelebek Vana hakk\u0131nda bilgi sahibi olun<\/h2>\n\n\n\n<p>Kelebek vanalar su, yo\u011fu\u015fma suyu, sirk\u00fclasyon suyu, kanalizasyon, deniz suyu, hava, gaz, s\u0131v\u0131 do\u011fal gaz, kuru toz, bulama\u00e7, ka\u011f\u0131t hamuru ve ask\u0131da madde i\u00e7eren kar\u0131\u015f\u0131mlar gibi ortamlar\u0131 ta\u015f\u0131yabilir ve kontrol edebilir.<\/p>\n\n\n\n<p>Kelebek vana ak\u0131\u015f reg\u00fclasyonu i\u00e7in uygundur. Boru hatt\u0131ndaki kelebek vanan\u0131n bas\u0131n\u00e7 kayb\u0131 nispeten b\u00fcy\u00fck oldu\u011fundan, s\u00fcrg\u00fcl\u00fc vanan\u0131n yakla\u015f\u0131k \u00fc\u00e7 kat\u0131 oldu\u011fundan, kelebek vanay\u0131 se\u00e7erken bas\u0131n\u00e7 kayb\u0131n\u0131n boru hatt\u0131 sistemi \u00fczerindeki etkisi tam olarak dikkate al\u0131nmal\u0131 ve vanan\u0131n sa\u011flaml\u0131\u011f\u0131 dikkate al\u0131nmal\u0131d\u0131r. Kelebek plakan\u0131n kapal\u0131yken boru hatt\u0131 ortam\u0131n\u0131n bas\u0131nc\u0131na dayanabilece\u011fi de dikkate al\u0131nmal\u0131d\u0131r. Ayr\u0131ca esnek valf yuvas\u0131 malzemesinin y\u00fcksek s\u0131cakl\u0131klarda dayanabilece\u011fi \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131 s\u0131n\u0131rlar\u0131n\u0131 da dikkate almak gerekir. Kelebek vana yap\u0131s\u0131n\u0131n uzunlu\u011fu ve toplam y\u00fcksekli\u011fi k\u00fc\u00e7\u00fckt\u00fcr, h\u0131zl\u0131 a\u00e7\u0131l\u0131r ve kapan\u0131r ve iyi ak\u0131\u015fkan kontrol \u00f6zelliklerine sahiptir; kelebek vana yap\u0131 prensibi, b\u00fcy\u00fck \u00e7apl\u0131 vanalar\u0131n yap\u0131m\u0131 i\u00e7in en uygun olan\u0131d\u0131r. Ak\u0131\u015f kontrol\u00fc i\u00e7in kelebek vana kullan\u0131lmas\u0131 gerekti\u011finde en \u00f6nemli \u015fey, kelebek vanan\u0131n d\u00fczg\u00fcn ve verimli \u00e7al\u0131\u015fabilmesi i\u00e7in do\u011fru boyut ve tipte kelebek vanan\u0131n se\u00e7ilmesidir.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter\"><img decoding=\"async\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2021\/12\/20211230080126-61cd675622866.png\" alt=\"Kelebek Vana\" title=\"Kelebek Vana\"\/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\" id=\"h-when-is-a-butterfly-valve-used\">Kelebek Vana Ne Zaman Kullan\u0131l\u0131r?<\/h2>\n\n\n\n<p>Bir\u00e7ok \u00e7e\u015fit var <span style=\"text-decoration: underline;\"><strong>kelebek vana<\/strong><\/span>, h\u0131zl\u0131 kesme ve s\u00fcrekli ayarlamalar mevcuttur. Esas olarak s\u0131v\u0131, gaz, d\u00fc\u015f\u00fck bas\u0131n\u00e7l\u0131, geni\u015f \u00e7apl\u0131 boru hatt\u0131 i\u00e7in kullan\u0131l\u0131r. Bas\u0131n\u00e7 kayb\u0131 gereksinimleri y\u00fcksek olmad\u0131\u011f\u0131 i\u00e7in, ak\u0131\u015f reg\u00fclasyonu ihtiyac\u0131, h\u0131zl\u0131 durumlar i\u00e7in a\u00e7ma ve kapama gereksinimleri uygundur. Genellikle s\u0131cakl\u0131k 300\u00b0C&#039;nin alt\u0131ndad\u0131r, bas\u0131n\u00e7 40 kg&#039;\u0131n alt\u0131ndad\u0131r, ortam genellikle su ve gaz i\u00e7in kullan\u0131l\u0131r, ortam gereksinimleri y\u00fcksek de\u011fildir, gran\u00fcl ortam da kullan\u0131labilir.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-several-working-conditions-of-the-applicable-butterfly-valve\">Uygulanabilir kelebek vanan\u0131n \u00e7e\u015fitli \u00e7al\u0131\u015fma ko\u015fullar\u0131<\/h2>\n\n\n\n<p>1. Genellikle k\u0131sma, d\u00fczenleme kontrol\u00fc ve bulama\u00e7 ortamlar\u0131nda k\u0131sa yap\u0131 uzunlu\u011fu ve h\u0131zl\u0131 a\u00e7\u0131lma ve kapanma h\u0131z\u0131 (1\/4 tur) gereklidir. D\u00fc\u015f\u00fck bas\u0131n\u00e7ta kesme (k\u00fc\u00e7\u00fck fark bas\u0131nc\u0131), kelebek vana \u00f6nerilir.<\/p>\n\n\n\n<p>2. \u00d6zel \u00e7al\u0131\u015fma ko\u015fullar\u0131nda k\u0131sma ayar\u0131 veya s\u0131k\u0131 s\u0131zd\u0131rmazl\u0131k veya ciddi a\u015f\u0131nma, d\u00fc\u015f\u00fck s\u0131cakl\u0131k (derin so\u011fuk) ve kelebek vana kullan\u0131l\u0131rken di\u011fer \u00e7al\u0131\u015fma ko\u015fullar\u0131nda, \u00fc\u00e7 eksantrik veya \u00e7ift eksantrik \u00f6zel d\u00fczenleme cihaz\u0131 ile \u00f6zel tasar\u0131m metal conta kullan\u0131lmas\u0131 gerekir kelebek vana.<\/p>\n\n\n\n<p>3. Kelebek vana, \u00e7ift konumlu ayar, girintili kanal, d\u00fc\u015f\u00fck g\u00fcr\u00fclt\u00fc, kavitasyon ve kavitasyon, atmosfere k\u00fc\u00e7\u00fck s\u0131z\u0131nt\u0131 ve a\u015f\u0131nd\u0131r\u0131c\u0131 ortamlarda kullan\u0131labilir.<\/p>\n\n\n\n<p>4. Yumu\u015fak contal\u0131 eksantrik kelebek vana, metalurji, hafif sanayi, elektrik enerjisi, gaz boru hatt\u0131n\u0131n petrokimya sistemi ve su yolu vb. alanlarda yayg\u0131n olarak kullan\u0131lan havaland\u0131rma ve toz giderme boru hatt\u0131n\u0131n \u00e7ift y\u00f6nl\u00fc a\u00e7\u0131l\u0131p kapanmas\u0131 ve ayarlanmas\u0131 i\u00e7in uygundur.<\/p>\n\n\n\n<p>5. Orta Hat <span style=\"text-decoration: underline;\"><strong>kelebek vana<\/strong><\/span>&nbsp;tatl\u0131 su, kanalizasyon, deniz suyu, tuzlu su, buhar, do\u011fal gaz, g\u0131da, ila\u00e7, ya\u011f ve \u00e7e\u015fitli asitler ve alkaliler ile tam s\u0131zd\u0131rmazl\u0131k, gaz testinde s\u0131f\u0131r s\u0131z\u0131nt\u0131, y\u00fcksek \u00f6m\u00fcr beklentisi ve \u00e7al\u0131\u015fma s\u0131cakl\u0131\u011f\u0131 gerektiren di\u011fer boru hatlar\u0131 i\u00e7in uygundur. -10\u00b0C ila 150\u00b0C.<\/p>\n\n\n\n<p>5. Metalden metale y\u00fcz contal\u0131 \u00fc\u00e7l\u00fc eksantrik kelebek vana, b\u00fcy\u00fck bir bas\u0131n\u00e7 sal\u0131n\u0131ml\u0131 adsorpsiyon (PSA) gaz ay\u0131rma cihaz\u0131 olarak kullan\u0131lmas\u0131n\u0131n yan\u0131 s\u0131ra, petrol, petrokimya, kimya, metalurji, elektrik enerjisi ve di\u011fer alanlarda yayg\u0131n olarak kullan\u0131labilir. program kontrol vanas\u0131d\u0131r ve s\u00fcrg\u00fcl\u00fc vanalara ve k\u00fcresel vanalara iyi bir alternatiftir.<\/p>\n\n\n\n<p>6. Metalden metale hat contal\u0131 \u00e7ift eksantrik kelebek vana, d\u00fczenleme ve k\u0131sma cihaz\u0131 olarak kentsel \u0131s\u0131tma, gaz temini, su temini ve di\u011fer gaz, ya\u011f, asit ve alkali boru hatlar\u0131 i\u00e7in uygundur.<\/p>\n\n\n\n<p>7. Genellikle k\u0131sma, d\u00fczenleme kontrol\u00fc ve bulama\u00e7 ortamlar\u0131nda yap\u0131n\u0131n uzunlu\u011funun k\u0131sa ve a\u00e7\u0131lma ve kapanma h\u0131z\u0131n\u0131n h\u0131zl\u0131 (1\/4 tur) olmas\u0131 gerekir. D\u00fc\u015f\u00fck bas\u0131n\u00e7ta kesme (k\u00fc\u00e7\u00fck fark bas\u0131nc\u0131), kelebek vana tavsiye edilir.<\/p>\n\n\n\n<p>\u0130pucu: S\u0131zd\u0131rmaz bir kelebek vana olarak, ancak sentetik kau\u00e7u\u011fun ortaya \u00e7\u0131kmas\u0131ndan sonra h\u0131zl\u0131 bir geli\u015fme sa\u011flad\u0131, bu nedenle yeni bir kesme vanas\u0131 t\u00fcr\u00fcd\u00fcr. \u00dclkemizde 1980&#039;li y\u0131llara kadar kelebek vanalar a\u011f\u0131rl\u0131kl\u0131 olarak sentetik kau\u00e7uk yatakl\u0131 al\u00e7ak bas\u0131n\u00e7 vanalar\u0131 olarak i\u015flev g\u00f6r\u00fcrken, 1990&#039;l\u0131 y\u0131llardan itibaren yurt d\u0131\u015f\u0131 ile artan al\u0131\u015fveri\u015fler nedeniyle sert contal\u0131 (metal contal\u0131) kelebek vanalar h\u0131zla geli\u015fmeye ba\u015flam\u0131\u015ft\u0131r. \u015eu anda, orta bas\u0131n\u00e7l\u0131 metal s\u0131zd\u0131rmaz kelebek vanalar\u0131 istikrarl\u0131 bir \u015fekilde \u00fcretebilen birka\u00e7 vana fabrikas\u0131 bulunmaktad\u0131r ve bu da kelebek vanalar\u0131n sahada daha yayg\u0131n olarak kullan\u0131lmas\u0131n\u0131 sa\u011flamaktad\u0131r.<\/p>\n\n\n\n<p>Biz <span style=\"text-decoration: underline;\"><strong>API 6D K\u00fcresel Vana ve API 609 kelebek vana tedarik\u00e7isi<\/strong><\/span>l\u00fctfen \u00e7ekinmeyin <span style=\"text-decoration: underline;\"><strong>bize Ula\u015f\u0131n<\/strong><\/span> e\u011fer onlara ihtiyac\u0131n varsa.<\/p>\n\n\n\n<p>\u00d6ncesi ve sonras\u0131yla on makale<\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/why-choose-butterfly-valve-api-6d-ball-valve-manufacturer.html\/\">Neden Kelebek Vanay\u0131 Se\u00e7melisiniz? | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/how-to-choose-a-globe-valve-and-how-does-it-work-api-6d-ball-valve-manufacturer.html\/\">K\u00fcresel Vana Nas\u0131l Se\u00e7ilir ve Nas\u0131l \u00c7al\u0131\u015f\u0131r? | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/news-zeco-valve-co-ltd-api-approved-valve-manufacturer.html\/\">Haberler \u2013 Zeco Valve Co., Ltd. | API onayl\u0131 valf \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/news-zeco-valve-company-won-the-quality-standard-zhejiang-manufacturing-certification-professional-valve-manufacturer.html\/\">Haberler \u2013 Zeco VALVE COMPANY \u201ckalite standard\u0131\u201d Zhejiang \u00fcretim sertifikas\u0131n\u0131 kazand\u0131 | Profesyonel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/news-forged-steel-globe-valve-professional-valve-manufacturer.html\/\">Haberler \u2013 d\u00f6vme \u00e7elik k\u00fcresel vana | Profesyonel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/a-guide-to-ball-valves2-api-6d-ball-valve-manufacturer.html\/\">K\u00fcresel Vana K\u0131lavuzu(2) | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/a-guide-to-ball-valves1-api-6d-ball-valve-manufacturer.html\/\">K\u00fcresel Vana K\u0131lavuzu(1) | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/single-seat-vs-cage-guided-globe-control-valve-api-6d-ball-valve-manufacturer.html\/\">Tekli Koltuk ve Kafes K\u0131lavuzlu K\u00fcre Kontrol Vanas\u0131 | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\/\">Kafes k\u0131lavuzlu valfin \u00f6zellikleri | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/knife-gate-valve-vs-gate-valve-api-6d-ball-valve-manufacturer.html\/\">B\u0131\u00e7ak S\u00fcrg\u00fcl\u00fc Vana VS S\u00fcrg\u00fcl\u00fc Vana | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>API \u2013 Amerikan Petrol Enstit\u00fcs\u00fc (K\u00fcresel Vana Standard\u0131) Boru hatt\u0131 vanalar\u0131 i\u00e7in API 6D Spesifikasyonu (K\u00fcresel, S\u00fcrg\u00fcl\u00fc, Plug ve \u00c7ek Valfler) API 6FA\u2026 <a title=\"API 6D K\u00fcresel Vana \u00dcreticisi \u2013 API 609 Kelebek Vana Tedarik\u00e7isi\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/tr\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\" aria-label=\"API 6D K\u00fcresel Vana \u00dcreticisi hakk\u0131nda daha fazlas\u0131 - API 609 Kelebek Vana Tedarik\u00e7isi\">Daha fazla bilgi edinin<\/a><\/p>","protected":false},"author":2,"featured_media":17518,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[2626,2376,2701,3246,3247,2700,3245],"class_list":["post-8930","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-api-609","tag-api-6d","tag-api-6d-ball-valve","tag-api-6d-ball-valves","tag-api-6d-valve","tag-api-6d-valves","tag-butterfly-valve-supplier","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/F-2-104945.jpg",800,600,false],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/tr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":2626,"name":"API 609","slug":"api-609","term_group":0,"term_taxonomy_id":2626,"taxonomy":"post_tag","description":"<!-- wp:kadence\/tableofcontents {\"uniqueID\":\"_9cda6c-35\"} \/-->\r\n\r\n<!-- wp:heading -->\r\n<h2 id=\"h-what-is-api-609-standard\">What is API 609 Standard?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThis standard covers design, materials, face-to-face dimensions, pressure-temperature ratings, and examination, inspection, and test requirements for gray iron, ductile iron, bronze, steel, nickel-based alloy, or special alloy butterfly valves.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe following two categories of butterfly valves are included:\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCategory A\u2014Manufacturer's rated cold working pressure (CWP) butterfly valves, usually with a concentric disc and seat configuration. Sizes covered are NPS 2 to NPS 60 for valves having ASME Class 125 or Class 150 flange bolting patterns.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCategory B\u2014ASME class and pressure-temperature-rated butterfly valves that have an offset seat and either an eccentric or a concentric disc configuration. Sizes covered are listed below:\r\nfor lug and wafer, Class 150 and 300: NPS 2 to NPS 60;\r\nfor lug and wafer, Class 600: NPS 3 to NPS 60;\r\nfor double-flanged short and long pattern, Class 150, 300, and 600: NPS 3 to NPS 60;\r\nfor butt-welding ends, Class 150, 300 and 600: NPS 3 to 60;\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>What is an API 609 Butterfly Valve?<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe API 609 butterfly valve is used to shut off or modulate the flow of a fluid (isolation and regulation). API 609 Centric butterfly valves (soft seated) are preferred to gate and ball valves for low-pressure and non-critical applications as they are cheaper, lighter, and easier to install. Eccentric butterfly valves (double offset and triple offset valves) with metal seats have surged in popularity and compete with globe and ball valves for some applications.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:generateblocks\/button-container {\"uniqueId\":\"6d8495a3\",\"isDynamic\":true,\"blockVersion\":2} -->\r\n<!-- wp:generateblocks\/button {\"uniqueId\":\"3d442e11\",\"hasUrl\":true,\"target\":true,\"backgroundColor\":\"#0366d6\",\"textColor\":\"#ffffff\",\"backgroundColorHover\":\"#222222\",\"textColorHover\":\"#ffffff\",\"paddingTop\":\"15\",\"paddingRight\":\"20\",\"paddingBottom\":\"15\",\"paddingLeft\":\"20\"} -->\r\n<a class=\"gb-button gb-button-3d442e11 gb-button-text\" href=\"mailto:commercial@zecovalve.com\" target=\"_blank\" rel=\"noopener noreferrer\"><strong>GET API 609 BUTTERFLY VALVE PRICE<\/strong><\/a>\r\n<!-- \/wp:generateblocks\/button -->\r\n<!-- \/wp:generateblocks\/button-container -->\r\n\r\n<!-- wp:heading -->\r\n<h2>API 609 Butterfly Valve Working Principle<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nThe key component of a butterfly valve is the disc, a metal ring that is positioned at the centerline of the pipe and connected to an external actuator (manual level or actuator) via a rod.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nCompared to a ball valve, the disc of a butterfly valve is always in contact with the fluid conveyed by the pipeline and creates, therefore, a pressure drop.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nIn the closed position, the disc blocks the bore of the valve, and, in an open position, the disc allows the passage of the fluid.\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nA quarter turn movement is needed to switch the valve from a fully open to a fully closed position (and such movement can be executed as quickly as for ball valves).\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:heading -->\r\n<h2>Specifications of API 609 Butterfly Valve<\/h2>\r\n<!-- \/wp:heading -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nFace to Face Dimensions: ANSI B16.10\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nFlange end Dimension: ANSI B16.5\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nButt Welded Dimensions: ANSI B16.25\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nDesign and Manufacture: API 609\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nPressure Test: API598\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nMaterials\uff1aWCB \u3001WC6 \u3001WC9 \u3001CF8\u3001 CF8M\u3001 CF3\u3001 CF3M \u3001CN7M\u3001LC1\r\n\r\n<!-- \/wp:paragraph -->\r\n\r\n<!-- wp:paragraph -->\r\n\r\nLC2\u3001LC3\u3001LCB\u3001LCC\u3001Monel\u300120# Alloys\u30014A\u30015A\u3001C95800\u3001C95500, etc.\r\n\r\n<!-- \/wp:paragraph -->","parent":0,"count":5,"filter":"raw"},{"term_id":2376,"name":"API 6D","slug":"api-6d","term_group":0,"term_taxonomy_id":2376,"taxonomy":"post_tag","description":"","parent":0,"count":8,"filter":"raw"},{"term_id":2701,"name":"API 6D Ball Valve","slug":"api-6d-ball-valve","term_group":0,"term_taxonomy_id":2701,"taxonomy":"post_tag","description":"","parent":0,"count":7,"filter":"raw"},{"term_id":3246,"name":"api 6d ball valves","slug":"api-6d-ball-valves","term_group":0,"term_taxonomy_id":3246,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":3247,"name":"api 6d valve","slug":"api-6d-valve","term_group":0,"term_taxonomy_id":3247,"taxonomy":"post_tag","description":"","parent":0,"count":3,"filter":"raw"},{"term_id":2700,"name":"API 6D Valves","slug":"api-6d-valves","term_group":0,"term_taxonomy_id":2700,"taxonomy":"post_tag","description":"","parent":0,"count":5,"filter":"raw"},{"term_id":3245,"name":"butterfly valve supplier","slug":"butterfly-valve-supplier","term_group":0,"term_taxonomy_id":3245,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":2626,"label":"API 609"},{"value":2376,"label":"API 6D"},{"value":2701,"label":"API 6D Ball Valve"},{"value":3246,"label":"api 6d ball valves"},{"value":3247,"label":"api 6d valve"},{"value":2700,"label":"API 6D Valves"},{"value":3245,"label":"butterfly valve supplier"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>API 6D Ball Valve Manufacturer - API 609 Butterfly Valve Supplier | ZECO<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/tr\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"API 6D Ball Valve Manufacturer - API 609 Butterfly Valve Supplier | ZECO\" \/>\n<meta property=\"og:description\" content=\"API &#8211; American Petroleum Institute (Ball Valve Standard) API 6D Specification for pipeline valves (Ball, Gate, Plug and Check Valves) API 6FA ... Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/tr\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-30T08:01:27+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-07-25T13:39:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/F-2-104945.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"600\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\">\n\t<meta name=\"twitter:data2\" content=\"5 dakika\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"tr\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html#primaryimage\",\"inLanguage\":\"tr\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/06\/F-2-104945.jpg\",\"width\":800,\"height\":600,\"caption\":\"Cast Steel Trunnion Ball Valve\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\",\"name\":\"API 6D Ball Valve Manufacturer - API 609 Butterfly Valve Supplier | ZECO\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html#primaryimage\"},\"datePublished\":\"2021-12-30T08:01:27+00:00\",\"dateModified\":\"2022-07-25T13:39:20+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\",\"url\":\"https:\/\/zecovalve.com\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\",\"name\":\"API 6D Ball Valve Manufacturer &#8211; API 609 Butterfly Valve Supplier\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/8930","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/comments?post=8930"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/8930\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/media\/17518"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/media?parent=8930"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/categories?post=8930"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/tags?post=8930"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}