{"id":8942,"date":"2021-12-30T08:01:38","date_gmt":"2021-12-30T08:01:38","guid":{"rendered":"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html"},"modified":"2022-12-29T08:28:07","modified_gmt":"2022-12-29T08:28:07","slug":"features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer","status":"publish","type":"post","link":"https:\/\/zecovalve.com\/tr\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html","title":{"rendered":"Kafes K\u0131lavuzlu Vanan\u0131n \u00d6zellikleri \u2013 Kafes Vana"},"content":{"rendered":"<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-1024x768.jpg\" alt=\"\" class=\"wp-image-26426\" width=\"512\" height=\"384\" srcset=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-1024x768.jpg 1024w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-300x225.jpg 300w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-768x576.jpg 768w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-1536x1152.jpg 1536w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-2048x1536.jpg 2048w, https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-600x450.jpg 600w\" sizes=\"auto, (max-width: 512px) 100vw, 512px\" \/><\/figure>\n<\/div>\n\n\n\n\n<h2 class=\"wp-block-heading\">Kafes Vana Nedir?<\/h2>\n\n\n\n<p>K\u00fcresel vana tasar\u0131m\u0131n\u0131n daha modern bir versiyonu, i\u00e7ine d\u00f6k\u00fclm\u00fc\u015f veya i\u015flenmi\u015f portlara sahip \u00e7evreleyen bir kafes i\u00e7inde piston \u015feklinde bir tapa kullan\u0131r.<\/p>\n\n\n\n<p>Bu kafes k\u0131lavuzlu glob vanalar, tapa yukar\u0131 ve a\u015fa\u011f\u0131 hareket ettik\u00e7e \u00e7evreleyen kafesteki port alan\u0131n\u0131n daha fazlas\u0131n\u0131 veya daha az\u0131n\u0131 a\u00e7arak ak\u0131\u015f\u0131 k\u0131sar. Kafes ayn\u0131 zamanda tapaya k\u0131lavuzluk eder, b\u00f6ylece milin mil k\u0131lavuzlu vana tasar\u0131m\u0131nda oldu\u011fu gibi yanal kuvvetlere maruz kalmas\u0131 gerekmez.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Kafes K\u0131lavuzlu Vanan\u0131n \u00d6zellikleri<\/h2>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Boyut\n<ul class=\"wp-block-list\">\n<li>2\u201d ila 24\u201d (50 ila 600 mm)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Derecelendirmeler ve Ba\u011flant\u0131lar\n<ul class=\"wp-block-list\">\n<li>Flan\u015fl\u0131: ANSI 150 \u2013 2500, UNI-DIN 10 \u2013 400<\/li>\n\n\n\n<li>Kaynakl\u0131: BW veya SW<\/li>\n\n\n\n<li>Vidal\u0131: NPT 2\u201d (50 mm)<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>G\u00f6vde Malzemeleri\n<ul class=\"wp-block-list\">\n<li>Karbon \u00e7elik; paslanmaz \u00e7elik; krom-moly<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>D\u00f6\u015feme\n<ul class=\"wp-block-list\">\n<li>Dengeli kafes k\u0131lavuzlu kaplama; Lo-dB, kavitasyon \u00f6nleyici ve VRT (De\u011fi\u015fken Diren\u00e7 Trimi), tekli ve \u00e7oklu kafesler mevcuttur<\/li>\n<\/ul>\n<\/li>\n\n\n\n<li>Do\u011fal \u00d6zellikler\n<ul class=\"wp-block-list\">\n<li>do\u011frusal veya e\u015fit y\u00fczde<\/li>\n<\/ul>\n<\/li>\n<\/ul>\n\n\n\n<h2 class=\"wp-block-heading\" id=\"h-features-of-the-cage-guided-valve\">Kafes K\u0131lavuzlu vanan\u0131n \u00f6zellikleri<\/h2>\n\n\n\n<p>Kafes k\u0131lavuzlu vanalar bir\u00e7ok avantaj\u0131ndan dolay\u0131 yayg\u0131n olarak kullan\u0131lmaktad\u0131r. Gelin onlar hakk\u0131nda daha fazlas\u0131n\u0131 birlikte \u00f6\u011frenelim.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-1-easy-to-change-the-flow-characteristics\">1. Ak\u0131\u015f \u00f6zelliklerini de\u011fi\u015ftirmek kolayd\u0131r.<\/h3>\n\n\n\n<p>Man\u015fon ayar vanas\u0131, ak\u0131\u015fkan\u0131n man\u015fondan d\u0131\u015far\u0131 do\u011fru ak\u0131\u015f\u0131na, merkezden d\u0131\u015far\u0131ya ak\u0131\u015f y\u00f6n\u00fcne do\u011fru denir. Tersine, ak\u0131\u015f merkezin d\u0131\u015f\u0131nda olarak adland\u0131r\u0131l\u0131r. Ancak genellikle man\u015fonun alt k\u0131sm\u0131ndan kafesin a\u00e7\u0131kl\u0131\u011f\u0131ndan d\u0131\u015far\u0131 akmas\u0131 i\u00e7in kullan\u0131l\u0131r. Man\u015fonda simetrik olarak yerle\u015ftirilmi\u015f 3, 4 veya 6 adet gaz kelebe\u011fi a\u00e7\u0131kl\u0131\u011f\u0131 vard\u0131r. Gaz kelebe\u011fi a\u00e7\u0131kl\u0131klar\u0131n\u0131n \u015fekli istenen ak\u0131\u015f \u00f6zellikleriyle ilgilidir. Bu nedenle kontrol valfinin ak\u0131\u015f \u00f6zellikleri, man\u015fon (gaz kelebe\u011fi a\u00e7\u0131kl\u0131\u011f\u0131n\u0131n \u015fekli) de\u011fi\u015ftirilerek kolayca de\u011fi\u015ftirilebilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-2-easy-to-install-and-maintain\">2. Kurulumu ve bak\u0131m\u0131 kolayd\u0131r.&nbsp;<\/h3>\n\n\n\n<p>Valf yuvas\u0131, valf kapa\u011f\u0131 taraf\u0131ndan valf g\u00f6vdesine do\u011fru bast\u0131r\u0131l\u0131r ve vidalanmaz. Kurulumu ve bak\u0131m\u0131 kolay.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-3-interchangeability-and-versatility\">3. De\u011fi\u015ftirilebilirlik ve \u00e7ok y\u00f6nl\u00fcl\u00fck.&nbsp;<\/h3>\n\n\n\n<p>Farkl\u0131 man\u015fonlar de\u011fi\u015ftirilerek farkl\u0131 ak\u0131\u015f katsay\u0131lar\u0131 ve farkl\u0131 ak\u0131\u015f \u00f6zellikleri elde edilebilir.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-4-noise-reduction\">4. G\u00fcr\u00fclt\u00fc azaltma.&nbsp;<\/h3>\n\n\n\n<p>Kontrol vanas\u0131 g\u00fcr\u00fclt\u00fcs\u00fcn\u00fc azaltmak i\u00e7in man\u015fonlu kontrol vanalar\u0131 g\u00fcr\u00fclt\u00fcy\u00fc azaltan i\u00e7 par\u00e7alara sahip tip olarak mevcuttur. Bir dizi k\u00fc\u00e7\u00fck deli\u011fe sahip bir man\u015fonu ve makaras\u0131 vard\u0131r. K\u00fc\u00e7\u00fck delikler direnci artt\u0131rmak i\u00e7in kullan\u0131l\u0131r. G\u00fcr\u00fclt\u00fcy\u00fc azaltmak i\u00e7in h\u0131z ba\u015fl\u0131\u011f\u0131 kinetik enerjiye d\u00f6n\u00fc\u015ft\u00fcr\u00fcl\u00fcr. Tipik olarak bu tip man\u015fonlu kontrol vanas\u0131 g\u00fcr\u00fclt\u00fcy\u00fc 10 dB&#039;den fazla azaltabilir.<\/p>\n\n\n\n<p>Bu nedenle g\u00fcr\u00fclt\u00fcn\u00fcn azalt\u0131lmas\u0131n\u0131n gerekli oldu\u011fu uygulamalarda yayg\u0131n olarak kullan\u0131l\u0131rlar. Kontrol vanas\u0131 g\u00fcr\u00fclt\u00fcs\u00fcn\u00fc azaltmak i\u00e7in \u00e7ok a\u015famal\u0131 bas\u0131n\u00e7 d\u00fc\u015f\u00fcrme y\u00f6ntemleri de kullan\u0131labilir. Bu g\u00fcr\u00fclt\u00fc azalt\u0131c\u0131 kontrol vanalar\u0131n\u0131n her iki ucundaki toplam bas\u0131n\u00e7 d\u00fc\u015f\u00fc\u015f\u00fc t\u00fcm seviyelere da\u011f\u0131t\u0131l\u0131r, b\u00f6ylece t\u00fcm seviyeler ak\u0131\u015fkan\u0131n yan\u0131p s\u00f6nmesine ve kavitasyona neden olmaz.<\/p>\n\n\n\n<p>Bu, g\u00fcr\u00fclt\u00fcy\u00fc azalt\u0131r <span style=\"text-decoration: underline;\">kontrol vanas\u0131<\/span> ve parlama ve kavitasyonun neden oldu\u011fu a\u015f\u0131nmay\u0131 ve a\u015f\u0131nmay\u0131 zay\u0131flatabilir ve \u00f6nleyebilir. Man\u015fon kontrol valfinin makaras\u0131n\u0131n alt k\u0131sm\u0131 d\u00fczd\u00fcr, b\u00f6ylece kavitasyon meydana gelirse kabarc\u0131\u011f\u0131n patlamas\u0131ndan kaynaklanan etki makara \u00fczerinde etkili olmaz, ancak ortam\u0131n kendisi taraf\u0131ndan emilir. Bu nedenle, man\u015fon ayar valfindeki kavitasyonun etkisi k\u00fc\u00e7\u00fckt\u00fcr ve servis \u00f6mr\u00fc uzundur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-5-leakage-is-larger-than-single-seated-valves\">5. S\u0131z\u0131nt\u0131 tek yatakl\u0131 vanalara g\u00f6re daha fazlad\u0131r.&nbsp;<\/h3>\n\n\n\n<p>Man\u015fon ve grafit piston segman\u0131 contas\u0131 aras\u0131ndaki makara sonucunda. Uzun s\u00fcreli \u00e7al\u0131\u015fmadan sonra conta halkas\u0131n\u0131n a\u015f\u0131nmas\u0131, man\u015fon ayar vanas\u0131n\u0131n s\u0131z\u0131nt\u0131s\u0131n\u0131n tek yatakl\u0131 vanan\u0131nkinden daha b\u00fcy\u00fck olmas\u0131na neden olur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-6-easy-maintenance\">6. Kolay bak\u0131m.&nbsp;<\/h3>\n\n\n\n<p>Ters man\u015fonlu kontrol vanas\u0131, makara alttan \u00e7\u0131kar\u0131labildi\u011finden, vana i\u00e7 k\u0131s\u0131mlar\u0131n\u0131n s\u0131k s\u0131k muayene ve bak\u0131m gerektirdi\u011fi uygulamalar i\u00e7in \u00f6zellikle uygundur.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\" id=\"h-7-reduces-the-impact-of-unbalanced-forces\">7. Dengesiz kuvvetlerin etkisini azalt\u0131r.&nbsp;<\/h3>\n\n\n\n<p>Genellikle iki tip man\u015fon ayar vanas\u0131 vard\u0131r; biri dengeli vana, di\u011feri ise dengesiz vanad\u0131r. Dengeleme valfinin makara \u00fczerinde bir dengeleme deli\u011fi bulunur, b\u00f6ylece makara \u00fczerindeki dengesizlik kuvveti b\u00fcy\u00fck \u00f6l\u00e7\u00fcde azalt\u0131l\u0131r. Ayn\u0131 zamanda kontrol vanas\u0131n\u0131n kararl\u0131 \u00e7al\u0131\u015fmas\u0131na faydal\u0131 olan bir s\u00f6n\u00fcmleme etkisine sahiptir. Bu nedenle bu tip kontrol vanalar\u0131 genellikle y\u00fcksek fark bas\u0131nc\u0131 ve d\u00fc\u015f\u00fck g\u00fcr\u00fclt\u00fc gereksinimleri olan uygulamalarda kullan\u0131l\u0131r.<\/p>\n\n\n\n<p>Biz <span style=\"text-decoration: underline;\"><strong>kafes valf tedarik\u00e7isi<\/strong><\/span>, ihtiyac\u0131n\u0131z varsa l\u00fctfen bizimle ileti\u015fime ge\u00e7mekten \u00e7ekinmeyin.<\/p>\n\n\n\n<!-- Andy:h-related-tags -->\n<h2 id=\"h-related-tags\">\u0130lgili Etiketler :<\/h2>\n<!-- \/Andy:h-related-tags -->\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/\">ZECO Valf<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/gate-valve-problems.html\/\">S\u00fcrg\u00fcl\u00fc Vana Onar\u0131m\u0131<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/the-function-of-globe-valve-in-pipeline-system.html\/\">Glob Vanalar Nedir?<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/tag\/shanghai-pressure-reducing-valve-factory\/\">\u015eangay Bas\u0131n\u00e7 D\u00fc\u015f\u00fcr\u00fcc\u00fc Vana Fabrikas\u0131<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/urun\/12-inch-gate-valve\/\">12 in\u00e7 S\u00fcrg\u00fcl\u00fc Vana Tedarik\u00e7isi<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/urun-kategori%cc%87si%cc%87\/ball-valve\/\">K\u00fcresel Vana \u00dcreticisi \u2013 \u00c7e\u015fitli K\u00fcresel Vana Tipleri<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/urun-kategori%cc%87si%cc%87\/butterfly-valve\/\">Kelebek Vana \u00dcreticisi \u2013 \u00c7e\u015fitli Kelebek Vana \u00c7e\u015fitleri<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/product-tag\/swing-check-valve\/\">Swing \u00c7ek Valf \u2013 \u00c7e\u015fitli \u00c7ek Valf Tipleri<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/product-tag\/ball-valve-price\/\">Rekabet\u00e7i K\u00fcresel Vana Fiyat\u0131 \u2013 K\u00fcresel Vana \u00dcreticisi<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/product-tag\/motorized-valve\/\">Motorlu Vana \u2013 Motorlu S\u00fcrg\u00fcl\u00fc Vana \/ K\u00fcresel Vana<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/product-tag\/ball-valve-stainless-steel\/\">K\u00fcresel Vana Paslanmaz \u00c7elik \u2013 Paslanmaz \u00c7elik K\u00fcresel Vana<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/product-tag\/wafer-check-valve\/\">Wafer \u00c7ek Valf \u2013 API 594 \u00c7ek Valf \u00dcreticisi<\/a>\n\n<\/div>\n\n\n\n<div class=\"re_main\">\n<a href=\"https:\/\/zecovalve.com\/tr\/what-is-an-air-valve-air-valve-types-air-release-valve.html\/\">Hava Valfi Nedir? Hava Valfi \u00c7e\u015fitleri \u2013 Hava Tahliye Valfi<\/a>\n\n<\/div>\n\n\n\n<p>\u00d6ncesi ve sonras\u0131yla on makale<\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/single-seat-vs-cage-guided-globe-control-valve-api-6d-ball-valve-manufacturer.html\/\">Tekli Koltuk ve Kafes K\u0131lavuzlu K\u00fcre Kontrol Vanas\u0131 | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/a-guide-to-ball-valves1-api-6d-ball-valve-manufacturer.html\/\">K\u00fcresel Vana K\u0131lavuzu(1) | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/a-guide-to-ball-valves2-api-6d-ball-valve-manufacturer.html\/\">K\u00fcresel Vana K\u0131lavuzu(2) | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/when-is-a-butterfly-valve-used-api-6d-ball-valve-manufacturer.html\/\">Kelebek Vana Ne Zaman Kullan\u0131l\u0131r? | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/why-choose-butterfly-valve-api-6d-ball-valve-manufacturer.html\/\">Neden Kelebek Vanay\u0131 Se\u00e7melisiniz? | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/knife-gate-valve-vs-gate-valve-api-6d-ball-valve-manufacturer.html\/\">B\u0131\u00e7ak S\u00fcrg\u00fcl\u00fc Vana VS S\u00fcrg\u00fcl\u00fc Vana | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/are-the-valves-closed-clockwise-and-opened-counterclockwise-api-6d-ball-valve-manufacturer.html\/\">Vanalar saat y\u00f6n\u00fcnde kapal\u0131 m\u0131, saat y\u00f6n\u00fcn\u00fcn tersine mi a\u00e7\u0131l\u0131yor? | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/should-we-use-a-soft-seal-or-a-hard-seal-for-the-butterfly-valve-api-6d-ball-valve-manufacturer.html\/\">Kelebek Vana \u0130\u00e7in Yumu\u015fak Conta m\u0131 Yoksa Sert Conta m\u0131 Kullanmal\u0131y\u0131z? | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/factors-affecting-the-sealing-performance-of-globe-control-valves-api-6d-ball-valve-manufacturer.html\/\">Glob Kontrol Vanalar\u0131n\u0131n S\u0131zd\u0131rmazl\u0131k Performans\u0131n\u0131 Etkileyen Fakt\u00f6rler | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>\n\n\n\n<p><a href=\"https:\/\/zecovalve.com\/tr\/difference-between-gate-valve-and-butterfly-valve-api-6d-ball-valve-manufacturer.html\/\">S\u00fcrg\u00fcl\u00fc Vana ve Kelebek Vana Aras\u0131ndaki Fark | API 6D k\u00fcresel vana \u00fcreticisi<\/a><\/p>","protected":false},"excerpt":{"rendered":"<p>Kafes Vana Nedir? K\u00fcresel vana tasar\u0131m\u0131n\u0131n daha modern bir versiyonu, etraf\u0131n\u0131 saran bir kafesin i\u00e7inde piston \u015feklinde bir tapa kullan\u0131r. <a title=\"Kafes K\u0131lavuzlu Vanan\u0131n \u00d6zellikleri \u2013 Kafes Vana\" class=\"read-more\" href=\"https:\/\/zecovalve.com\/tr\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\" aria-label=\"Kafes K\u0131lavuzlu Vanan\u0131n \u00d6zellikleri Hakk\u0131nda Daha Fazla Bilgi \u2013 Kafes Vana\">Daha fazla bilgi edinin<\/a><\/p>","protected":false},"author":2,"featured_media":26426,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_generate-full-width-content":"","kt_blocks_editor_width":"","footnotes":""},"categories":[1],"tags":[3982,3981,3980],"class_list":["post-8942","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-uncategorized","tag-cage-guided-globe-valve","tag-cage-guided-valve","tag-cage-valve","generate-columns","tablet-grid-50","mobile-grid-100","grid-parent","grid-50"],"featured_image_src_large":["https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-1024x768.jpg",1024,768,true],"author_info":{"display_name":"Jerry","author_link":"https:\/\/zecovalve.com\/tr\/author\/jerry"},"comment_info":0,"category_info":[{"term_id":1,"name":"Uncategorized","slug":"uncategorized","term_group":0,"term_taxonomy_id":1,"taxonomy":"category","description":"","parent":0,"count":452,"filter":"raw","cat_ID":1,"category_count":452,"category_description":"","cat_name":"Uncategorized","category_nicename":"uncategorized","category_parent":0}],"tag_info":[{"term_id":3982,"name":"Cage Guided Globe Valve","slug":"cage-guided-globe-valve","term_group":0,"term_taxonomy_id":3982,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3981,"name":"Cage Guided Valve","slug":"cage-guided-valve","term_group":0,"term_taxonomy_id":3981,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"},{"term_id":3980,"name":"Cage Valve","slug":"cage-valve","term_group":0,"term_taxonomy_id":3980,"taxonomy":"post_tag","description":"","parent":0,"count":1,"filter":"raw"}],"taxonomy_info":{"category":[{"value":1,"label":"Uncategorized"}],"post_tag":[{"value":3982,"label":"Cage Guided Globe Valve"},{"value":3981,"label":"Cage Guided Valve"},{"value":3980,"label":"Cage Valve"}]},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v15.4 - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Features of Cage Guided Valve - Cage Valve | ZECO Valve<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/zecovalve.com\/tr\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Features of Cage Guided Valve - Cage Valve | ZECO Valve\" \/>\n<meta property=\"og:description\" content=\"What is Cage Valve? A more modern version of the globe valve design uses a piston-shaped plug inside a surrounding cage with ... Read more\" \/>\n<meta property=\"og:url\" content=\"https:\/\/zecovalve.com\/tr\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\" \/>\n<meta property=\"og:site_name\" content=\"ZECO Valve\" \/>\n<meta property=\"article:published_time\" content=\"2021-12-30T08:01:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-12-29T08:28:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-scaled.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"2560\" \/>\n\t<meta property=\"og:image:height\" content=\"1920\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\">\n\t<meta name=\"twitter:data1\" content=\"Jerry\">\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\">\n\t<meta name=\"twitter:data2\" content=\"3 dakika\">\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/zecovalve.com\/#website\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"ZECO Valve\",\"description\":\"Industrial Ball Valve, Gate Valve and Globe Valve Manufacturer\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":\"https:\/\/zecovalve.com\/?s={search_term_string}\",\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"tr\"},{\"@type\":\"ImageObject\",\"@id\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html#primaryimage\",\"inLanguage\":\"tr\",\"url\":\"https:\/\/zecovalve.com\/wp-content\/uploads\/2022\/08\/Control-Valve-0-scaled.jpg\",\"width\":2560,\"height\":1920},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html#webpage\",\"url\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\",\"name\":\"Features of Cage Guided Valve - Cage Valve | ZECO Valve\",\"isPartOf\":{\"@id\":\"https:\/\/zecovalve.com\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html#primaryimage\"},\"datePublished\":\"2021-12-30T08:01:38+00:00\",\"dateModified\":\"2022-12-29T08:28:07+00:00\",\"author\":{\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\"},\"breadcrumb\":{\"@id\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/\",\"url\":\"https:\/\/zecovalve.com\/\",\"name\":\"Home\"}},{\"@type\":\"ListItem\",\"position\":2,\"item\":{\"@type\":\"WebPage\",\"@id\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\",\"url\":\"https:\/\/zecovalve.com\/features-of-the-cage-guided-valve-api-6d-ball-valve-manufacturer.html\",\"name\":\"Features of Cage Guided Valve &#8211; Cage Valve\"}}]},{\"@type\":\"Person\",\"@id\":\"https:\/\/zecovalve.com\/#\/schema\/person\/f65555145e0ef282ff87649309aba6a3\",\"name\":\"Jerry\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","_links":{"self":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/8942","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/comments?post=8942"}],"version-history":[{"count":0,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/posts\/8942\/revisions"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/media\/26426"}],"wp:attachment":[{"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/media?parent=8942"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/categories?post=8942"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zecovalve.com\/tr\/wp-json\/wp\/v2\/tags?post=8942"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}