Attention to Dynamic Balancing Valve in Air Conditioning System Design
1. Dynamic balancing valve only plays the role of hydraulic balance and cannot be used for load regulation. Because of the misunderstanding … Read more
To meet the growing use of variable speed pumps for HVAC applications, ZECO Fluid Systems has launched a range of Differential Pressure Control Valves (DPCV) specifically aimed at optimizing system performance.
Extremely efficient, the DPCV is set to a maximum differential pressure which ensures flow cannot exceed the desired rate. It, therefore, helps reduce energy consumption, and the risk of noise and simplifies the commissioning process.
Differential Pressure Control Valves – also commonly called DPCVs – are installed in heating or cooling systems to control sub-circuit pressure to a set or given maximum.
ZECO’s DPCV range includes three different types. A type with pre-set ΔpC (differential pressure across the circuit), a type with adjustable ΔpC, and finally a type being a combined dynamic balancing valve and adjustable DPCV. They offer a flexible range meeting any system demand.
A differential pressure controller consists of a valve and a pressure actuator. Differential pressure controllers in the primary system are mainly used to keep a constant and lower differential pressure across a motorized control valve or a total system/substation.
With a DPCV installed in Your system, You will achieve reduced energy consumption, avoid the risk of annoying noise and have a simple commissioning process.
A DPCV includes a diaphragm, a spring, and a capillary tube connecting the partner valve in the supply pipe and the DPCV valve in the return pipe to control the circuit pressure loss.
The differential pressure control valve (DPCV) is a special kind of control valve whose action is related to a measured pressure difference. In practice, the DPCV is used in several applications as will be further explained basically, its goal is to maintain a constant pressure difference across a certain part of the hydraulic network. Inside the DPCV, two cavities are separated by means of a membrane. One cavity is internally connected to the upstream side of the DPCV while the other one is connected to a remote location by means of a small capillary pipe. This way, the differential pressure across the membrane equals the pressure difference between the upstream measuring point and the DPCV. The resulting spindle travel depends on the force balance between the membrane and the spring.
• ΔP Control
The DPCV diaphragm will regulate to control ΔpC (differential pressure across the circuit) depending on pressure impulse from the supply side and direct pressure from the return side. The spring force will equal the ΔpC.
In all ZECO DPCVs, the diaphragm will be a rolling diaphragm which will result in a very compact valve design. Depending on the ZECO Differential Pressure Control Valve selected, ΔpC may be fixed or externally adjustable.
1. Dynamic balancing valve only plays the role of hydraulic balance and cannot be used for load regulation. Because of the misunderstanding … Read more
1. The dynamic balancing valve has good balancing function The dynamic balancing valve can balance the system flow automatically at the required … Read more
The dynamic balancing valve can change the spool according to the pressure difference of the water system from time to time, ensuring that the … Read more
No matter heating or air conditioning project, it is impossible to use the same journey system because of condition restrictions. In actual … Read more
The dynamic flow balancing valve allows the valve to change according to the pressure difference of the water system from time to … Read more
The common types of balancing valves in HVAC systems are mainly static hydraulic balancing valves for eliminating static hydraulic imbalance and realizing … Read more
1. Installation location of Auto Balancing Valve The auto balancing valve can be installed in the water supply pipeline or in the … Read more
To meet the growing use of variable speed pumps for HVAC applications, Hattersley has launched a range of Differential Pressure Control Valves … Read more
Function of Dynamic Flow Balancing Valves: The dynamic flow balance valve keeps the flow constant between 31-600KPa. Role of Dynamic Flow Balancing … Read more
Dynamic flow balancing valves are also known as pressure independent control valves (PICV) , self-operated balancing valves, constant flow valves, and automatic … Read more